Hager ADA925T 25 Amps 1 Pole plus Neutral RCBO Safety Switch 6kA 30mA Type A C Curve 2 Module DIN Rail
SKU: hagrcb2256k
Product Image Gallery
Product Pricing
$39.31 (ex-GST)
$43.24 (inc-GST)
$43.24
$39.31
Stock and Availability
- ⚫︎ Ships in 24 hours
Hager ADA925T 1P+N RCBO in a 2 module (35 mm) DIN device. 25 A C curve, 30 mA Type A earth leakage sensing and 6 kA breaking capacity on 230-240 V. Non-polarity-sensitive screw terminals to 25 mm2, IP2X, IEC 60898-1. In stock, ships in 24 hours.
Electrotraders USPs
Description
25 A 1P+N safety switch, two module.
The Hager ADA925T combines MCB and RCD protection for a 25 A final circuit, switching both active and neutral in a robust 2 module (35 mm) device. It brings full 1P+N protection to single-phase power circuits, with a built-in RCD test button and non-polarity-sensitive terminals.
Key Features
- Hager ADA925T RCBO, 1 pole plus neutral, 2 module (35 mm) wide
- 25 A rated current, C curve tripping characteristic
- 30 mA rated residual operating current, Type A
- 6 kA rated short circuit breaking capacity (Icn, IEC 60898-1)
- 230 - 240 V AC rated operational voltage
- Non-polarity-sensitive line and load terminals
- Rated insulation voltage 500 V, impulse withstand 4 kV, energy limitation class 3
- Built-in test button, screw terminals top and bottom
- Accepts 1 - 25 mm² rigid or 1 - 16 mm² flexible conductors
- Mounts on 35 mm DIN rail, IP2X rated
- Bypass bottom connection for busbar wiring
- Manufactured to IEC 60898-1, RoHS conform
Shop online - in stock and dispatched Australia-wide within 24 hours.
Two-Module 1P+N Protection
The ADA925T switches and protects both the active and the neutral conductor in a full-size 2 module (35 mm) body, height 83 mm and depth 68 mm. The wider format gives generous terminal access and takes rigid conductors up to 25 mm², matching the cable sizes a 25 A circuit typically runs. A built-in test button lets the installer verify the RCD function, and the unit resets easily once a fault is cleared.
Non-Polarity-Sensitive Terminals
The line and load terminals are non-polarity-sensitive, so the device operates regardless of which way the supply is connected. When replacing an RCBO from another brand you can reuse the existing wiring rather than swapping active and neutral, which cuts fault-finding and install time on site. A bypass bottom connection also supports insulated busbar wiring across a bank of devices.
25 A for Larger Final Circuits
The 25 A C curve rating suits higher-current final subcircuits: larger socket circuits, mixed power loads and dedicated appliance feeds on single-phase supplies. The C curve tolerates the ordinary inrush of everyday equipment while tripping promptly on a genuine overload or short circuit.
Type A and Australian Conditions
As a Type A RCBO the ADA925T detects both sinusoidal AC and pulsating DC earth leakage, tripping at 30 mA. Rated operational voltage is 230 - 240 V, matching the Australian supply. Hager publishes a full derating curve: 25 A at 30 °C ambient, 24.50 A at 40 °C and 23.50 A at 60 °C, plus side-by-side correction factors when devices are grouped (0.95 for three units, 0.90 for four to five). Operating range -25 to 40 °C, rated to 2000 m altitude.
Q: Is the Hager ADA925T single pole or double pole?
A: It is a 1 pole plus neutral (1P+N) device that switches and protects both the active and neutral conductors. It occupies 2 modules (35 mm) of DIN rail. The single-module equivalent is the Hager ADC925T.
Q: Do I need to match polarity when wiring the ADA925T?
A: No. The line and load terminals are non-polarity-sensitive, so the device works regardless of supply orientation, and in most cases existing wiring can be reused when replacing another brand.
Q: Does the ADA925T have a test button?
A: Yes. It has an inbuilt test switch to verify the residual current function, and resets easily once the fault is rectified. As a Type A device it trips at 30 mA residual current.
(hagrcb2256k)
Specifications
| Architecture | |
| Type of pole | 1P+N |
| Curve | C |
| Electric current | |
| Rated current | 25 A |
| Rated residual operating current Idn | 30 mA |
| Rated current -25DegC | 28,20 A |
| Rated current at -20DegC | 27,90 A |
| Rated current -15DegC | 27,60 A |
| Rated current -10DegC | 27,40 A |
| Rated current -5DegC | 27,10 A |
| Rated current at 0DegC | 26,80 A |
| Rated current 5DegC | 26,50 A |
| Rated current 10DegC | 26,20 A |
| Rated current 15DegC | 25,90 A |
| Rated current at 20DegC | 25,60 A |
| Rated current 25DegC | 25,30 A |
| Rated current 30DegC | 25 A |
| Rated current 35DegC | 24,80 A |
| Rated current at 40DegC | 24,50 A |
| Rated current at 50DegC | 24 A |
| Rated current 55DegC | 23,80 A |
| Rated current 60DegC | 23,50 A |
| Correction factor of rating current for 2 devices placed side by side | 1 |
| Correction factor of rating current for 3 devices placed side by side | 0,95 |
| Correction factor of rating current for 4 and 5 devices placed side by side | 0,90 |
| Correction factor of rating current for 6 devices placed side by side | 0,85 |
| Min./max. threshold value of the AC thermal operation | 1,13 - 1,45 A |
| Safety | |
| Residual current type | A |
| Ingress Protection (IP) class | IP20 |
| Main electrical attributes | |
| Rated short-circuit breaking capacity Icn AC according to IEC 60898-1 | 6 kA |
| Connectivity | |
| Type of connection | Screw terminal |
| Voltage | |
| Rated insulation voltage Ui | 500 V |
| Rated impulse withstand voltage Uimp | 4000 V |
| Max. operating voltage | 240 V |
| Rated operational voltage Ue | 230 - 240 V |
| Overvoltage category according to IEC 60947-1 | 3 |
| Power | |
| Total power loss under IN | 9,30 W |
| Frequency | |
| Frequency | 50 - 50 Hz |
| Use conditions | |
| Max. Altitude | 2000 m |
| Class of energy limitation I^2t | 3 |
| Operating temperature | -25 - 40 DegC |
| Storage/transport temperature | -25 - 70 DegC |
| Endurance | |
| Electric endurance in number of cycles | 2000 |
| Number of mechanical operations | 2000 |
| Connection | |
| Cross-section flexible conductor | 1 - 16 mm^2 |
| Cross-section rigid conductor | 1 - 25 mm^2 |
| Cross-section of input with screws, for flexible conductors | 1 - 16 mm^2 |
| Cross-section of input with screws, for massive conductors | 1 - 25 mm^2 |
| Cross-section of output with screws, for flexible conductors | 1 - 16 mm^2 |
| Cross-section of output with screws, for massive conductors | 1 - 25 mm^2 |
| Cross-section of input and output with screws, for flexible conductors | 1 - 16 mm^2 |
| Cross-section of input and output with screws, for massive conductors | 1 - 25 mm^2 |
| Installation, mounting | |
| Nominal tightening torque | 2,10 - 2,10 Nm |
| Type of top connection for modular devices | Screw terminal |
| Type of bottom connection for modular devices | biconnect, Bypass |
| Capacity | |
| Number of modules | 2 |
| Dimensions | |
| Height | 83 mm |
| Width | 35 mm |
| Depth | 68 mm |
| Compatibility | |
| Suitable for DIN Rail | Yes |
| SKU | hagrcb2256k |
| Manfacturer Part Number | ADA925T |
| Barcode # | 3250611011620 |
| Brand | Hager |