Hager MSN350 Miniature Circuit Breaker MCB 50A 3 Pole C Curve 6kA 3 Module DIN Rail 415V
SKU: hagmcb3506k
Product Image Gallery
Product Pricing
$42.00 (ex-GST)
$46.20 (inc-GST)
$46.20
$42.00
Stock and Availability
- ⚫︎ Only 1 Left!
Hager MSN350 50A three-pole miniature circuit breaker (MCB) with C tripping curve and 6kA breaking capacity. 3-module DIN rail design protects three-phase circuits against overload and short circuit. AS/NZS 60898 compliant.
Electrotraders USPs
Description
Three-phase 50A protection.
The Hager MSN350 is a 50A three-pole miniature circuit breaker (MCB) with a C tripping curve and 6kA breaking capacity, protecting three-phase residential and light commercial circuits against overload and short circuit from a 3-module DIN rail body.
Key Features
- Rated current: 50A, three-phase (3P)
- C tripping curve (5–10x In)
- 6kA breaking capacity (Icn) to IEC 60898-1
- Rated voltage 415V AC, insulation voltage 500V
- 3-module width (52.5mm) DIN rail mount
- Accepts conductors 1–35mm² rigid, 1–25mm² flexible
- Energy limiting class 3; IP20; 360° mounting
- Compliant with AS/NZS 60898.1
Order online now – fast dispatch on Hager circuit protection Australia-wide.
Why it Matters
Protects all three phases together.
The MSN350 is a 50A three-pole miniature circuit breaker, protecting a three-phase circuit against both overload and short circuit and tripping automatically when either occurs. Its three linked poles switch and protect all three phases as one, suited to heavy three-phase sub-mains and distribution feeds in homes and light commercial boards – large motors, plant and machinery – with a 6kA breaking capacity for the fault levels found in those switchboards.
C curve for motor and mixed loads.
The C tripping characteristic trips on short circuit at 5 to 10 times rated current, the general-purpose curve suited to mixed resistive and inductive loads including the inrush of three-phase motors. Backed by a 6kA short-circuit breaking capacity to IEC 60898-1 and energy limiting class 3, the MSN350 limits let-through energy during a fault to help protect downstream cabling.
Built for Australian switchboards.
At three modules (52.5mm) wide, 83mm high and 70mm deep, the MSN350 clips onto standard 35mm DIN rail with 360° mounting flexibility, and its terminals take rigid conductors up to 35mm² at 2.8Nm. It is compliant with AS/NZS 60898.1, rated IP20, and operates from -25°C to 70°C to suit distribution boards and homes across Australian conditions. With 16.3W dissipation per pole at full load, allow for heat in tightly packed boards. Hager auxiliaries including the MZ201 auxiliary contact, MZ202 alarm contact and MZ203/MZ204 shunt trips are available.
Q: Is the Hager MSN350 a three-phase breaker?
Yes. It is a 3-pole (3P) MCB that switches and protects all three phases of a 415V circuit together; it does not include a separate neutral pole.
Q: What does the C curve mean on the MSN350?
The C curve trips on short circuit at 5 to 10 times the rated current, making it the general-purpose characteristic for mixed resistive and inductive loads including motors.
Q: What is the difference between the MSN350 (6kA) and a 10kA MCB?
6kA is the rated short-circuit breaking capacity, suited to residential and light commercial boards; a 10kA breaker such as Hager's NT range is specified where fault levels are higher, typically in commercial and industrial installations.
(hagmcb3506k)
Specifications
| Electric current | |
| Rated current | 50 A |
| Rated current -15DegC | 61,4 A |
| Rated current -10DegC | 60,2 A |
| Rated current -5DegC | 59,1 A |
| Rated current at 0DegC | 57,9 A |
| Rated current 5DegC | 56,6 A |
| Rated current 10DegC | 55,4 A |
| Rated current 15DegC | 54,1 A |
| Rated current at 20DegC | 52,8 A |
| Rated current 25DegC | 51,4 A |
| Rated current 30DegC | 50 A |
| Rated current 35DegC | 48,5 A |
| Rated current at 40DegC | 47 A |
| Rated current at 45DegC | 45,4 A |
| Rated current at 50DegC | 43,7 A |
| Rated current 55DegC | 42 A |
| Rated current 60DegC | 40,2 A |
| Rated current 65DegC | 38,3 A |
| Rated current 70DegC | 36,3 A |
| Architecture | |
| Type of pole | 3P |
| Curve | C |
| Capacity | |
| Number of modules | 3 |
| Installation, mounting | |
| Nominal tightening torque top terminal | 2,80 - 2,80 Nm |
| Nominal tightening torque down terminal | 2,80 - 2,80 Nm |
| Nominal tightening torque | 2,80 - 2,80 Nm |
| Type of bottom connection for modular devices | biconnect |
| Type of top connection for modular devices | Screw terminal |
| 360?ø mounting position possible | Yes |
| Main electrical attributes | |
| Rated short-circuit breaking capacity Icn AC according to IEC 60898-1 | 6 kA |
| Voltage | |
| Rated operational voltage Ue | 415 - 415 V |
| Type voltage supply | AC |
| Rated insulation voltage Ui | 500 V |
| Rated impulse withstand voltage Uimp | 4000 V |
| Frequency | |
| Frequency | 50 - 60 Hz |
| Connection | |
| Cross-section of input and output with screws, for massive conductors | 1 - 35 mm^2 |
| Cross-section of input and output with screws, for flexible conductors | 1 - 25 mm^2 |
| Cross-section of input with screws, for flexible conductors | 1 - 25 mm^2 |
| Cross-section of input with screws, for massive conductors | 1 - 35 mm^2 |
| Cross-section flexible conductor | 1 - 25 mm^2 |
| Cross-section rigid conductor | 1 - 35 mm^2 |
| Safety | |
| Ingress Protection (IP) class | IP20 |
| Use conditions | |
| Degree of pollution according to IEC 60664 / IEC 60947-2 | 2 |
| Class of energy limitation I^2t | 3 |
| Air humidity protection | For all climates |
| Operating temperature | -25 - 70 DegC |
| Power | |
| Total power loss under IN | 16,30 W |
| Connectivity | |
| Type of connection | Screw terminal |
| Top connection alignment for modular devices | Aligned terminal |
| Down connection alignment for modular devices | Aligned terminal |
| Dimensions | |
| Height | 83 mm |
| Width | 52,50 mm |
| Depth | 70 mm |
| SKU | hagmcb3506k |
| Manfacturer Part Number | MSN350 |
| Barcode # | 3250613810177 |
| Brand | Hager |