Hager ADD916T RCBO Safety Switch 16A 1P+N D Curve 6kA 30mA Type A 1 Module DIN Rail 230V
SKU: hagrcb1166kd
Product Image Gallery
Product Pricing
$131.25 (ex-GST)
$144.38 (inc-GST)
$144.38
$131.25
Stock and Availability
- ⚫︎ Ships in 24 hours
Hager ADD916T 16A single-pole-plus-neutral (1P+N) RCBO safety switch combining MCB and RCD protection: D-curve overcurrent, 6kA breaking, 30mA Type A earth leakage. Compact 1-module DIN rail device. AS/NZS 61009 compliant.
Electrotraders USPs
Description
Active and neutral protection for high-inrush circuits.
The Hager ADD916T is a 16A single-pole-plus-neutral (1P+N) RCBO combining D-curve overload and short-circuit protection with 30mA Type A earth-leakage protection, switching both active and neutral, for high-inrush circuits in a 1-module DIN rail device.
Key Features
- Rated current: 16A, single pole plus neutral (1P+N)
- D tripping curve (10–20x In) for high-inrush loads
- 6kA breaking capacity (Icn) to IEC 60898-1
- 30mA residual current, Type A (detects AC and pulsating DC)
- Rated voltage 230–240V AC (max 264V); insulation voltage 440V
- Compact 1-module width (17.7mm) DIN rail mount
- Accepts conductors 1–16mm² rigid, 1–10mm² flexible
- IP20; 20,000 mechanical / 10,000 electrical operations
Get yours today – fast dispatch on Hager safety switches Australia-wide.
Why it Matters
Switches active and neutral, tuned for inrush.
The ADD916T is a 1P+N RCBO – a residual current breaker with overcurrent protection that switches both the active and neutral conductors. It combines the functions of an MCB and an RCD in one module: protecting against overload and short circuit, and disconnecting on a 30mA earth-leakage fault to guard against electric shock. Breaking the neutral as well as the active fully isolates the final circuit for safe working.
D curve and Type A leakage detection.
The D tripping characteristic trips on short circuit at 10 to 20 times rated current, suited to circuits with high inrush – transformers, motors and switch-mode supplies – that would nuisance-trip a standard C-curve device. Its Type A residual sensing detects both AC and pulsating DC earth-leakage currents, covering modern electronic loads, and its 6kA breaking capacity suits the fault levels found in residential and light commercial switchboards.
Built for Australian switchboards.
At one module (17.7mm) wide, 85mm high and 70mm deep, the ADD916T clips onto standard 35mm DIN rail. Terminals take conductors up to 16mm², it is rated IP20 with a 4kV impulse withstand, and it operates from -25°C to 70°C with 20,000 mechanical and 10,000 electrical operations of endurance. It complies with AS/NZS 61009 for RCBOs and suits high-inrush final circuits requiring combined overcurrent and earth-leakage protection.
Q: What does 1P+N mean on the Hager ADD916T?
1P+N means the device protects and switches one active pole plus the neutral, breaking both conductors together to fully isolate the circuit – while still occupying just one DIN module.
Q: What does the D curve mean on the ADD916T?
The D curve trips on short circuit at 10 to 20 times the rated current, suited to high-inrush loads such as transformers and motors that would nuisance-trip a lower B or C curve.
Q: What is the difference between the ADD916T and the C-curve ADC916T?
Both are 16A 1P+N 6kA RCBOs; the ADD916T has a D curve for high-inrush loads, while the ADC916T has a C curve for general-purpose circuits.
(hagrcb1166kd)
Specifications
| Architecture | |
| Type of pole | 1P+N |
| Curve | D |
| Electric current | |
| Rated current | 16 A |
| Rated residual operating current Idn | 30 mA |
| Rated current -25DegC | 20,50 A |
| Rated current at -20DegC | 20,10 A |
| Rated current -15DegC | 19,70 A |
| Rated current -10DegC | 19,30 A |
| Rated current -5DegC | 18,90 A |
| Rated current at 0DegC | 18,50 A |
| Rated current 5DegC | 18,10 A |
| Rated current 10DegC | 17,60 A |
| Rated current 15DegC | 17,20 A |
| Rated current at 20DegC | 16,80 A |
| Rated current 25DegC | 16,40 A |
| Rated current 30DegC | 16 A |
| Rated current 35DegC | 15,70 A |
| Rated current at 40DegC | 15,50 A |
| Rated current at 50DegC | 15 A |
| Rated current 55DegC | 14,70 A |
| Rated current 60DegC | 14,50 A |
| Min./max. threshold value of the AC thermal operation | 1,13 - 1,45 A |
| Safety | |
| Residual current type | A |
| Ingress Protection (IP) class | IP20 |
| Main electrical attributes | |
| Rated short-circuit breaking capacity Icn AC according to IEC 60898-1 | 6 kA |
| Voltage | |
| Rated insulation voltage Ui | 440 V |
| Rated impulse withstand voltage Uimp | 4000 V |
| Max. operating voltage | 264 V |
| Rated operational voltage Ue | 230 - 240 V |
| Overvoltage category according to IEC 60947-1 | 3 |
| Power | |
| Total power loss under IN | 8,69 W |
| Frequency | |
| Frequency | 50 - 50 Hz |
| Use conditions | |
| Max. Altitude | 2000 m |
| Class of energy limitation I^2t | 3 |
| Operating temperature | -25 - 70 DegC |
| Storage/transport temperature | -25 - 80 DegC |
| Endurance | |
| Electric endurance in number of cycles | 10000 |
| Number of mechanical operations | 20000 |
| Connection | |
| Cross-section of input with screws, for flexible conductors | 1 - 10 mm^2 |
| Cross-section of input with screws, for massive conductors | 1 - 16 mm^2 |
| Cross-section of input and output with screws, for flexible conductors | 1 - 10 mm^2 |
| Cross-section of input and output with screws, for massive conductors | 1 - 16 mm^2 |
| Installation, mounting | |
| Type of top connection for modular devices | Screw terminal |
| Type of bottom connection for modular devices | biconnect |
| Capacity | |
| Number of modules | 1 |
| Dimensions | |
| Height | 85 mm |
| Width | 17,70 mm |
| Depth | 70 mm |
| Compatibility | |
| Suitable for DIN Rail | Yes |
| SKU | hagrcb1166kd |
| Manfacturer Part Number | ADD916T |
| Barcode # | 3250611033424 |
| Brand | Hager |