Hager HMF399T Miniature Circuit Breaker MCB 125A 3 Pole C Curve 10kA 4.5 Module DIN Rail 415V

SKU: hagmcb312510k

Product Image Gallery

Product image thumbnail for SKU hagmcb312510k

Product Pricing

$451.82 (ex-GST)

$497.00 (inc-GST)

$497.00

$451.82

(inc-GST)
(ex-GST)

Stock and Availability

  • ⚫︎ Only 1 Left!

Hager HMF399T 125A three-pole miniature circuit breaker (MCB), C curve, 10kA breaking capacity. 4.5-module DIN rail design for high-current three-phase sub-main protection. Terminals to 70mm2, AS/NZS 60898 and 60947-2 compliant.

Electrotraders USPs

Fast Shipping, Trusted by Government, Easy Returns, Free Shipping over $200


Description

The 125A three-phase high-current MCB.

The Hager HMF399T is a 125A three-pole high-current miniature circuit breaker (MCB) with a C tripping curve and 10kA breaking capacity, the top of the three-phase HMF range, protecting sub-mains and heavy distribution from a 4.5-module DIN rail body.

Key Features

  • Rated current: 125A, three-phase (3P)
  • C tripping curve (5–10x In)
  • 10kA breaking capacity (Icn) to IEC 60898-1; Icu 10kA to IEC 60947-2
  • Rated voltage 415V AC, insulation voltage 500V
  • 4.5-module width (80mm) DIN rail mount
  • High-capacity terminals: rigid to 70mm², flexible to 50mm²
  • Rated impulse withstand voltage 6000V; IP20
  • Compliant with AS/NZS 60898.1 and AS/NZS IEC 60947-2

Order online today – fast dispatch on Hager circuit protection Australia-wide.

 

Why it Matters

Top of the three-phase high-current range.
The HMF399T is a 125A three-pole miniature circuit breaker, the largest in Hager's high-current HMF range, protecting all three phases of a circuit against overload and short circuit and tripping automatically when either occurs. At 125A across three poles it is built for the heaviest three-phase sub-mains and general distribution – feeding sub-boards, large machinery and high-demand three-phase loads – while still mounting on standard DIN rail rather than requiring a moulded-case breaker.

C curve and genuine cable capacity.
The C tripping characteristic trips on short circuit at 5 to 10 times rated current, the general-purpose curve for mixed resistive and inductive loads including motors and high inrush. Backed by a 10kA short-circuit breaking capacity to IEC 60898-1 (Icu 10kA to IEC 60947-2, with a 75% Ics service breaking capacity), its high-capacity terminals accept rigid conductors up to 70mm² and flexible up to 50mm² per pole at a 3.5 to 5.0Nm torque – matching the heavy cable a 125A three-phase feed runs.

Built for Australian switchboards.
At 4.5 modules (80mm) wide, 90mm high and 70mm deep, the HMF399T mounts on standard 35mm DIN rail with 360° mounting flexibility. It is compliant with AS/NZS 60898.1 and AS/NZS IEC 60947-2, rated IP20, and operates from -25°C to 70°C to suit main and sub-distribution boards across Australian conditions. At this rating heat is significant, so plan board ventilation and spacing and consider an LZ060 heat dissipation insert; MZN130 terminal cover, MZN175 locking kit and MZ auxiliaries are also available.

Q: Is the Hager HMF399T a three-phase breaker?
Yes. It is a 3-pole (3P) MCB that protects all three phases of a 415V circuit; it does not include a separate neutral pole, so a 3P+N model is needed where neutral switching is required.

Q: What cable can the HMF399T terminals take?
Rigid conductors up to 70mm² and flexible up to 50mm² per pole, tightened to between 3.5 and 5.0Nm – sized for a 125A three-phase sub-main.

Q: What does the 10kA rating mean on the HMF399T?
10kA is the rated short-circuit breaking capacity (Icn) to IEC 60898-1 – the maximum fault current the breaker can safely interrupt – with Icu 10kA and a 75% service breaking capacity (Ics) to IEC 60947-2.

(hagmcb312510k)

Specifications

Architecture
Type of pole 3P
Curve C
Voltage
Rated operational voltage Ue 400 - 415 V
Type voltage supply AC
Rated insulation voltage Ui 500 V
Rated impulse withstand voltage Uimp 6000 V
Frequency
Frequency 50 - 60 Hz
Electric current
Rated current 125 A
Rated short-circuit breaking capacity Icn under 230 V AC according to IEC 60898-1 10 kA
Rated ultimate short-circuit breaking capacity Icu under 230 V AC IEC 60947-2 10 kA
Rated ultimate short-circuit breaking capacity Icu under 400 V AC IEC 60947-2 10 kA
Installation, mounting
Nominal tightening torque 3,5 - 5,0 Nm
Type of top connection for modular devices Screw terminal
Type of bottom connection for modular devices Screw terminal
Nominal tightening torque down terminal 3,60 - 3,60 Nm
Nominal tightening torque top terminal 3,60 - 3,60 Nm
Main electrical attributes
Rated short-circuit breaking capacity Icn AC according to IEC 60898-1 10 kA
Power
Total power loss under IN 34,93 W
Endurance
Electric endurance in number of cycles 4000
Number of mechanical operations 20000
Connection
Cross-section of input and output with screws, for massive conductors 1 - 70 mm^2
Cross-section of input and output with screws, for flexible conductors 1 - 50 mm^2
Cross-section flexible conductor 50 mm^2
Cross-section rigid conductor 70 mm^2
Use conditions
Degree of pollution according to IEC 60664 / IEC 60947-2 3
Air humidity protection For all climates
Operating temperature -25 - 70 DegC
Capacity
Number of modules 4,50
Connectivity
Top connection alignment for modular devices Aligned terminal
Down connection alignment for modular devices Aligned terminal
Dimensions
Height 90 mm
Width 80 mm
Depth 70 mm
SKU hagmcb312510k
Manfacturer Part Number HMF399T
Barcode # 3250613231170
Brand Hager