Hager SBR180 Modular Switch Disconnector Isolator 80A 1 Pole 230V 1 Module Red Toggle DIN Rail

SKU: hagisoswi180

Product Image Gallery

Product image thumbnail for SKU hagisoswi180

Product Pricing

$11.44 (ex-GST)

$12.58 (inc-GST)

$12.58

$11.44

(inc-GST)
(ex-GST)

Stock and Availability

  • ⚫︎ Ships in 24 hours

Hager SBR180 80A single-pole modular switch disconnector (isolator) with red toggle. Compact 1-module DIN rail design with 50mm2 terminals for safe manual isolation of single-phase circuits. Rated AC22A 80A, IP20, 6kV impulse withstand.

Electrotraders USPs

Fast Shipping, Trusted by Government, Easy Returns, Free Shipping over $200


Description

80A main-switch isolation in one module.

The Hager SBR180 is an 80A single-pole modular switch disconnector (isolator) with a red toggle, giving safe, visible manual isolation of a single-phase main or sub-circuit from a compact 1-module DIN rail body.

Key Features

  • Rated current: 80A
  • Single pole (1P), red toggle switch disconnector
  • Utilisation category AC22A (and AC21A) at 80A
  • Rated voltage 230V AC, insulation voltage 440V
  • Compact 1-module width (17.5mm) DIN rail mount
  • High-capacity terminals: rigid 6–50mm², flexible 6–35mm²
  • Rated impulse withstand voltage 6000V; IP20; IEC 60947-3
  • Icm 1.35kA making, Icw 0.96kA short-time withstand

Add to cart – order online for fast dispatch on Hager switchgear Australia-wide.

 

Why it Matters

Isolation you can see.
The SBR180 is a switch disconnector, not a circuit breaker – its role is to positively disconnect a circuit for maintenance and safe working, with the red toggle giving clear on/off indication at the board. Rated for AC22A duty at 80A to IEC 60947-3, it makes and breaks mixed resistive and inductive loads, backed by a 1.35kA making capacity and 0.96kA short-time withstand – suited to main-switch and sub-main isolation rather than automatic tripping.

Heavy cable, single module.
Despite its 80A rating the SBR180 takes just one DIN module (17.5mm wide, 83mm high, 68mm deep) on standard 35mm rail. Its high-capacity terminals accept rigid conductors from 6 up to 50mm² and flexible from 6 up to 35mm² at a 3.6Nm tightening torque – the larger cable an 80A sub-main runs – while dissipating only 2.7W and lasting 40,000 mechanical operations.

Built for Australian boards.
With a 6kV rated impulse withstand voltage and IP20 protection, the SBR180 operates from -20°C to 70°C, covering meter boxes, plant rooms and enclosures across Australian conditions on standard 35mm DIN rail. Optional Hager accessories include the MZN175 padlockable locking kit for safe lock-off during isolation, MZN121 inter-pole barriers, MZN120 terminal shield and the ESC080 auxiliary contact.

Q: Is the Hager SBR180 a circuit breaker?
No. It is a switch disconnector (isolator) for safe manual on/off isolation of a circuit; it does not provide automatic overload or short-circuit tripping like an MCB.

Q: What cable can the SBR180 terminals take?
Rigid conductors from 6 to 50mm² and flexible from 6 to 35mm², tightened to 3.6Nm – high-capacity terminals sized for an 80A sub-main.

Q: What does AC22A mean on the SBR180?
AC22A is a utilisation category for switching mixed resistive and inductive loads, meaning the SBR180 is rated to make and break such loads at its full 80A rating.

(hagisoswi180)

Specifications

Architecture
Number of poles 1
Neutral position Without neutral
Type of pole 1P
Electric current
Rated current 80 A
Rated conditional short-circuit current Icc with gl-gG fuses 0,96 kA
Acceptable current rating AC21 category A 80 A
Acceptable current rating AC21 category B 80 A
Acceptable current rating AC22 category A 80 A
Acceptable current rating AC22 category B 80 A
Rated short-circuit making capacity Icm under 240 V AC according to IEC 60947-3 1,35 kA
Rated short-time withstand current Icw 1s IEC 60947 0,96 kA
Installation, mounting
Nominal tightening torque 3,60 - 3,60 Nm
Type of bottom connection for modular devices Screw terminal
Voltage
Rated operational voltage Ue 230 - 230 V
Type voltage supply AC
Rated insulation voltage Ui 440 V
Rated impulse withstand voltage Uimp 6000 V
Capacity
Number of modules 1
Safety
Ingress Protection (IP) class IP20
Frequency
Frequency 50 - 60 Hz
Dimensions
Height 83 mm
Width 17,50 mm
Depth 68 mm
Equipment
Number of NO contacts 1
Number of NC contacts 0
Use conditions
Operating temperature -20 - 70 DegC
Storage/transport temperature -40 - 80 DegC
Connection
Cross-section flexible conductor 6 - 35 mm^2
Cross-section rigid conductor 6 - 50 mm^2
Endurance
Number of mechanical operations 40000
Electrical durability at nominal load in AC21 in operating cycles 2500
Electrical durability at nominal load in AC22 in operating cycles 2500
Power
Total power loss under IN 2,70 W
Power loss per pole at In 2,70 W
Connectivity
Down connection alignment for modular devices Aligned terminal
Top connection alignment for modular devices Aligned terminal
SKU hagisoswi180
Manfacturer Part Number SBR180
Barcode # 3250615510426
Brand Hager

Shipping Calculator