Hager MSN340 Miniature Circuit Breaker MCB 40A 3 Pole C Curve 6kA 3 Module DIN Rail 415V

SKU: hagmcb3406k

Product Image Gallery

Product image thumbnail for SKU hagmcb3406k

Product Pricing

$42.00 (ex-GST)

$46.20 (inc-GST)

$46.20

$42.00

(inc-GST)
(ex-GST)

Stock and Availability

  • ⚫︎ Only 1 Left!

Hager MSN340 40A three-pole miniature circuit breaker (MCB) with C tripping curve and 6kA breaking capacity. 3-module DIN rail design protects three-phase circuits against overload and short circuit. AS/NZS 60898 compliant.

Electrotraders USPs

Fast Shipping, Trusted by Government, Easy Returns, Free Shipping over $200


Description

Three-phase 40A protection.

The Hager MSN340 is a 40A three-pole miniature circuit breaker (MCB) with a C tripping curve and 6kA breaking capacity, protecting three-phase residential and light commercial circuits against overload and short circuit from a 3-module DIN rail body.

Key Features

  • Rated current: 40A, three-phase (3P)
  • C tripping curve (5–10x In)
  • 6kA breaking capacity (Icn) to IEC 60898-1
  • Rated voltage 415V AC, insulation voltage 500V
  • 3-module width (52.5mm) DIN rail mount
  • Accepts conductors 1–35mm² rigid, 1–25mm² flexible
  • Energy limiting class 3; IP20; 360° mounting
  • Compliant with AS/NZS 60898.1

Order online now – fast dispatch on Hager circuit protection Australia-wide.

 

Why it Matters

Protects all three phases together.
The MSN340 is a 40A three-pole miniature circuit breaker, protecting a three-phase circuit against both overload and short circuit and tripping automatically when either occurs. Its three linked poles switch and protect all three phases as one, suited to heavy three-phase sub-mains and distribution feeds in homes and light commercial boards – larger motors, plant and machinery – with a 6kA breaking capacity for the fault levels found in those switchboards.

C curve for motor and mixed loads.
The C tripping characteristic trips on short circuit at 5 to 10 times rated current, the general-purpose curve suited to mixed resistive and inductive loads including the inrush of three-phase motors. Backed by a 6kA short-circuit breaking capacity to IEC 60898-1 and energy limiting class 3, the MSN340 limits let-through energy during a fault to help protect downstream cabling.

Built for Australian switchboards.
At three modules (52.5mm) wide, 83mm high and 70mm deep, the MSN340 clips onto standard 35mm DIN rail with 360° mounting flexibility, and its terminals take rigid conductors up to 35mm² at 2.8Nm. It is compliant with AS/NZS 60898.1, rated IP20, and operates from -25°C to 70°C to suit distribution boards and homes across Australian conditions. With 16.88W dissipation per pole at full load, allow for heat in tightly packed boards. Hager auxiliaries including the MZ201 auxiliary contact, MZ202 alarm contact and MZ203/MZ204 shunt trips are available.

Q: Is the Hager MSN340 a three-phase breaker?
Yes. It is a 3-pole (3P) MCB that switches and protects all three phases of a 415V circuit together; it does not include a separate neutral pole.

Q: What does the C curve mean on the MSN340?
The C curve trips on short circuit at 5 to 10 times the rated current, making it the general-purpose characteristic for mixed resistive and inductive loads including motors.

Q: What is the difference between the MSN340 (6kA) and a 10kA MCB?
6kA is the rated short-circuit breaking capacity, suited to residential and light commercial boards; a 10kA breaker such as Hager's NT range is specified where fault levels are higher, typically in commercial and industrial installations.

(hagmcb3406k)

Specifications

Electric current
Rated current 40 A
Rated current -15DegC 48,4 A
Rated current -10DegC 47,5 A
Rated current -5DegC 46,6 A
Rated current at 0DegC 45,8 A
Rated current 5DegC 44,8 A
Rated current 10DegC 43,9 A
Rated current 15DegC 43 A
Rated current at 20DegC 42 A
Rated current 25DegC 41 A
Rated current 30DegC 40 A
Rated current 35DegC 38,8 A
Rated current at 40DegC 37,5 A
Rated current at 45DegC 36,2 A
Rated current at 50DegC 34,8 A
Rated current 55DegC 33,4 A
Rated current 60DegC 31,9 A
Rated current 65DegC 30,3 A
Rated current 70DegC 28,6 A
Architecture
Type of pole 3P
Curve C
Capacity
Number of modules 3
Installation, mounting
Nominal tightening torque top terminal 2,80 - 2,80 Nm
Nominal tightening torque down terminal 2,80 - 2,80 Nm
Nominal tightening torque 2,80 - 2,80 Nm
Type of bottom connection for modular devices biconnect
Type of top connection for modular devices Screw terminal
360?ø mounting position possible Yes
Main electrical attributes
Rated short-circuit breaking capacity Icn AC according to IEC 60898-1 6 kA
Voltage
Rated operational voltage Ue 415 - 415 V
Type voltage supply AC
Rated insulation voltage Ui 500 V
Rated impulse withstand voltage Uimp 4000 V
Frequency
Frequency 50 - 60 Hz
Connection
Cross-section of input and output with screws, for massive conductors 1 - 35 mm^2
Cross-section of input and output with screws, for flexible conductors 1 - 25 mm^2
Cross-section of input with screws, for flexible conductors 1 - 25 mm^2
Cross-section of input with screws, for massive conductors 1 - 35 mm^2
Cross-section flexible conductor 1 - 25 mm^2
Cross-section rigid conductor 1 - 35 mm^2
Safety
Ingress Protection (IP) class IP20
Use conditions
Degree of pollution according to IEC 60664 / IEC 60947-2 2
Class of energy limitation I^2t 3
Air humidity protection For all climates
Operating temperature -25 - 70 DegC
Power
Total power loss under IN 16,88 W
Connectivity
Type of connection Screw terminal
Top connection alignment for modular devices Aligned terminal
Down connection alignment for modular devices Aligned terminal
Dimensions
Height 83 mm
Width 52,50 mm
Depth 70 mm
SKU hagmcb3406k
Manfacturer Part Number MSN340
Barcode # 3250614323621
Brand Hager

Shipping Calculator