Hager ADC916T RCBO Safety Switch 16A 1P+N C Curve 6kA 30mA Type A 1 Module DIN Rail 230V

SKU: hagrcb1166k

Product Image Gallery

Product image thumbnail for SKU hagrcb1166k

Product Pricing

$40.00 (ex-GST)

$44.00 (inc-GST)

$44.00

$40.00

(inc-GST)
(ex-GST)

Stock and Availability

  • ⚫︎ Only 4 Left!

Hager ADC916T 16A single-pole-plus-neutral (1P+N) RCBO safety switch combining MCB and RCD protection: C-curve overcurrent, 6kA breaking, 30mA Type A earth leakage. Compact 1-module DIN rail device. AS/NZS 61009 compliant.

Electrotraders USPs

Fast Shipping, Trusted by Government, Easy Returns, Free Shipping over $200


Description

Active and neutral protection in one module.

The Hager ADC916T is a 16A single-pole-plus-neutral (1P+N) RCBO combining C-curve overload and short-circuit protection with 30mA Type A earth-leakage protection, switching both active and neutral in a compact 1-module DIN rail device.

Key Features

  • Rated current: 16A, single pole plus neutral (1P+N)
  • C tripping curve (5–10x In)
  • 6kA breaking capacity (Icn) to IEC 60898-1
  • 30mA residual current, Type A (detects AC and pulsating DC)
  • Rated voltage 230–240V AC (max 264V); insulation voltage 440V
  • Compact 1-module width (17.7mm) DIN rail mount
  • Accepts conductors 1–16mm² rigid, 1–10mm² flexible
  • IP2X; 20,000 mechanical / 10,000 electrical operations

Buy online now – fast dispatch on Hager safety switches Australia-wide.

 

Why it Matters

Switches active and neutral together.
The ADC916T is a 1P+N RCBO – a residual current breaker with overcurrent protection that switches both the active and neutral conductors. It combines the functions of an MCB and an RCD in one module: protecting the circuit against overload and short circuit, and disconnecting on a 30mA earth-leakage fault to guard against electric shock. Because it breaks the neutral as well as the active, it fully isolates the final circuit for safe working.

C curve and Type A leakage detection.
The C tripping characteristic trips on short circuit at 5 to 10 times rated current, the general-purpose curve suited to the mixed resistive and moderately inductive loads on most power-point and appliance circuits – where a 16A rating is one of the most common sizes. Its Type A residual sensing detects both AC and pulsating DC earth-leakage currents, covering modern electronic loads, and its 6kA breaking capacity suits the fault levels found in residential and light commercial switchboards.

Built for Australian switchboards.
At one module (17.7mm) wide, 85mm high and 70mm deep, the ADC916T clips onto standard 35mm DIN rail. Terminals take conductors up to 16mm², it is rated IP2X with a 4kV impulse withstand, and it operates from -25°C to 70°C – a wider range than earlier RCBOs – with 20,000 mechanical and 10,000 electrical operations of endurance. It complies with AS/NZS 61009 for RCBOs and suits residential and light commercial final circuits.

Q: What does 1P+N mean on the Hager ADC916T?
1P+N means the device protects and switches one active pole plus the neutral, breaking both conductors together to fully isolate the circuit – while still occupying just one DIN module.

Q: What is an RCBO and how is it different from an MCB?
An RCBO combines an MCB and an RCD in one device: it protects against overload and short circuit like an MCB, and also trips on earth leakage (30mA here) to guard against electric shock – protection a plain MCB does not provide.

Q: What does Type A mean on the ADC916T?
Type A residual current detection responds to both AC and pulsating DC earth-leakage currents, covering electronic loads that a basic Type AC device may not detect.

(hagrcb1166k)

Specifications

Architecture
Type of pole 1P+N
Curve C
Electric current
Rated current 16 A
Rated residual operating current Idn 30 mA
Rated current -25DegC 20,50 A
Rated current at -20DegC 20,10 A
Rated current -15DegC 19,70 A
Rated current -10DegC 19,30 A
Rated current -5DegC 18,90 A
Rated current at 0DegC 18,50 A
Rated current 5DegC 18,10 A
Rated current 10DegC 17,60 A
Rated current 15DegC 17,20 A
Rated current at 20DegC 16,80 A
Rated current 25DegC 16,40 A
Rated current 30DegC 16 A
Rated current 35DegC 15,70 A
Rated current at 40DegC 15,50 A
Rated current at 50DegC 15 A
Rated current 55DegC 14,70 A
Rated current 60DegC 14,50 A
Min./max. threshold value of the AC thermal operation 1,13 - 1,45 A
Safety
Residual current type A
Ingress Protection (IP) class IP2X
Main electrical attributes
Rated short-circuit breaking capacity Icn AC according to IEC 60898-1 6 kA
Voltage
Rated insulation voltage Ui 440 V
Rated impulse withstand voltage Uimp 4000 V
Max. operating voltage 264 V
Rated operational voltage Ue 230 - 240 V
Overvoltage category according to IEC 60947-1 3
Power
Total power loss under IN 8,69 W
Frequency
Frequency 50 - 50 Hz
Use conditions
Max. Altitude 2000 m
Class of energy limitation I^2t 3
Operating temperature -25 - 70 DegC
Storage/transport temperature -25 - 80 DegC
Endurance
Electric endurance in number of cycles 10000
Number of mechanical operations 20000
Connection
Cross-section of input with screws, for flexible conductors 1 - 10 mm^2
Cross-section of input with screws, for massive conductors 1 - 16 mm^2
Cross-section of input and output with screws, for flexible conductors 1 - 10 mm^2
Cross-section of input and output with screws, for massive conductors 1 - 16 mm^2
Installation, mounting
Type of top connection for modular devices Screw terminal
Type of bottom connection for modular devices biconnect
Capacity
Number of modules 1
Dimensions
Height 85 mm
Width 17,70 mm
Depth 70 mm
Compatibility
Suitable for DIN Rail Yes
SKU hagrcb1166k
Manfacturer Part Number ADC916T
Barcode # 3250611033356
Brand Hager