Hager CDA440T RCCB Safety Switch 40A 4 Pole (3P+N) 30mA Type A 230/400V AC 4 Module IP20 DIN Rail

SKU: hagrcd440

Product Image Gallery

Product image thumbnail for SKU hagrcd440

Product Pricing

$40.00 (ex-GST)

$44.00 (inc-GST)

$44.00

$40.00

(inc-GST)
(ex-GST)

Bulk Carton size

 36

Stock and Availability

  • ⚫︎ Only 1 Left!

Hager CDA440T residual current circuit breaker: 4 pole (3P+N), 40A, 30mA Type A sensing for AC and pulsating DC earth faults. 230/400V AC, 440V max, 6kA conditional short-circuit rating, 4 modules, IP20. Earth leakage protection only, no overcurrent.

Electrotraders USPs

Fast Shipping, Trusted by Government, Easy Returns, Free Shipping over $200


Description

Four-pole earth leakage protection for 400V boards.

The Hager CDA440T is a 40A residual current circuit breaker with 30mA Type A sensing across three phases and neutral. It disconnects the circuit when leakage to earth reaches its trip threshold, covering both AC and pulsating DC residual currents in a 4 module DIN rail body.

Key Features

  • 4 pole (3P+N), 40A rated current
  • 30mA rated residual operating current
  • Type A sensing: AC and pulsating DC residual currents
  • 230/400V AC, 50Hz, 440V maximum operating voltage
  • 6kA conditional short-circuit current (Inc) to EN 61008-1
  • 1.5kA breaking and opening capacity (Idm)
  • 4 modules: 70mm wide, 83mm high, 70mm deep
  • Screw top terminals, biconnect bottom, 2.8Nm torque
  • IP20, 6.5W power loss at rated current
  • 2,000 electrical cycles, 4,000 mechanical operations

Buy online today – quick dispatch from our Australian warehouse.

 

Specifying the CDA440T in a Three-Phase Board

An RCCB is not a circuit breaker
This is an important distinction at ordering time. An RCCB provides residual current (earth leakage) protection only. It does not protect cabling against overload or short-circuit, so upstream or downstream overcurrent protection is still required. Hager's 6kA figure is a conditional short-circuit rating, meaning the device withstands that level of fault when backed by a suitable protective device. If you want both functions in one unit, an RCBO such as the Hager ADM series is the alternative.

Why Type A sensing
A Type AC device only responds to sinusoidal AC residual currents. Type A extends that to pulsating DC residual currents, which arise from equipment containing rectifiers and electronic power supplies. Hager classifies the CDA440T as Type A, Class A.

Installation data

  • Terminals accept 1-25mm² rigid or 1-16mm² flexible conductors, top and bottom torqued to 2.8Nm.
  • Insulation voltage 500V with a 4kV impulse withstand rating.
  • Rated for installation up to 2000m altitude.
  • IP20 means it belongs inside an enclosed switchboard, not in an exposed position.
  • Optional Hager accessories include a shunt trip, undervoltage release, padlockable locking kit and heat dissipation insert.
  • Installation must be carried out by a licensed electrician to AS/NZS 3000.

Q: Does the Hager CDA440T protect against overload and short-circuit?
A: No. It is an RCCB, so it provides earth leakage protection only. Separate overcurrent protection is required, and its 6kA rating is a conditional short-circuit figure that assumes a suitable upstream device.

Q: What does Type A mean on the Hager CDA440T?
A: Type A residual current sensing detects both AC and pulsating DC earth fault currents, unlike Type AC devices which detect AC residual currents only.

Q: How wide is the Hager CDA440T in a switchboard?
A: It takes 4 DIN rail modules, measuring 70mm wide by 83mm high and 70mm deep.

(hagrcd440)

Specifications

Product Identity
Brand Hager
Model / Part Number CDA440T
Product Type Residual Current Circuit Breaker (RCCB)
Barcode (EAN) 3250611615507
Electrical Ratings
Number of Poles 4-pole (3P+N)
Rated Current (In) 40A
Rated Residual Operating Current (IΔn) 30mA
Residual Current Type Type A (AC and pulsating DC)
Rated Operational Voltage (Ue) 230/400V AC
Maximum Operating Voltage 440V AC
Rated Insulation Voltage (Ui) 500V
Rated Impulse Withstand Voltage (Uimp) 4,000V (4kV)
Frequency 50Hz
Conditional Short-Circuit Current (Inc) 6kA (per EN 61008-1, with suitable upstream MCB)
Rated Breaking Capacity (Idm) 1.50kA
Total Power Loss at Rated Current 6.50W
Temperature Performance (No Derating)
Rated Ambient Temperature Range -25°C to +70°C
Rated Current Across Full Range 40A (no derating at any temperature in range)
Physical Characteristics
Width 70mm (4 DIN modules)
Height 83mm
Depth 70mm
Mounting 35mm DIN rail (symmetrical / type O)
Neutral Position Right
Maximum Installation Altitude 2,000m
Terminals & Wiring
Top Terminals Screw type (aligned)
Bottom Terminals Biconnect (screw, aligned)
Max Conductor — Rigid 1–25mm²
Max Conductor — Flexible 1–16mm²
Terminal Tightening Torque (Top & Bottom) 2.8Nm
Endurance & Protection
Electrical Endurance 2,000 operations
Mechanical Endurance 4,000 operations
Ingress Protection (IP) IP20
Standards & Compliance
Standard EN 61008-1
Australian Installation Standard AS/NZS 3000
RoHS Compliance Yes
REACh Declaration Available from Hager
Warranty
Manufacturer Warranty 2 years (domestic and commercial)
SKU hagrcd440