Hager ADD206B RCBO Safety Switch 6A 1 Pole D Curve 10kA 30mA Type A 1 Module DIN Rail 230V

SKU: hagrcb10610kd

Product Image Gallery

Product image thumbnail for SKU hagrcb10610kd

Product Pricing

$200.81 (ex-GST)

$220.89 (inc-GST)

$220.89

$200.81

(inc-GST)
(ex-GST)

Stock and Availability

  • ⚫︎ Ships in 2-5 days

Hager ADD206B 6A single-pole RCBO safety switch combining MCB and RCD protection: D-curve overcurrent, 10kA breaking, 30mA Type A earth leakage. Compact 1-module DIN rail device. AS/NZS 61009 compliant.

Electrotraders USPs

Fast Shipping, Trusted by Government, Easy Returns, Free Shipping over $200


Description

Overcurrent and earth-leakage protection in one module.

The Hager ADD206B is a 6A single-pole RCBO (residual current breaker with overcurrent protection) combining D-curve overload and short-circuit protection with 30mA Type A earth-leakage protection in a compact 1-module DIN rail device.

Key Features

  • Rated current: 6A, single pole (1P)
  • D tripping curve (10–20x In) for high-inrush loads
  • 10kA breaking capacity (Icn) to IEC 60898-1
  • 30mA residual current, Type A (detects AC and pulsating DC)
  • Rated voltage 230–240V AC; insulation voltage 250V
  • Compact 1-module width (17.8mm) DIN rail mount
  • Accepts conductors 1–25mm² rigid, 1–16mm² flexible
  • IP20; rated impulse withstand 4000V

Order today – fast dispatch on Hager safety switches Australia-wide.

 

Why it Matters

Two protections in a single device.
The ADD206B is an RCBO – a residual current breaker with overcurrent protection – combining the functions of an MCB and an RCD in one module. It protects a circuit against overload and short circuit and, at the same time, disconnects on an earth-leakage fault of 30mA or more, guarding against electric shock. Combining both roles in one 1-module device saves board space compared with separate MCB and RCD components.

D curve and Type A leakage detection.
The D tripping characteristic trips on short circuit at 10 to 20 times rated current, suited to circuits with high inrush – transformers, motors and switch-mode supplies – that would nuisance-trip a standard C-curve device. Its Type A residual sensing detects both AC and pulsating DC earth-leakage currents, covering modern electronic loads, and its 10kA breaking capacity handles the fault levels found in commercial and industrial switchboards.

Built for Australian switchboards.
At one module (17.8mm) wide, 115mm high and 70mm deep, the ADD206B clips onto standard 35mm DIN rail. Terminals take rigid conductors up to 25mm², and it is rated IP20 with a 4kV impulse withstand. It complies with AS/NZS 61009 for RCBOs and suits residential, commercial and industrial final circuits requiring combined overcurrent and earth-leakage protection.

Q: What is an RCBO and how is the ADD206B different from an MCB?
An RCBO combines an MCB and an RCD in one device: it protects against overload and short circuit like an MCB, and also trips on earth leakage (30mA here) to guard against electric shock – protection a plain MCB does not provide.

Q: What does the D curve mean on the ADD206B?
The D curve trips on short circuit at 10 to 20 times the rated current, suited to high-inrush loads such as transformers and motors that would nuisance-trip a lower B or C curve.

Q: What does Type A mean on the ADD206B?
Type A residual current detection responds to both AC and pulsating DC earth-leakage currents, covering electronic loads that a basic Type AC device may not detect.

(hagrcb10610kd)

Specifications

Architecture
Type of pole 1P
Curve D
Electric current
Rated current 6 A
Rated residual operating current Idn 30 mA
Rated current -25DegC 7,79 A
Rated current at -20DegC 7,63 A
Rated current -15DegC 7,46 A
Rated current -10DegC 7,30 A
Rated current -5DegC 7,14 A
Rated current at 0DegC 6,98 A
Rated current 5DegC 6,81 A
Rated current 10DegC 6,65 A
Rated current 15DegC 6,49 A
Rated current at 20DegC 6,33 A
Rated current 25DegC 6,16 A
Rated current 30DegC 6 A
Rated current 35DegC 5,98 A
Rated current at 40DegC 5,95 A
Rated current at 50DegC 5,90 A
Rated current 55DegC 5,88 A
Rated current 60DegC 5,85 A
Min./max. threshold value of the AC thermal operation 1,13 - 1,45 A
Safety
Residual current type A
Ingress Protection (IP) class IP20
Main electrical attributes
Rated short-circuit breaking capacity Icn AC according to IEC 60898-1 10 kA
Voltage
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 4000 V
Rated operational voltage Ue 230 - 240 V
Overvoltage category according to IEC 60947-1 3
Power
Total power loss under IN 2 W
Frequency
Frequency 50 - 60 Hz
Use conditions
Max. Altitude 2000 m
Operating temperature -5 - 40 DegC
Storage/transport temperature -40 - 70 DegC
Endurance
Electric endurance in number of cycles 2000
Number of mechanical operations 10000
Connection
Cross-section of input with screws, for flexible conductors 1 - 10 mm^2
Cross-section of input with screws, for massive conductors 1 - 16 mm^2
Cross-section of input and output with screws, for flexible conductors 1 - 16 mm^2
Cross-section of input and output with screws, for massive conductors 1 - 25 mm^2
Installation, mounting
Type of top connection for modular devices Screw terminal
Type of bottom connection for modular devices biconnect
Capacity
Number of modules 1
Dimensions
Height 115 mm
Width 17,80 mm
Depth 70 mm
Compatibility
Suitable for DIN Rail Yes
SKU hagrcb10610kd
Manfacturer Part Number ADD206B
Barcode # 3250611035138
Brand Hager

Shipping Calculator