Hager SBR390 Modular Switch Disconnector Isolator 100A 3 Pole 400V 3 Module Red Toggle DIN Rail
SKU: hagisoswi3100
Product Image Gallery
Product Pricing
$66.19 (ex-GST)
$72.81 (inc-GST)
$72.81
$66.19
Stock and Availability
- ⚫︎ Ships in 24 hours
Hager SBR390 100A three-pole modular switch disconnector (isolator) with red toggle. Compact 3-module DIN rail design for safe manual isolation of three-phase circuits at 400V. Rated AC22A 100A, IP20, 6kV impulse, 50mm2 terminals.
Electrotraders USPs
Description
Three-phase 100A isolation, one clear toggle.
The Hager SBR390 is a 100A three-pole modular switch disconnector (isolator) with a red toggle, giving safe, visible manual isolation of a three-phase 400V circuit from a compact 3-module DIN rail body.
Key Features
- Rated current: 100A, three-phase (3P)
- Red toggle switch disconnector; 3NO poles
- Utilisation category AC22A (and AC21A) at 100A
- Rated voltage 400V AC, insulation voltage 440V
- 3-module width (52.5mm) DIN rail mount
- High-capacity terminals: rigid 6–50mm², flexible 6–35mm²
- Rated impulse withstand voltage 6000V; IP20; IEC 60947-3
- Icm 1.69kA making, Icw 1.2kA short-time withstand
Buy online now – fast dispatch on Hager switchgear Australia-wide.
Why it Matters
Isolate all three phases at once.
The SBR390 is a three-pole switch disconnector, not a circuit breaker – its role is to positively disconnect all three phases of a 400V circuit together for maintenance and safe working, with the red toggle giving clear on/off indication at the board. Rated for AC22A duty at 100A to IEC 60947-3, it makes and breaks mixed resistive and inductive loads, backed by a strong 1.69kA making capacity and 1.2kA short-time withstand for demanding three-phase feeds.
Heavy three-phase cable, three modules.
The SBR390 spans three DIN modules (52.5mm wide, 83mm high, 68mm deep) on standard 35mm rail. Its high-capacity terminals take rigid conductors from 6 up to 50mm² and flexible from 6 up to 35mm² per pole at a 3.6Nm tightening torque – sized for the sub-main cabling a 100A three-phase feed runs – and it is rated for 40,000 mechanical operations for long service life.
Built for Australian switchboards.
With a 6kV rated impulse withstand voltage and IP20 protection, the SBR390 operates from -20°C to 70°C, covering meter boxes, plant rooms and commercial and industrial distribution boards across Australian conditions on standard 35mm DIN rail. Optional Hager accessories include the MZN175 padlockable locking kit for safe lock-off, MZN121 inter-pole barriers, MZN120 terminal shield, KRN199 neutral connecting block and the ESC080 auxiliary contact.
Q: Is the Hager SBR390 a circuit breaker?
No. It is a three-pole switch disconnector (isolator) for safe manual on/off isolation of a three-phase circuit; it does not provide automatic overload or short-circuit tripping like an MCCB.
Q: What voltage and load is the SBR390 rated for?
400V AC three-phase at 100A under the AC21A/AC22A utilisation categories, covering resistive and mixed inductive loads.
Q: What cable can the SBR390 terminals take?
Rigid conductors from 6 to 50mm² and flexible from 6 to 35mm² per pole, tightened to 3.6Nm – sized for a 100A three-phase sub-main.
(hagisoswi3100)
Specifications
| Architecture | |
| Number of poles | 3 |
| Neutral position | Without neutral |
| Type of pole | 3P |
| Electric current | |
| Rated current | 100 A |
| Rated conditional short-circuit current Icc with gl-gG fuses | 1,20 kA |
| Acceptable current rating AC21 category A | 100 A |
| Acceptable current rating AC21 category B | 100 A |
| Acceptable current rating AC22 category A | 100 A |
| Acceptable current rating AC22 category B | 100 A |
| Rated short-circuit making capacity Icm under 415 V AC according to IEC 60947-3 | 1,69 kA |
| Rated short-time withstand current Icw 1s IEC 60947 | 1,20 kA |
| Installation, mounting | |
| Nominal tightening torque | 3,60 - 3,60 Nm |
| Type of bottom connection for modular devices | Screw terminal |
| Voltage | |
| Rated operational voltage Ue | 400 - 400 V |
| Type voltage supply | AC |
| Rated insulation voltage Ui | 440 V |
| Rated impulse withstand voltage Uimp | 6000 V |
| Capacity | |
| Number of modules | 3 |
| Safety | |
| Ingress Protection (IP) class | IP20 |
| Frequency | |
| Frequency | 50 - 60 Hz |
| Dimensions | |
| Height | 83 mm |
| Width | 52,50 mm |
| Depth | 68 mm |
| Equipment | |
| Number of NO contacts | 3 |
| Number of NC contacts | 0 |
| Use conditions | |
| Operating temperature | -20 - 70 DegC |
| Storage/transport temperature | -40 - 80 DegC |
| Connection | |
| Cross-section flexible conductor | 6 - 35 mm^2 |
| Cross-section rigid conductor | 6 - 50 mm^2 |
| Endurance | |
| Number of mechanical operations | 40000 |
| Electrical durability at nominal load in AC21 in operating cycles | 2500 |
| Electrical durability at nominal load in AC22 in operating cycles | 2500 |
| Power | |
| Total power loss under IN | 16,50 W |
| Power loss per pole at In | 5,50 W |
| Connectivity | |
| Down connection alignment for modular devices | Aligned terminal |
| Top connection alignment for modular devices | Aligned terminal |
| SKU | hagisoswi3100 |
| Manfacturer Part Number | SBR390 |
| Barcode # | 3250615510471 |
| Brand | Hager |