Hager ADM416T RCBO Safety Switch 16A 4 Pole (3P+N) 6kA C Curve 30mA Type A 230-415V 4 Module DIN Rail
SKU: hagrcb416
Product Image Gallery
Product Pricing
$170.63 (ex-GST)
$187.69 (inc-GST)
$187.69
$170.63
Stock and Availability
- ⚫︎ Ships in 24 hours
Hager ADM416T 4 pole (3P+N) RCBO combining 16A C curve overcurrent and 30mA Type A earth leakage protection in one 4 module DIN rail device. 6kA breaking capacity, 230-415V AC, IP2X. Suits residential and light commercial three-phase switchboards.
Electrotraders USPs
Description
Three-phase circuit protection in one compact device.
The Hager ADM416T is a 16A, 4 pole (3P+N) RCBO that combines overload, short-circuit and 30mA earth leakage protection in a single 4 module DIN rail unit. It removes the need for a separate RCD and MCB on each three-phase final subcircuit, saving switchboard space and wiring time.
Key Features
- Rated current: 16A
- Poles: 4 pole (3P+N), 4 protected poles
- Tripping curve: C
- Residual current: 30mA, Type A
- Breaking capacity: 6kA (Icn and Ics to IEC 60898-1)
- Rated operational voltage: 230-415V AC, 50Hz
- Width: 4 modules (71mm), right-hand neutral
- Terminals: screw top, biconnect bottom, cables 1-25mm²
- Energy limitation class 3, IP2X, 360° mounting
Secure yours today – ships within 24 hours with fast delivery Australia-wide.
Why a 4 Pole RCBO Matters in Three-Phase Boards
One device, three protection functions
An RCBO (residual current breaker with overcurrent protection) is an MCB and an RCD built into one device. The ADM416T trips on sustained overload through its thermal element, on short-circuit through its magnetic element, and on earth leakage at 30mA. Because each three-phase circuit gets its own residual current protection, a fault on one circuit does not take down others sharing a common RCD.
Type A detection and C curve performance
Type A residual current detection responds to AC and pulsating DC earth fault currents. The C curve suits mixed and moderately inductive loads where short inrush currents occur at switch-on. With a 6kA rated breaking capacity and I²t energy limitation class 3, the ADM416T is built for Hager's stated application: residential and light commercial distribution boards.
Planning your installation
- Derating applies above 30°C: 16A at 30°C, 15.2A at 40°C and 13.6A at 60°C.
- Apply a 0.80 correction factor when two devices are mounted side by side.
- Terminals accept flexible conductors 1-16mm² and solid conductors 1-25mm², tightened to 2Nm.
- Installation must be carried out by a licensed electrician in accordance with AS/NZS 3000 Wiring Rules.
Q: What is the difference between the Hager ADM416T and a standard 4 pole MCB?
A: A standard MCB only protects against overload and short-circuit. The ADM416T adds 30mA Type A earth leakage protection, so it acts as both a circuit breaker and a safety switch in one 4 module device.
Q: How wide is the Hager ADM416T RCBO?
A: It occupies 4 DIN rail modules, measuring 71mm wide, 84mm high and 70mm deep, with the neutral pole on the right-hand side.
Q: Can accessories be added to the Hager ADM416T?
A: Yes. Hager lists optional accessories for this RCBO, including auxiliary and alarm contacts (MZ201, MZ202), shunt trips (MZ203, MZ204), an undervoltage release (MZ206), a padlockable locking kit (MZN175) and modular busbars.
(hagrcb416)
Specifications
| Electric current | |
| Rated current | 16 A |
| Rated residual operating current Idn | 30 mA |
| Rated current -25DegC | 19,40 A |
| Rated current at -20DegC | 19,10 A |
| Rated current -15DegC | 18,90 A |
| Rated current -10DegC | 18,60 A |
| Rated current -5DegC | 18,30 A |
| Rated current at 0DegC | 18 A |
| Rated current 5DegC | 17,60 A |
| Rated current 10DegC | 17,30 A |
| Rated current 15DegC | 17 A |
| Rated current at 20DegC | 16,70 A |
| Rated current 25DegC | 16,30 A |
| Rated current 30DegC | 16 A |
| Rated current 35DegC | 15,60 A |
| Rated current at 40DegC | 15,20 A |
| Rated current at 45DegC | 14,90 A |
| Rated current at 50DegC | 14,40 A |
| Rated current 55DegC | 14 A |
| Rated current 60DegC | 13,60 A |
| Rated short-circuit breaking capacity Icn under 230 V AC according to IEC 61009-1 | 6 kA |
| Architecture | |
| Curve | C |
| Neutral position | Right |
| Type of pole | 4P |
| Number of protected poles | 4 |
| Capacity | |
| Number of modules | 4 |
| Safety | |
| Residual current type | A |
| Ingress Protection (IP) class | IP2X |
| Voltage | |
| Type voltage supply | AC |
| Rated operational voltage Ue | 230 - 415 V |
| Rated insulation voltage Ui | 500 V |
| Dielectric strength value of power frequency | 2 kV |
| Rated impulse withstand voltage Uimp | 4000 V |
| Overvoltage category according to IEC 60947-1 | 3 |
| Installation, mounting | |
| Nominal tightening torque top terminal | 2 - 2 Nm |
| Nominal tightening torque down terminal | 2 - 2 Nm |
| Nominal tightening torque | 2 - 2 Nm |
| 360?ø mounting position possible | Yes |
| Type of top connection for modular devices | Screw terminal |
| Type of bottom connection for modular devices | biconnect, Bypass |
| Main electrical attributes | |
| Rated short-circuit breaking capacity Icn AC according to IEC 60898-1 | 6 kA |
| Frequency | |
| Frequency | 50 - 50 Hz |
| Connection | |
| Cross-section of input with screws, for flexible conductors | 1 - 16 mm^2 |
| Cross-section of input with screws, for massive conductors | 1 - 25 mm^2 |
| Use conditions | |
| Class of energy limitation I^2t | 3 |
| Operating temperature | -25 - 40 DegC |
| Dimensions | |
| Height | 84 mm |
| Width | 71 mm |
| Depth | 70 mm |
| Power | |
| Total power loss under IN | 10,90 W |
| SKU | hagrcb416 |
| Manfacturer Part Number | ADM416T |
| Barcode # | 3250611032946 |
| Brand | Hager |