Hager ADC216T RCBO Safety Switch 16A 1 Pole C Curve 6kA 30mA Type A 1 Module DIN Rail 230V

SKU: hagrcb1166k1p

Product Image Gallery

Product image thumbnail for SKU hagrcb1166k1p
Product image thumbnail for SKU hagrcb1166k1p
Product image thumbnail for SKU hagrcb1166k1p
Product image thumbnail for SKU hagrcb1166k1p
Product image thumbnail for SKU hagrcb1166k1p
Product image thumbnail for SKU hagrcb1166k1p
Product image thumbnail for SKU hagrcb1166k1p

Product Pricing

$59.94 (ex-GST)

$65.93 (inc-GST)

$65.93

$59.94

(inc-GST)
(ex-GST)

Stock and Availability

  • ⚫︎ Ships in 24 hours

Hager ADC216T 16A single-pole RCBO safety switch combining MCB and RCD protection: C-curve overcurrent, 6kA breaking, 30mA Type A earth leakage. Compact 1-module DIN rail device. AS/NZS 61009 compliant.

Electrotraders USPs

Fast Shipping, Trusted by Government, Easy Returns, Free Shipping over $200


Description

Overcurrent and earth-leakage protection in one module.

The Hager ADC216T is a 16A single-pole RCBO (residual current breaker with overcurrent protection) combining C-curve overload and short-circuit protection with 30mA Type A earth-leakage protection in a compact 1-module DIN rail device.

Key Features

  • Rated current: 16A, single pole (1P)
  • C tripping curve (5–10x In)
  • 6kA breaking capacity (Icn) to IEC 60898-1
  • 30mA residual current, Type A (detects AC and pulsating DC)
  • Rated voltage 230–240V AC; insulation voltage 250V
  • Compact 1-module width (17.8mm) DIN rail mount
  • Accepts conductors 1–25mm² rigid, 1–16mm² flexible
  • IP20; rated impulse withstand 4000V; energy limiting class 3

Shop now – fast dispatch on Hager safety switches Australia-wide.

 

Why it Matters

Two protections in a single device.
The ADC216T is an RCBO – a residual current breaker with overcurrent protection – combining the functions of an MCB and an RCD in one module. It protects a circuit against overload and short circuit and, at the same time, disconnects on an earth-leakage fault of 30mA or more, guarding against electric shock. Combining both roles in one 1-module device saves board space compared with separate MCB and RCD components.

C curve and Type A leakage detection.
The C tripping characteristic trips on short circuit at 5 to 10 times rated current, the general-purpose curve suited to the mixed resistive and moderately inductive loads on most power-point and appliance circuits – where a 16A rating is one of the most common sizes. Its Type A residual sensing detects both AC and pulsating DC earth-leakage currents, covering modern electronic loads, and its 6kA breaking capacity suits the fault levels found in residential and light commercial switchboards.

Built for Australian switchboards.
At one module (17.8mm) wide, 115mm high and 70mm deep, the ADC216T clips onto standard 35mm DIN rail. Terminals take rigid conductors up to 25mm², and it is rated IP20 with a 4kV impulse withstand and energy limiting class 3. It complies with AS/NZS 61009 for RCBOs and suits final circuits – power points, appliance and equipment feeds – requiring combined overcurrent and earth-leakage protection.

Q: What is an RCBO and how is the ADC216T different from an MCB?
An RCBO combines an MCB and an RCD in one device: it protects against overload and short circuit like an MCB, and also trips on earth leakage (30mA here) to guard against electric shock – protection a plain MCB does not provide.

Q: What is the difference between the ADC216T (6kA) and a 10kA RCBO?
6kA is the rated short-circuit breaking capacity, suited to residential and light commercial boards; a 10kA RCBO such as the Hager ADC216B is specified where fault levels are higher.

Q: What does Type A mean on the ADC216T?
Type A residual current detection responds to both AC and pulsating DC earth-leakage currents, covering electronic loads that a basic Type AC device may not detect.

(hagrcb1166k1p)

Specifications

Architecture
Type of pole 1P
Curve C
Electric current
Rated current 16 A
Rated residual operating current Idn 30 mA
Rated current -25DegC 20,81 A
Rated current at -20DegC 20,38 A
Rated current -15DegC 19,94 A
Rated current -10DegC 19,50 A
Rated current -5DegC 19,06 A
Rated current at 0DegC 18,63 A
Rated current 5DegC 18,19 A
Rated current 10DegC 17,75 A
Rated current 15DegC 17,31 A
Rated current at 20DegC 16,88 A
Rated current 25DegC 16,44 A
Rated current 30DegC 16 A
Rated current 35DegC 15,70 A
Rated current at 40DegC 15,40 A
Rated current at 50DegC 14,80 A
Rated current 55DegC 14,50 A
Rated current 60DegC 14,20 A
Min./max. threshold value of the AC thermal operation 1,13 - 1,45 A
Safety
Residual current type A
Ingress Protection (IP) class IP20
Main electrical attributes
Rated short-circuit breaking capacity Icn AC according to IEC 60898-1 6 kA
Voltage
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 4000 V
Rated operational voltage Ue 230 - 240 V
Overvoltage category according to IEC 60947-1 3
Power
Total power loss under IN 4,90 W
Frequency
Frequency 50 - 60 Hz
Use conditions
Max. Altitude 2000 m
Class of energy limitation I^2t 3
Operating temperature -5 - 40 DegC
Storage/transport temperature -40 - 70 DegC
Endurance
Electric endurance in number of cycles 2000
Number of mechanical operations 10000
Connection
Cross-section of input with screws, for flexible conductors 1 - 10 mm^2
Cross-section of input with screws, for massive conductors 1 - 16 mm^2
Cross-section of input and output with screws, for flexible conductors 1 - 16 mm^2
Cross-section of input and output with screws, for massive conductors 1 - 25 mm^2
Installation, mounting
Type of top connection for modular devices Screw terminal
Type of bottom connection for modular devices biconnect
Capacity
Number of modules 1
Dimensions
Height 115 mm
Width 17,80 mm
Depth 70 mm
Compatibility
Suitable for DIN Rail Yes
SKU hagrcb1166k1p
Manfacturer Part Number ADC216T
Barcode # 3250611035534
Brand Hager