Hager ADA932T 32 Amps 1 Pole plus Neutral RCBO Safety Switch 6kA 30mA Type A C Curve 2 Module DIN Rail

SKU: hagrcb2326k

Product Image Gallery

Product image thumbnail for SKU hagrcb2326k
Product image thumbnail for SKU hagrcb2326k
Product image thumbnail for SKU hagrcb2326k
Product image thumbnail for SKU hagrcb2326k

Product Pricing

$42.94 (ex-GST)

$47.23 (inc-GST)

$47.23

$42.94

(inc-GST)
(ex-GST)

Stock and Availability

  • ⚫︎ Ships in 24 hours

Hager ADA932T 1P+N RCBO in a 2 module (35 mm) DIN device. 32 A C curve, 30 mA Type A earth leakage sensing and 6 kA breaking capacity on 230-240 V. Non-polarity-sensitive screw terminals to 25 mm2, IP2X, IEC 60898-1. In stock, ships in 24 hours.

Electrotraders USPs

Fast Shipping, Trusted by Government, Easy Returns, Free Shipping over $200


Description

32 A 1P+N safety switch, two module.

The Hager ADA932T combines MCB and RCD protection for a 32 A final circuit, switching both active and neutral in a robust 2 module (35 mm) device. It is the high-current 1P+N option in the two-module ADA range, ideal for retrofit where board space is limited.

Key Features

  • Hager ADA932T RCBO, 1 pole plus neutral, 2 module (35 mm) wide
  • 32 A rated current, C curve tripping characteristic
  • 30 mA rated residual operating current, Type A
  • 6 kA rated short circuit breaking capacity (Icn, IEC 60898-1)
  • 230 - 240 V AC rated operational voltage
  • Non-polarity-sensitive line and load terminals
  • Rated insulation voltage 500 V, impulse withstand 4 kV, energy limitation class 3
  • Built-in test button, screw terminals top and bottom
  • Accepts 1 - 25 mm² rigid or 1 - 16 mm² flexible conductors
  • Mounts on 35 mm DIN rail, IP2X rated
  • Bypass bottom connection for busbar wiring
  • Manufactured to IEC 60898-1, RoHS conform

Order yours - in stock and dispatched Australia-wide within 24 hours.

 

Two-Module 1P+N Protection

The ADA932T switches and protects both the active and the neutral conductor in a full-size 2 module (35 mm) body, height 83 mm and depth 68 mm. The wider format gives generous terminal access and takes rigid conductors up to 25 mm², matching the cable sizes a 32 A circuit typically runs. A built-in test button lets the installer verify the RCD function, and the unit resets easily once a fault is cleared.

Non-Polarity-Sensitive Terminals

The line and load terminals are non-polarity-sensitive, so the device operates regardless of which way the supply is connected. When replacing an RCBO from another brand you can reuse the existing wiring rather than swapping active and neutral, which cuts fault-finding and install time on site. A bypass bottom connection also supports insulated busbar wiring across a bank of devices.

32 A for Larger Circuits

The 32 A C curve rating suits higher-current final subcircuits: dedicated appliance and motor feeds, larger power circuits and sub-boards on single-phase supplies. The C curve tolerates the ordinary inrush of everyday equipment while tripping promptly on a genuine overload or short circuit.

Type A and Australian Conditions

As a Type A RCBO the ADA932T detects both sinusoidal AC and pulsating DC earth leakage, tripping at 30 mA. Rated operational voltage is 230 - 240 V, matching the Australian supply. Hager publishes a full derating curve: 32 A at 30 °C ambient, 31 A at 40 °C and 29 A at 60 °C, plus side-by-side correction factors when devices are grouped (0.95 for three units, 0.90 for four to five). Operating range -25 to 40 °C, rated to 2000 m altitude.

Q: Is the Hager ADA932T single pole or double pole?
A: It is a 1 pole plus neutral (1P+N) device that switches and protects both the active and neutral conductors. It occupies 2 modules (35 mm) of DIN rail. The single-module equivalent is the Hager ADC932T.

Q: Do I need to match polarity when wiring the ADA932T?
A: No. The line and load terminals are non-polarity-sensitive, so the device works regardless of supply orientation, and in most cases existing wiring can be reused when replacing another brand.

Q: Does the ADA932T have a test button?
A: Yes. It has an inbuilt test switch to verify the residual current function, and resets easily once the fault is rectified. As a Type A device it trips at 30 mA residual current.

(hagrcb2326k)

Specifications

Architecture
Type of pole 1P+N
Curve C
Electric current
Rated current 32 A
Rated residual operating current Idn 30 mA
Rated current -25DegC 38,30 A
Rated current at -20DegC 37,80 A
Rated current -15DegC 37,20 A
Rated current -10DegC 36,70 A
Rated current -5DegC 36,10 A
Rated current at 0DegC 35,60 A
Rated current 5DegC 35 A
Rated current 10DegC 34,40 A
Rated current 15DegC 33,80 A
Rated current at 20DegC 33,20 A
Rated current 25DegC 32,60 A
Rated current 30DegC 32 A
Rated current 35DegC 31,50 A
Rated current at 40DegC 31 A
Rated current at 50DegC 30 A
Rated current 55DegC 29,50 A
Rated current 60DegC 29 A
Correction factor of rating current for 2 devices placed side by side 1
Correction factor of rating current for 3 devices placed side by side 0,95
Correction factor of rating current for 4 and 5 devices placed side by side 0,90
Correction factor of rating current for 6 devices placed side by side 0,85
Min./max. threshold value of the AC thermal operation 1,13 - 1,45 A
Safety
Residual current type A
Ingress Protection (IP) class IP2X
Main electrical attributes
Rated short-circuit breaking capacity Icn AC according to IEC 60898-1 6 kA
Connectivity
Type of connection Screw terminal
Voltage
Rated insulation voltage Ui 500 V
Rated impulse withstand voltage Uimp 4000 V
Max. operating voltage 240 V
Rated operational voltage Ue 230 - 240 V
Overvoltage category according to IEC 60947-1 3
Power
Total power loss under IN 8,30 W
Frequency
Frequency 50 - 50 Hz
Use conditions
Max. Altitude 2000 m
Class of energy limitation I^2t 3
Operating temperature -25 - 40 DegC
Storage/transport temperature -25 - 70 DegC
Endurance
Electric endurance in number of cycles 2000
Number of mechanical operations 1000
Connection
Cross-section flexible conductor 1 - 16 mm^2
Cross-section rigid conductor 1 - 25 mm^2
Cross-section of input with screws, for flexible conductors 1 - 16 mm^2
Cross-section of input with screws, for massive conductors 1 - 25 mm^2
Cross-section of output with screws, for flexible conductors 1 - 16 mm^2
Cross-section of output with screws, for massive conductors 1 - 25 mm^2
Cross-section of input and output with screws, for flexible conductors 1 - 16 mm^2
Cross-section of input and output with screws, for massive conductors 1 - 25 mm^2
Installation, mounting
Nominal tightening torque 2,10 - 2,10 Nm
Type of top connection for modular devices Screw terminal
Type of bottom connection for modular devices biconnect, Bypass
Capacity
Number of modules 2
Dimensions
Height 83 mm
Width 35 mm
Depth 68 mm
Compatibility
Suitable for DIN Rail Yes
SKU hagrcb2326k
Manfacturer Part Number ADA932T
Barcode # 3250611011637
Brand Hager

Shipping Calculator