Hager HMF399T Miniature Circuit Breaker MCB 125A 3 Pole C Curve 10kA 4.5 Module DIN Rail 415V
SKU: hagmcb312510k
Product Image Gallery
Product Pricing
$451.82 (ex-GST)
$497.00 (inc-GST)
$497.00
$451.82
Stock and Availability
- ⚫︎ Only 1 Left!
Hager HMF399T 125A three-pole miniature circuit breaker (MCB), C curve, 10kA breaking capacity. 4.5-module DIN rail design for high-current three-phase sub-main protection. Terminals to 70mm2, AS/NZS 60898 and 60947-2 compliant.
Electrotraders USPs
Description
The 125A three-phase high-current MCB.
The Hager HMF399T is a 125A three-pole high-current miniature circuit breaker (MCB) with a C tripping curve and 10kA breaking capacity, the top of the three-phase HMF range, protecting sub-mains and heavy distribution from a 4.5-module DIN rail body.
Key Features
- Rated current: 125A, three-phase (3P)
- C tripping curve (5–10x In)
- 10kA breaking capacity (Icn) to IEC 60898-1; Icu 10kA to IEC 60947-2
- Rated voltage 415V AC, insulation voltage 500V
- 4.5-module width (80mm) DIN rail mount
- High-capacity terminals: rigid to 70mm², flexible to 50mm²
- Rated impulse withstand voltage 6000V; IP20
- Compliant with AS/NZS 60898.1 and AS/NZS IEC 60947-2
Order online today – fast dispatch on Hager circuit protection Australia-wide.
Why it Matters
Top of the three-phase high-current range.
The HMF399T is a 125A three-pole miniature circuit breaker, the largest in Hager's high-current HMF range, protecting all three phases of a circuit against overload and short circuit and tripping automatically when either occurs. At 125A across three poles it is built for the heaviest three-phase sub-mains and general distribution – feeding sub-boards, large machinery and high-demand three-phase loads – while still mounting on standard DIN rail rather than requiring a moulded-case breaker.
C curve and genuine cable capacity.
The C tripping characteristic trips on short circuit at 5 to 10 times rated current, the general-purpose curve for mixed resistive and inductive loads including motors and high inrush. Backed by a 10kA short-circuit breaking capacity to IEC 60898-1 (Icu 10kA to IEC 60947-2, with a 75% Ics service breaking capacity), its high-capacity terminals accept rigid conductors up to 70mm² and flexible up to 50mm² per pole at a 3.5 to 5.0Nm torque – matching the heavy cable a 125A three-phase feed runs.
Built for Australian switchboards.
At 4.5 modules (80mm) wide, 90mm high and 70mm deep, the HMF399T mounts on standard 35mm DIN rail with 360° mounting flexibility. It is compliant with AS/NZS 60898.1 and AS/NZS IEC 60947-2, rated IP20, and operates from -25°C to 70°C to suit main and sub-distribution boards across Australian conditions. At this rating heat is significant, so plan board ventilation and spacing and consider an LZ060 heat dissipation insert; MZN130 terminal cover, MZN175 locking kit and MZ auxiliaries are also available.
Q: Is the Hager HMF399T a three-phase breaker?
Yes. It is a 3-pole (3P) MCB that protects all three phases of a 415V circuit; it does not include a separate neutral pole, so a 3P+N model is needed where neutral switching is required.
Q: What cable can the HMF399T terminals take?
Rigid conductors up to 70mm² and flexible up to 50mm² per pole, tightened to between 3.5 and 5.0Nm – sized for a 125A three-phase sub-main.
Q: What does the 10kA rating mean on the HMF399T?
10kA is the rated short-circuit breaking capacity (Icn) to IEC 60898-1 – the maximum fault current the breaker can safely interrupt – with Icu 10kA and a 75% service breaking capacity (Ics) to IEC 60947-2.
(hagmcb312510k)
Specifications
| Architecture | |
| Type of pole | 3P |
| Curve | C |
| Voltage | |
| Rated operational voltage Ue | 400 - 415 V |
| Type voltage supply | AC |
| Rated insulation voltage Ui | 500 V |
| Rated impulse withstand voltage Uimp | 6000 V |
| Frequency | |
| Frequency | 50 - 60 Hz |
| Electric current | |
| Rated current | 125 A |
| Rated short-circuit breaking capacity Icn under 230 V AC according to IEC 60898-1 | 10 kA |
| Rated ultimate short-circuit breaking capacity Icu under 230 V AC IEC 60947-2 | 10 kA |
| Rated ultimate short-circuit breaking capacity Icu under 400 V AC IEC 60947-2 | 10 kA |
| Installation, mounting | |
| Nominal tightening torque | 3,5 - 5,0 Nm |
| Type of top connection for modular devices | Screw terminal |
| Type of bottom connection for modular devices | Screw terminal |
| Nominal tightening torque down terminal | 3,60 - 3,60 Nm |
| Nominal tightening torque top terminal | 3,60 - 3,60 Nm |
| Main electrical attributes | |
| Rated short-circuit breaking capacity Icn AC according to IEC 60898-1 | 10 kA |
| Power | |
| Total power loss under IN | 34,93 W |
| Endurance | |
| Electric endurance in number of cycles | 4000 |
| Number of mechanical operations | 20000 |
| Connection | |
| Cross-section of input and output with screws, for massive conductors | 1 - 70 mm^2 |
| Cross-section of input and output with screws, for flexible conductors | 1 - 50 mm^2 |
| Cross-section flexible conductor | 50 mm^2 |
| Cross-section rigid conductor | 70 mm^2 |
| Use conditions | |
| Degree of pollution according to IEC 60664 / IEC 60947-2 | 3 |
| Air humidity protection | For all climates |
| Operating temperature | -25 - 70 DegC |
| Capacity | |
| Number of modules | 4,50 |
| Connectivity | |
| Top connection alignment for modular devices | Aligned terminal |
| Down connection alignment for modular devices | Aligned terminal |
| Dimensions | |
| Height | 90 mm |
| Width | 80 mm |
| Depth | 70 mm |
| SKU | hagmcb312510k |
| Manfacturer Part Number | HMF399T |
| Barcode # | 3250613231170 |
| Brand | Hager |