Hager ADM440T 40A 4 Pole (3P+N) RCBO 6kA C Curve 30mA Type A Safety Switch 230-415V AC 4 Module DIN Rail
SKU: hagrcb440
Product Image Gallery
Product Pricing
$170.63 (ex-GST)
$187.69 (inc-GST)
$187.69
$170.63
Stock and Availability
- ⚫︎ Ships in 24 hours
Hager ADM440T is a 40A 4 pole RCBO joining overcurrent and residual current protection in one 4 module unit. C curve tripping, 30mA Type A shock protection, 6kA breaking capacity, 230-415V AC, IP2X, screw and biconnect terminals, DIN rail mount.
Electrotraders USPs
Description
The 40A top of the Hager ADM three-phase range.
The ADM440T carries the highest current rating in Hager's 4 pole ADM RCBO series. It brings overcurrent and residual current protection together for three-phase circuits, sized for heavier final subcircuits that still need 30mA earth leakage protection at the device itself.
Key Features
- Current rating: 40A with C curve tripping
- Earth leakage: 30mA, Type A residual sensing
- Pole arrangement: 3P+N, all four poles protected
- Fault capacity: 6kA Icn and 6kA Ics to IEC 60898-1
- Voltage range: 230-415V AC at 50Hz
- Module width: 4 (71mm), 84mm high, 70mm deep
- Screw and biconnect terminals with 360° mounting
- IP2X enclosure rating, I²t class 3
- Endurance: 2,000 electrical cycles, 4,000 mechanical operations
Order now – leaves our warehouse within 24 hours for delivery Australia-wide.
Choosing the 40A ADM440T
Protection roles in one unit
Hager describes this device as combining overcurrent and residual current protection for three-phase circuits. In practice that means one 4 module unit does the work of a 40A four pole breaker plus a 30mA safety switch. Hager rates the Type A residual element for enhanced shock protection and positions the device for residential and light commercial loads.
Headroom and heat at 40A
Higher-rated devices run warmer. The ADM440T dissipates 17.7W at its rated current, so allow for that heat when populating a full board. Ambient temperature also matters: the 40A rating holds at 30°C, easing to 37.7A at 40°C and 32.6A at 60°C. Two devices mounted side by side attract a 0.80 correction factor.
Wiring and mounting
- Terminals take 1-16mm² flexible or 1-25mm² solid conductors at 2Nm torque.
- Screw connection at the top, biconnect or bypass at the bottom, with 360° mounting positions.
- Insulation voltage 500V, impulse withstand 4kV, overvoltage category 3.
- Rated for use from -25 to 40°C and up to 2000m altitude, pollution degree 2.
- Install through a licensed electrician in accordance with AS/NZS 3000.
Q: What size circuit does the Hager ADM440T suit?
A: It is rated 40A with a C curve, making it the highest rated device in Hager's 4 pole ADM RCBO range, intended for three-phase circuits at 230-415V AC.
Q: Does the Hager ADM440T protect the neutral as well?
A: Its configuration is 3P+N with four protected poles, so the neutral is switched and protected along with the three phases.
Q: How much heat does the Hager ADM440T generate?
A: Hager lists power dissipation of 17.7W at rated current, higher than the lower-rated devices in the same range.
(hagrcb440)
Specifications
| Electric current | |
| Rated current | 40 A |
| Rated residual operating current Idn | 30 mA |
| Rated current -25DegC | 49,80 A |
| Rated current at -20DegC | 49 A |
| Rated current -15DegC | 48,20 A |
| Rated current -10DegC | 47,30 A |
| Rated current -5DegC | 46,50 A |
| Rated current at 0DegC | 45,60 A |
| Rated current 5DegC | 44,70 A |
| Rated current 10DegC | 43,80 A |
| Rated current 15DegC | 42,90 A |
| Rated current at 20DegC | 42 A |
| Rated current 25DegC | 41 A |
| Rated current 30DegC | 40 A |
| Rated current 35DegC | 38,90 A |
| Rated current at 40DegC | 37,70 A |
| Rated current at 45DegC | 36,50 A |
| Rated current at 50DegC | 35,20 A |
| Rated current 55DegC | 33,90 A |
| Rated current 60DegC | 32,60 A |
| Rated short-circuit breaking capacity Icn under 230 V AC according to IEC 61009-1 | 6 kA |
| Architecture | |
| Curve | C |
| Neutral position | Right |
| Type of pole | 4P |
| Number of protected poles | 4 |
| Capacity | |
| Number of modules | 4 |
| Safety | |
| Residual current type | A |
| Ingress Protection (IP) class | IP2X |
| Voltage | |
| Type voltage supply | AC |
| Rated operational voltage Ue | 230 - 415 V |
| Rated insulation voltage Ui | 500 V |
| Dielectric strength value of power frequency | 2 kV |
| Rated impulse withstand voltage Uimp | 4000 V |
| Overvoltage category according to IEC 60947-1 | 3 |
| Installation, mounting | |
| Nominal tightening torque top terminal | 2 - 2 Nm |
| Nominal tightening torque down terminal | 2 - 2 Nm |
| Nominal tightening torque | 2 - 2 Nm |
| 360?ø mounting position possible | Yes |
| Type of top connection for modular devices | Screw terminal |
| Type of bottom connection for modular devices | biconnect, Bypass |
| Main electrical attributes | |
| Rated short-circuit breaking capacity Icn AC according to IEC 60898-1 | 6 kA |
| Frequency | |
| Frequency | 50 - 50 Hz |
| Connection | |
| Cross-section of input with screws, for flexible conductors | 1 - 16 mm^2 |
| Cross-section of input with screws, for massive conductors | 1 - 25 mm^2 |
| Use conditions | |
| Class of energy limitation I^2t | 3 |
| Operating temperature | -25 - 40 DegC |
| Dimensions | |
| Height | 84 mm |
| Width | 71 mm |
| Depth | 70 mm |
| Power | |
| Total power loss under IN | 17,70 W |
| SKU | hagrcb440 |
| Manfacturer Part Number | ADM440T |
| Barcode # | 3250611032984 |
| Brand | Hager |