Hager ADC932T 32 Amps 1 Pole plus Neutral RCBO Safety Switch 6kA 30mA Type A C Curve 1 Module DIN Rail

SKU: hagrcb1326k

Product Image Gallery

Product image thumbnail for SKU hagrcb1326k
Product image thumbnail for SKU hagrcb1326k
Product image thumbnail for SKU hagrcb1326k
Product image thumbnail for SKU hagrcb1326k
Product image thumbnail for SKU hagrcb1326k

Product Pricing

$40.00 (ex-GST)

$44.00 (inc-GST)

$44.00

$40.00

(inc-GST)
(ex-GST)

Stock and Availability

  • ⚫︎ Only 4 Left!

Hager ADC932T 1P+N RCBO in a slim 17.7 mm DIN module. 32 A C curve, 30 mA Type A earth leakage sensing and 6 kA breaking capacity on 230-240 V circuits. Screw and BIconnect terminals, IP20, IEC 60898-1. In stock, ships in 24 hours across Australia.

Electrotraders USPs

Fast Shipping, Trusted by Government, Easy Returns, Free Shipping over $200


Description

32 A of 1P+N protection in one module.

The Hager ADC932T switches and protects both active and neutral on a 32 A final circuit, all in a single 17.7 mm module. It brings full 1P+N protection to larger power and general circuits without taking a second module of rail.

Key Features

  • Hager ADC932T RCBO, 1 pole plus neutral, 1 module (17.7 mm) wide
  • 32 A rated current, C curve tripping characteristic
  • 30 mA rated residual operating current, Type A
  • 6 kA rated short circuit breaking capacity (Icn, IEC 60898-1)
  • 230 - 240 V AC rated operational voltage, 50 - 60 Hz
  • Rated insulation voltage 440 V, impulse withstand 4 kV, energy limitation class 3
  • Screw terminal top, BIconnect bottom connection
  • Accepts 1 - 16 mm² solid or 1 - 10 mm² flexible conductors
  • Mounts on 35 mm DIN rail, IP20 rated
  • Wide operating range: -25 to 70 °C
  • 20,000 mechanical operations, 10,000 electrical cycles
  • Manufactured to IEC 60898-1, RoHS conform

Browse and buy - in stock and dispatched Australia-wide within 24 hours.

 

Neutral Switching, One Module

The ADC932T is a true 1P+N device: it switches and protects both the active and the neutral conductor. Traditionally that meant a two-module unit, but this slimline design does it in a single 17.7 mm module, height 85 mm and depth 70 mm, so it fits standard flush and surface switchboards while freeing rail space. The screw top terminal and BIconnect bottom terminal align it with the rest of a Hager modular assembly.

32 A for Larger Final Circuits

The 32 A rating suits higher-current final subcircuits: dedicated appliance feeds, larger power and general-purpose circuits, and sub-boards supplying power points and equipment where a 32 A load profile applies. The C curve tolerates the ordinary inrush of everyday equipment while tripping promptly on a genuine overload or short circuit, replacing a separate MCB and RCD in one device.

Type A Earth Leakage Sensing

As a Type A RCBO the ADC932T detects both sinusoidal AC earth leakage and pulsating DC earth leakage, unlike Type AC which detects only the AC component. With switch mode power supplies, inverters and variable speed drives now common on Australian final circuits, Type A is the practical baseline. It trips at a rated residual current of 30 mA.

Rated for Australian Conditions

Rated operational voltage is 230 - 240 V at 50 - 60 Hz, matching the Australian supply, with a maximum operating voltage of 264 V. Hager publishes a full derating curve: 32 A at 30 °C ambient, 30.70 A at 40 °C and 28 A at 60 °C, relevant where meter boxes and plant rooms run hot. The device is rated to 2000 m altitude.

Q: Is the Hager ADC932T single pole or double pole?
A: It is a 1 pole plus neutral (1P+N) device that switches and protects both the active and neutral conductors, in a single 17.7 mm module. The single-pole ADC232 range protects the active only.

Q: What is the difference between the ADC932T and the ADD932T?
A: Both are 32A 1P+N 6kA 30mA Type A RCBOs in one module. The ADC932T has a C curve for general circuits, while the ADD932T has a D curve for high-inrush loads such as motors and transformers.

Q: What can the 32 A ADC932T protect?
A: The 32 A C curve rating suits larger final circuits such as dedicated appliance feeds, power points and general equipment, providing combined overload, short circuit and 30 mA earth leakage protection with the neutral switched.

(hagrcb1326k)

Specifications

Architecture
Type of pole 1P+N
Curve C
Electric current
Rated current 32 A
Rated residual operating current Idn 30 mA
Rated current -25DegC 38,60 A
Rated current at -20DegC 38 A
Rated current -15DegC 37,40 A
Rated current -10DegC 36,80 A
Rated current -5DegC 36,20 A
Rated current at 0DegC 35,60 A
Rated current 5DegC 35 A
Rated current 10DegC 34,40 A
Rated current 15DegC 33,80 A
Rated current at 20DegC 33,20 A
Rated current 25DegC 32,60 A
Rated current 30DegC 32 A
Rated current 35DegC 31,30 A
Rated current at 40DegC 30,70 A
Rated current at 50DegC 29,30 A
Rated current 55DegC 28,60 A
Rated current 60DegC 28 A
Min./max. threshold value of the AC thermal operation 1,13 - 1,45 A
Safety
Residual current type A
Ingress Protection (IP) class IP20
Main electrical attributes
Rated short-circuit breaking capacity Icn AC according to IEC 60898-1 6 kA
Voltage
Rated insulation voltage Ui 440 V
Rated impulse withstand voltage Uimp 4000 V
Max. operating voltage 264 V
Rated operational voltage Ue 230 - 240 V
Overvoltage category according to IEC 60947-1 3
Power
Total power loss under IN 12,48 W
Frequency
Frequency 50 - 50 Hz
Use conditions
Max. Altitude 2000 m
Class of energy limitation I^2t 3
Operating temperature -25 - 70 DegC
Storage/transport temperature -25 - 80 DegC
Endurance
Electric endurance in number of cycles 10000
Number of mechanical operations 20000
Connection
Cross-section of input with screws, for flexible conductors 1 - 10 mm^2
Cross-section of input with screws, for massive conductors 1 - 16 mm^2
Cross-section of input and output with screws, for flexible conductors 1 - 10 mm^2
Cross-section of input and output with screws, for massive conductors 1 - 16 mm^2
Installation, mounting
Type of top connection for modular devices Screw terminal
Type of bottom connection for modular devices biconnect
Capacity
Number of modules 1
Dimensions
Height 85 mm
Width 17,70 mm
Depth 70 mm
Compatibility
Suitable for DIN Rail Yes
SKU hagrcb1326k
Manfacturer Part Number ADC932T
Barcode # 3250611033387
Brand Hager