Hager ADD925T 25 Amps 1 Pole plus Neutral D Curve RCBO Safety Switch 6kA 30mA Type A 1 Module DIN Rail

SKU: hagrcb1256kd

Product Image Gallery

Product image thumbnail for SKU hagrcb1256kd
Product image thumbnail for SKU hagrcb1256kd
Product image thumbnail for SKU hagrcb1256kd
Product image thumbnail for SKU hagrcb1256kd
Product image thumbnail for SKU hagrcb1256kd

Product Pricing

$131.25 (ex-GST)

$144.38 (inc-GST)

$144.38

$131.25

(inc-GST)
(ex-GST)

Stock and Availability

  • ⚫︎ Ships in 24 hours

Hager ADD925T 1P+N RCBO in a slim 17.7 mm DIN module. 25 A D curve for high-inrush loads, 30 mA Type A earth leakage sensing and 6 kA breaking capacity on 230-240 V. Screw and BIconnect terminals, IP20, IEC 60898-1. In stock, ships in 24 hours.

Electrotraders USPs

Fast Shipping, Trusted by Government, Easy Returns, Free Shipping over $200


Description

D curve neutral switching in one slim module.

The Hager ADD925T combines a D curve tripping characteristic with true 1P+N neutral switching, all in a single 17.7 mm module. It handles high-inrush loads that need both the active and neutral switched, without taking a second module of DIN rail.

Key Features

  • Hager ADD925T RCBO, 1 pole plus neutral, 1 module (17.7 mm) wide
  • 25 A rated current, D curve tripping characteristic
  • 30 mA rated residual operating current, Type A
  • 6 kA rated short circuit breaking capacity (Icn, IEC 60898-1)
  • 230 - 240 V AC rated operational voltage, 50 - 60 Hz
  • Rated insulation voltage 440 V, impulse withstand 4 kV, energy limitation class 3
  • Screw terminal top, BIconnect bottom connection
  • Accepts 1 - 16 mm² solid or 1 - 10 mm² flexible conductors
  • Mounts on 35 mm DIN rail, IP20 rated
  • Wide operating range: -25 to 70 °C
  • 20,000 mechanical operations, 10,000 electrical cycles
  • Manufactured to IEC 60898-1, RoHS conform

Order online - in stock and dispatched Australia-wide within 24 hours.

 

Why the D Curve

A D curve breaker tolerates inrush currents of roughly 10 to 20 times its rated current before magnetic tripping, against 5 to 10 times for a C curve. That headroom keeps the circuit live through the brief current spike when motors, transformers, welders and large switch-mode supplies energise. Choose the ADD925T where a C curve RCBO nuisance-trips on start-up but you still need 30 mA earth leakage protection with the neutral switched.

1P+N Protection, Single Module

The ADD925T switches and protects both the active and the neutral conductor. Traditionally that meant a two-module device, but this slimline design does it in one 17.7 mm module, height 85 mm and depth 70 mm, so it fits standard flush and surface switchboards while freeing rail space. The screw top terminal and BIconnect bottom terminal align it with the rest of a Hager modular assembly.

Type A Earth Leakage Sensing

As a Type A RCBO the ADD925T detects both sinusoidal AC earth leakage and pulsating DC earth leakage, unlike Type AC which detects only the AC component. With inverters, variable speed drives and switch mode supplies now common on Australian final circuits, Type A is the practical baseline. It trips at a rated residual current of 30 mA.

Rated for Australian Conditions

Rated operational voltage is 230 - 240 V at 50 - 60 Hz, matching the Australian supply, with a maximum operating voltage of 264 V. Hager publishes a full derating curve: 25 A at 30 °C ambient, 23.70 A at 40 °C and 21 A at 60 °C, relevant where meter boxes and plant rooms run hot. The device is rated to 2000 m altitude.

Q: What is the difference between the Hager ADD925T and the ADC925T?
A: Both are 25A 1P+N 6kA 30mA Type A RCBOs in a single module. The ADD925T has a D curve for high-inrush loads like motors and transformers, while the ADC925T has a C curve for general circuits. The D curve resists nuisance tripping on start-up surges.

Q: Is the Hager ADD925T single pole or double pole?
A: It is a 1 pole plus neutral (1P+N) device that switches and protects both the active and neutral conductors, in a single 17.7 mm module.

Q: Does the ADD925T detect DC earth leakage?
A: Yes. As a Type A RCBO it detects both sinusoidal AC and pulsating DC residual currents, tripping at 30 mA. It does not detect smooth DC leakage, which requires a Type B device.

(hagrcb1256kd)

Specifications

Architecture
Type of pole 1P+N
Curve D
Electric current
Rated current 25 A
Rated residual operating current Idn 30 mA
Rated current -25DegC 32,40 A
Rated current at -20DegC 31,70 A
Rated current -15DegC 31,10 A
Rated current -10DegC 30,40 A
Rated current -5DegC 29,70 A
Rated current at 0DegC 29 A
Rated current 5DegC 28,40 A
Rated current 10DegC 27,70 A
Rated current 15DegC 27 A
Rated current at 20DegC 26,30 A
Rated current 25DegC 25,70 A
Rated current 30DegC 25 A
Rated current 35DegC 24,30 A
Rated current at 40DegC 23,70 A
Rated current at 50DegC 22,30 A
Rated current 55DegC 21,60 A
Rated current 60DegC 21 A
Min./max. threshold value of the AC thermal operation 1,13 - 1,45 A
Safety
Residual current type A
Ingress Protection (IP) class IP20
Main electrical attributes
Rated short-circuit breaking capacity Icn AC according to IEC 60898-1 6 kA
Voltage
Rated insulation voltage Ui 440 V
Rated impulse withstand voltage Uimp 4000 V
Max. operating voltage 264 V
Rated operational voltage Ue 230 - 240 V
Overvoltage category according to IEC 60947-1 3
Power
Total power loss under IN 11,38 W
Frequency
Frequency 50 - 50 Hz
Use conditions
Max. Altitude 2000 m
Class of energy limitation I^2t 3
Operating temperature -25 - 70 DegC
Storage/transport temperature -25 - 80 DegC
Endurance
Electric endurance in number of cycles 10000
Number of mechanical operations 20000
Connection
Cross-section of input with screws, for flexible conductors 1 - 10 mm^2
Cross-section of input with screws, for massive conductors 1 - 16 mm^2
Cross-section of input and output with screws, for flexible conductors 1 - 10 mm^2
Cross-section of input and output with screws, for massive conductors 1 - 16 mm^2
Installation, mounting
Type of top connection for modular devices Screw terminal
Type of bottom connection for modular devices biconnect
Capacity
Number of modules 1
Dimensions
Height 85 mm
Width 17,70 mm
Depth 70 mm
Compatibility
Suitable for DIN Rail Yes
SKU hagrcb1256kd
Manfacturer Part Number ADD925T
Barcode # 3250611033448
Brand Hager

Shipping Calculator