Hager ADA916T 16 Amps 1 Pole plus Neutral RCBO Safety Switch 6kA 30mA Type A C Curve 2 Module DIN Rail

SKU: hagrcb2166k

Product Image Gallery

Product image thumbnail for SKU hagrcb2166k

Product Pricing

$39.31 (ex-GST)

$43.24 (inc-GST)

$43.24

$39.31

(inc-GST)
(ex-GST)

Stock and Availability

  • ⚫︎ Only 1 Left!

Hager ADA916T 1P+N RCBO in a 2 module (35 mm) DIN device. 16 A C curve, 30 mA Type A earth leakage sensing and 6 kA breaking capacity on 230-240 V. Screw terminals to 25 mm2 rigid, IP2X, IEC 60898-1. In stock, ships in 24 hours across Australia.

Electrotraders USPs

Fast Shipping, Trusted by Government, Easy Returns, Free Shipping over $200


Description

16 A 1P+N safety switch, two module.

The Hager ADA916T combines MCB and RCD protection for a 16 A final circuit, switching both active and neutral in a robust 2 module (35 mm) device. It delivers full 1P+N protection to single-phase power and lighting circuits with an inbuilt RCD test button.

Key Features

  • Hager ADA916T RCBO, 1 pole plus neutral, 2 module (35 mm) wide
  • 16 A rated current, C curve tripping characteristic
  • 30 mA rated residual operating current, Type A
  • 6 kA rated short circuit breaking capacity (Icn, IEC 60898-1)
  • 230 - 240 V AC rated operational voltage
  • Rated insulation voltage 500 V, impulse withstand 4 kV, energy limitation class 3
  • Built-in test button, screw terminals top and bottom
  • Accepts 1 - 25 mm² rigid or 1 - 16 mm² flexible conductors
  • Mounts on 35 mm DIN rail, IP2X rated
  • Bypass bottom connection for busbar wiring
  • Nominal tightening torque 2.10 Nm
  • Manufactured to IEC 60898-1, RoHS conform

Add to basket - in stock and dispatched Australia-wide within 24 hours.

 

Two-Module 1P+N Protection

The ADA916T switches and protects both the active and the neutral conductor in a full-size 2 module (35 mm) body, height 83 mm and depth 68 mm. The wider format gives generous terminal access and takes rigid conductors up to 25 mm². A built-in test button lets the installer verify the RCD function, and the unit resets easily once a fault is cleared.

16 A for General Final Circuits

The 16 A C curve rating suits general final subcircuits: power points, lighting and mixed loads on single-phase supplies. The C curve tolerates the ordinary inrush of everyday equipment while tripping promptly on a genuine overload or short circuit, all with 30 mA earth leakage protection built into the one device.

Type A Earth Leakage Sensing

As a Type A RCBO the ADA916T detects both sinusoidal AC earth leakage and pulsating DC earth leakage, unlike Type AC which detects only the AC component. With switch mode power supplies, inverters and variable speed drives now common on Australian final circuits, Type A is the practical baseline. It trips at a rated residual current of 30 mA.

Rated for Australian Conditions

Rated operational voltage is 230 - 240 V, matching the Australian supply. Hager publishes a full derating curve: 16 A at 30 °C ambient, 15.60 A at 40 °C and 14.80 A at 60 °C, and side-by-side correction factors when devices are grouped in a board (0.95 for three units, 0.90 for four to five). The operating range is -25 to 40 °C and the device is rated to 2000 m altitude.

Q: Is the Hager ADA916T single pole or double pole?
A: It is a 1 pole plus neutral (1P+N) device that switches and protects both the active and neutral conductors. It occupies 2 modules (35 mm) of DIN rail. The single-module equivalent is the Hager ADC916T.

Q: Does the ADA916T have a test button?
A: Yes. It has an inbuilt test switch to verify the residual current function, and resets easily once the fault is rectified. As a Type A device it trips at 30 mA residual current.

Q: What cable sizes do the ADA916T terminals take?
A: The screw terminals accept 1 - 25 mm² rigid or 1 - 16 mm² flexible conductors, tightened to 2.10 Nm.

(hagrcb2166k)

Specifications

Architecture
Type of pole1P+N
CurveC
Electric current
Rated current16 A
Rated residual operating current Idn30 mA
Rated current -25DegC18,50 A
Rated current at -20DegC18,30 A
Rated current -15DegC18,10 A
Rated current -10DegC17,90 A
Rated current -5DegC17,70 A
Rated current at 0DegC17,40 A
Rated current 5DegC17,20 A
Rated current 10DegC17 A
Rated current 15DegC16,70 A
Rated current at 20DegC16,50 A
Rated current 25DegC16,20 A
Rated current 30DegC16 A
Rated current 35DegC15,80 A
Rated current at 40DegC15,60 A
Rated current at 50DegC15,20 A
Rated current 55DegC15 A
Rated current 60DegC14,80 A
Correction factor of rating current for 2 devices placed side by side1
Correction factor of rating current for 3 devices placed side by side0,95
Correction factor of rating current for 4 and 5 devices placed side by side0,90
Correction factor of rating current for 6 devices placed side by side0,85
Min./max. threshold value of the AC thermal operation1,13 - 1,45 A
Safety
Residual current typeA
Ingress Protection (IP) classIP2X
Main electrical attributes
Rated short-circuit breaking capacity Icn AC according to IEC 60898-16 kA
Connectivity
Type of connectionScrew terminal
Voltage
Rated insulation voltage Ui500 V
Rated impulse withstand voltage Uimp4000 V
Max. operating voltage240 V
Rated operational voltage Ue230 - 240 V
Overvoltage category according to IEC 60947-13
Power
Total power loss under IN5,20 W
Frequency
Frequency50 - 50 Hz
Use conditions
Max. Altitude2000 m
Class of energy limitation I^2t3
Operating temperature-25 - 40 DegC
Storage/transport temperature-25 - 70 DegC
Endurance
Electric endurance in number of cycles2000
Number of mechanical operations2000
Connection
Cross-section flexible conductor1 - 16 mm^2
Cross-section rigid conductor1 - 25 mm^2
Cross-section of input with screws, for flexible conductors1 - 16 mm^2
Cross-section of input with screws, for massive conductors1 - 25 mm^2
Cross-section of output with screws, for flexible conductors1 - 16 mm^2
Cross-section of output with screws, for massive conductors1 - 25 mm^2
Cross-section of input and output with screws, for flexible conductors1 - 16 mm^2
Cross-section of input and output with screws, for massive conductors1 - 25 mm^2
Installation, mounting
Nominal tightening torque2,10 - 2,10 Nm
Type of top connection for modular devicesScrew terminal
Type of bottom connection for modular devicesbiconnect, Bypass
Capacity
Number of modules2
Dimensions
Height83 mm
Width35 mm
Depth68 mm
Compatibility
Suitable for DIN RailYes
SKU hagrcb2166k
Manfacturer Part Number ADA916T
Barcode # 3250611011606
Brand Hager