Hager ADM420T 20A 4 Pole (3P+N) RCBO Safety Switch 6kA C Curve 30mA Type A 230-415V AC 4 Module DIN Rail

SKU: hagrcb420

Product Image Gallery

Product image thumbnail for SKU hagrcb420

Product Pricing

$170.63 (ex-GST)

$187.69 (inc-GST)

$187.69

$170.63

(inc-GST)
(ex-GST)

Stock and Availability

  • ⚫︎ Ships in 24 hours

Hager ADM420T 20A RCBO with 4 protected poles (3P+N), pairing C curve overload and short-circuit protection with 30mA Type A earth leakage detection. 6kA rated, 230-415V AC, 4 modules wide, IP2X. For residential and commercial distribution boards.

Electrotraders USPs

Fast Shipping, Trusted by Government, Easy Returns, Free Shipping over $200


Description

20A earth leakage and overcurrent protection, 4 poles.

Hager's ADM420T packs a 20A C curve circuit breaker and a 30mA Type A safety switch into one 4 module RCBO. Each three-phase circuit gets its own dedicated earth leakage protection, so a single fault trips only the affected circuit instead of a shared RCD group.

Key Features

  • Current rating: 20A, C tripping curve
  • Earth leakage sensitivity: 30mA, Type A
  • Pole configuration: 3P+N with all 4 poles protected
  • Short-circuit rating: 6kA Icn / 6kA Ics (IEC 60898-1)
  • Operating voltage: 230-415V AC, 50Hz
  • Footprint: 4 DIN modules, 71 x 84 x 70mm (W x H x D)
  • Neutral on the right-hand side
  • Screw top terminal, biconnect bottom terminal
  • I²t energy limitation class 3, IP2X

Grab yours now – dispatched within 24 hours to any Australian address.

 

What the ADM420T Brings to Your Switchboard

Breaker and safety switch combined
An RCBO merges the job of a miniature circuit breaker (MCB) with that of a residual current device (RCD). The ADM420T disconnects its circuit when current exceeds its 20A rating for too long, when a short-circuit occurs, or when leakage to earth reaches 30mA. Hager specifies it for 3-phase or single-phase systems within its 230-415V AC operating range.

Why Type A and curve C
A Type A residual current element detects both sinusoidal AC and pulsating DC earth fault currents. The C curve tolerates the brief inrush that occurs when mixed or moderately inductive loads switch on, helping reduce nuisance tripping. Energy limitation class 3 means the device restricts the let-through energy during a short-circuit.

Specifying and fitting notes

  • At 30°C the full 20A applies; this falls to 19.1A at 40°C and 17.2A at 60°C.
  • Multiply the rating by 0.80 where two devices sit side by side.
  • Cable range: 1-16mm² flexible, 1-25mm² solid, with terminals torqued to 2Nm.
  • Power dissipation is 11.7W at rated current, worth factoring into enclosure heat calculations.
  • Must be installed by a licensed electrician to AS/NZS 3000.

Q: Can the Hager ADM420T be used on a single-phase supply?
A: Hager states the ADM420T suits 3-phase or single-phase systems, with a rated operational voltage of 230-415V AC.

Q: How much current can the Hager ADM420T carry at 40°C?
A: Hager rates it at 19.1A at 40°C ambient, compared with its full 20A rating at 30°C.

Q: What cable sizes fit the Hager ADM420T terminals?
A: The screw terminals take flexible conductors from 1 to 16mm² and solid conductors from 1 to 25mm².

(hagrcb420)

Specifications

Electric current
Rated current20 A
Rated residual operating current Idn30 mA
Rated current -25DegC23,80 A
Rated current at -20DegC23,50 A
Rated current -15DegC23,20 A
Rated current -10DegC22,90 A
Rated current -5DegC22,50 A
Rated current at 0DegC22,20 A
Rated current 5DegC21,80 A
Rated current 10DegC21,50 A
Rated current 15DegC21,10 A
Rated current at 20DegC20,80 A
Rated current 25DegC20,40 A
Rated current 30DegC20 A
Rated current 35DegC19,60 A
Rated current at 40DegC19,10 A
Rated current at 45DegC18,60 A
Rated current at 50DegC18,20 A
Rated current 55DegC17,70 A
Rated current 60DegC17,20 A
Rated short-circuit breaking capacity Icn under 230 V AC according to IEC 61009-16 kA
Architecture
CurveC
Neutral positionRight
Type of pole4P
Number of protected poles4
Capacity
Number of modules4
Safety
Residual current typeA
Ingress Protection (IP) classIP2X
Voltage
Type voltage supplyAC
Rated operational voltage Ue230 - 415 V
Rated insulation voltage Ui500 V
Dielectric strength value of power frequency2 kV
Rated impulse withstand voltage Uimp4000 V
Overvoltage category according to IEC 60947-13
Installation, mounting
Nominal tightening torque top terminal2 - 2 Nm
Nominal tightening torque down terminal2 - 2 Nm
Nominal tightening torque2 - 2 Nm
360?ø mounting position possibleYes
Type of top connection for modular devicesScrew terminal
Type of bottom connection for modular devicesbiconnect, Bypass
Main electrical attributes
Rated short-circuit breaking capacity Icn AC according to IEC 60898-16 kA
Frequency
Frequency50 - 50 Hz
Connection
Cross-section of input with screws, for flexible conductors1 - 16 mm^2
Cross-section of input with screws, for massive conductors1 - 25 mm^2
Use conditions
Class of energy limitation I^2t3
Operating temperature-25 - 40 DegC
Dimensions
Height84 mm
Width71 mm
Depth70 mm
Power
Total power loss under IN11,70 W
SKU hagrcb420
Manfacturer Part Number ADM420T