Hager ADM425T 25A RCBO Safety Switch 4 Pole (3P+N) 30mA Type A 6kA C Curve 230-415V AC 4 Module DIN Rail

SKU: hagrcb425

Product Image Gallery

Product image thumbnail for SKU hagrcb425

Product Pricing

$170.63 (ex-GST)

$187.69 (inc-GST)

$187.69

$170.63

(inc-GST)
(ex-GST)

Stock and Availability

  • ⚫︎ Ships in 24 hours

Hager ADM425T RCBO rated 25A with four protected poles (3P+N). Combines C curve overload and short-circuit tripping with 30mA Type A residual current protection. 6kA Icn and Ics, 230-415V AC, 4 modules, IP2X, right-hand neutral, DIN rail mounting.

Electrotraders USPs

Fast Shipping, Trusted by Government, Easy Returns, Free Shipping over $200


Description

A 25A three-phase breaker with built-in safety switch.

The ADM425T from Hager is a 4 module RCBO carrying a 25A rating across three phases plus neutral. It trips on overload, short-circuit or 30mA earth leakage, giving every protected circuit its own independent residual current device without adding a separate RCD to the board.

Key Features

  • Nominal current: 25A
  • Characteristic: curve C
  • Residual sensitivity: 30mA, Type A
  • Configuration: 3P+N, 4 protected poles, neutral right
  • Breaking capacity: 6kA Icn, 6kA Ics to IEC 60898-1
  • Voltage: 230-415V AC at 50Hz
  • Size: 4 modules, 71mm W x 84mm H x 70mm D
  • Biconnect bottom terminal, DIN rail mounting
  • Energy limitation class 3, IP2X protection

Get yours today – ships in 24 hours with delivery right across Australia.

 

How the Hager ADM425T Protects a 25A Circuit

Two devices in one housing
An RCBO is a residual current operated circuit breaker with integral overcurrent protection. In the ADM425T, the overcurrent section handles sustained overloads and short-circuits up to its 6kA rating, while the residual current section disconnects the circuit if current leaking to earth reaches 30mA. For three-phase boards, that means no shared RCD grouping and less disruption when a single circuit faults.

What Type A and C curve mean in practice
Type A sensing picks up alternating and pulsating direct earth fault currents. Curve C sets the magnetic trip point higher than curve B, giving tolerance to switch-on surges from mixed or inductive loads. Together with I²t class 3 energy limitation, these ratings define how the device behaves under fault.

Sizing and installation data

  • Temperature derating: 25A at 30°C, 23.6A at 40°C, 22A at 50°C, 20.4A at 60°C.
  • Side-by-side mounting of two devices: apply a 0.80 correction factor.
  • Heat output: 12.3W power dissipation at rated current.
  • Terminal capacity: 1-16mm² flexible or 1-25mm² solid conductors, 2Nm torque.
  • Installation by a licensed electrician in line with the AS/NZS 3000 Wiring Rules.

Q: What is the Hager ADM425T?
A: It is a Hager 25A, 4 pole (3P+N) RCBO with a C tripping curve, 30mA Type A earth leakage protection and a 6kA breaking capacity, occupying 4 DIN rail modules.

Q: Does the Hager ADM425T need a separate RCD?
A: No. Earth leakage protection at 30mA is built into the ADM425T, so the circuit it feeds does not need an additional upstream RCD for that function.

Q: What is the operating temperature range of the Hager ADM425T?
A: Hager specifies an operating temperature of -25 to 40°C, with storage and transport rated from -55 to 70°C.

(hagrcb425)

Specifications

Electric current
Rated current25 A
Rated residual operating current Idn30 mA
Rated current -25DegC31,70 A
Rated current at -20DegC31,20 A
Rated current -15DegC30,60 A
Rated current -10DegC30 A
Rated current -5DegC29,40 A
Rated current at 0DegC28,90 A
Rated current 5DegC28,30 A
Rated current 10DegC27,60 A
Rated current 15DegC27 A
Rated current at 20DegC26,40 A
Rated current 25DegC25,70 A
Rated current 30DegC25 A
Rated current 35DegC24,30 A
Rated current at 40DegC23,60 A
Rated current at 45DegC22,80 A
Rated current at 50DegC22 A
Rated current 55DegC21,20 A
Rated current 60DegC20,40 A
Rated short-circuit breaking capacity Icn under 230 V AC according to IEC 61009-16 kA
Architecture
CurveC
Neutral positionRight
Type of pole4P
Number of protected poles4
Capacity
Number of modules4
Safety
Residual current typeA
Ingress Protection (IP) classIP2X
Voltage
Type voltage supplyAC
Rated operational voltage Ue230 - 415 V
Rated insulation voltage Ui500 V
Dielectric strength value of power frequency2 kV
Rated impulse withstand voltage Uimp4000 V
Overvoltage category according to IEC 60947-13
Installation, mounting
Nominal tightening torque top terminal2 - 2 Nm
Nominal tightening torque down terminal2 - 2 Nm
Nominal tightening torque2 - 2 Nm
360?ø mounting position possibleYes
Type of top connection for modular devicesScrew terminal
Type of bottom connection for modular devicesbiconnect, Bypass
Main electrical attributes
Rated short-circuit breaking capacity Icn AC according to IEC 60898-16 kA
Frequency
Frequency50 - 50 Hz
Connection
Cross-section of input with screws, for flexible conductors1 - 16 mm^2
Cross-section of input with screws, for massive conductors1 - 25 mm^2
Use conditions
Class of energy limitation I^2t3
Operating temperature-25 - 40 DegC
Dimensions
Height84 mm
Width71 mm
Depth70 mm
Power
Total power loss under IN12,30 W
SKU hagrcb425
Manfacturer Part Number ADM425T
Barcode # 3250611032960
Brand Hager

Shipping Calculator