Hager ADD920T 20 Amps 1 Pole plus Neutral D Curve RCBO Safety Switch 6kA 30mA Type A 1 Module DIN Rail
SKU: hagrcb1206kd
Product Image Gallery
Product Pricing
$131.25 (ex-GST)
$144.38 (inc-GST)
$144.38
$131.25
Stock and Availability
- ⚫︎ Ships in 24 hours
Hager ADD920T 1P+N RCBO in a 17.7 mm DIN module. 20 A D curve for high-inrush loads, 30 mA Type A earth leakage sensing and 6 kA breaking capacity on 230-240 V. Screw and BIconnect terminals, IP20, IEC 60898-1. Ships in 24 hours across Australia.
Electrotraders USPs
Description
D curve safety switching in one module.
The Hager ADD920T packs combined MCB and RCD protection into a single 17.7 mm module. Its D curve rides out the high inrush from motors and transformers that trips a standard C curve device on start-up, while still cutting the supply on an earth fault.
Key Features
- Hager ADD920T RCBO, 1 pole plus neutral, 1 module (17.7 mm) wide
- 20 A rated current, D curve tripping characteristic
- 30 mA rated residual operating current, Type A
- 6 kA rated short circuit breaking capacity (Icn, IEC 60898-1)
- 230 - 240 V AC rated operational voltage, 50 - 60 Hz
- Rated insulation voltage 440 V, impulse withstand 4 kV, energy limitation class 3
- Screw terminal top, BIconnect bottom connection
- Accepts 1 - 16 mm² solid or 1 - 10 mm² flexible conductors
- Mounts on 35 mm DIN rail, IP20 rated
- Wide operating range: -25 to 70 °C
- 20,000 mechanical operations, 10,000 electrical cycles
- Manufactured to IEC 60898-1, RoHS conform
Order today - in stock and dispatched Australia-wide within 24 hours.
Why the D Curve Matters
A D curve breaker tolerates inrush currents of roughly 10 to 20 times its rated current before magnetic tripping, against 5 to 10 times for a C curve. That headroom keeps the circuit live through the brief current spike when motors, transformers, welders and large switch-mode supplies energise. Choose the ADD920T where a C curve RCBO nuisance-trips on start-up but you still need 30 mA earth leakage protection on the final circuit.
Full Protection, Single Module
This device protects both phase and neutral yet occupies just one 17.7 mm module of DIN rail. Height is 85 mm and depth 70 mm, so it fits standard flush and surface switchboards. The screw top terminal and BIconnect bottom terminal align it with the rest of a Hager modular assembly for tidy, fast fit-off.
Type A Earth Leakage Sensing
Type A residual current devices detect both sinusoidal AC earth leakage and pulsating DC earth leakage, unlike Type AC which detects only the AC component. With electronic loads such as EV chargers, inverters and variable speed drives now common on Australian final circuits, Type A is the practical baseline. The ADD920T trips at a rated residual current of 30 mA.
Rated for Australian Conditions
Rated operational voltage is 230 - 240 V at 50 - 60 Hz, matching the Australian supply, with a maximum operating voltage of 264 V. Hager publishes a full derating curve: 20 A at 30 °C ambient, 19.20 A at 40 °C and 17.60 A at 60 °C - useful where meter boxes and plant rooms run hot. The device is rated to 2000 m altitude.
Q: What is the difference between the ADD920T D curve and the ADC920T C curve?
A: Both are 20A 1P+N 6kA 30mA Type A RCBOs. The ADD920T has a D curve for high-inrush loads like motors and transformers, while the ADC920T has a C curve for general circuits. The D curve resists nuisance tripping on start-up surges.
Q: Is the Hager ADD920T single pole or double pole?
A: It is a 1 pole plus neutral (1P+N) device that switches and protects both the active and neutral conductors, in a single 17.7 mm module.
Q: Does the ADD920T detect DC earth leakage?
A: Yes. As a Type A RCBO it detects both sinusoidal AC and pulsating DC residual currents, tripping at 30 mA. It does not detect smooth DC leakage, which requires a Type B device.
(hagrcb1206kd)
Specifications
| Architecture | |
| Type of pole | 1P+N |
| Curve | D |
| Electric current | |
| Rated current | 20 A |
| Rated residual operating current Idn | 30 mA |
| Rated current -25DegC | 25,50 A |
| Rated current at -20DegC | 25 A |
| Rated current -15DegC | 24,50 A |
| Rated current -10DegC | 24 A |
| Rated current -5DegC | 23,50 A |
| Rated current at 0DegC | 23 A |
| Rated current 5DegC | 22,50 A |
| Rated current 10DegC | 22 A |
| Rated current 15DegC | 21,50 A |
| Rated current at 20DegC | 21 A |
| Rated current 25DegC | 20,50 A |
| Rated current 30DegC | 20 A |
| Rated current 35DegC | 19,60 A |
| Rated current at 40DegC | 19,20 A |
| Rated current at 50DegC | 18,40 A |
| Rated current 55DegC | 18 A |
| Rated current 60DegC | 17,60 A |
| Min./max. threshold value of the AC thermal operation | 1,13 - 1,45 A |
| Safety | |
| Residual current type | A |
| Ingress Protection (IP) class | IP20 |
| Main electrical attributes | |
| Rated short-circuit breaking capacity Icn AC according to IEC 60898-1 | 6 kA |
| Voltage | |
| Rated insulation voltage Ui | 440 V |
| Rated impulse withstand voltage Uimp | 4000 V |
| Max. operating voltage | 264 V |
| Rated operational voltage Ue | 230 - 240 V |
| Overvoltage category according to IEC 60947-1 | 3 |
| Power | |
| Total power loss under IN | 11,68 W |
| Frequency | |
| Frequency | 50 - 50 Hz |
| Use conditions | |
| Max. Altitude | 2000 m |
| Class of energy limitation I^2t | 3 |
| Operating temperature | -25 - 70 DegC |
| Storage/transport temperature | -25 - 80 DegC |
| Endurance | |
| Electric endurance in number of cycles | 10000 |
| Number of mechanical operations | 20000 |
| Connection | |
| Cross-section of input with screws, for flexible conductors | 1 - 10 mm^2 |
| Cross-section of input with screws, for massive conductors | 1 - 16 mm^2 |
| Cross-section of input and output with screws, for flexible conductors | 1 - 10 mm^2 |
| Cross-section of input and output with screws, for massive conductors | 1 - 16 mm^2 |
| Installation, mounting | |
| Type of top connection for modular devices | Screw terminal |
| Type of bottom connection for modular devices | biconnect |
| Capacity | |
| Number of modules | 1 |
| Dimensions | |
| Height | 85 mm |
| Width | 17,70 mm |
| Depth | 70 mm |
| Compatibility | |
| Suitable for DIN Rail | Yes |
| SKU | hagrcb1206kd |
| Manfacturer Part Number | ADD920T |
| Barcode # | 3250611033431 |
| Brand | Hager |