Hager ADD216B RCBO Safety Switch 16A 1 Pole D Curve 10kA 30mA Type A 1 Module DIN Rail 230V

SKU: hagrcb11610kd

Product Image Gallery

Product image thumbnail for SKU hagrcb11610kd

Product Pricing

$200.81 (ex-GST)

$220.89 (inc-GST)

$220.89

$200.81

(inc-GST)
(ex-GST)

Stock and Availability

  • ⚫︎ Ships in 2-5 days

Hager ADD216B 16A single-pole RCBO safety switch combining MCB and RCD protection: D-curve overcurrent, 10kA breaking, 30mA Type A earth leakage. Compact 1-module DIN rail device. AS/NZS 61009 compliant.

Electrotraders USPs

Fast Shipping, Trusted by Government, Easy Returns, Free Shipping over $200


Description

Overcurrent and earth-leakage protection for high-inrush circuits.

The Hager ADD216B is a 16A single-pole RCBO (residual current breaker with overcurrent protection) combining D-curve overload and short-circuit protection with 30mA Type A earth-leakage protection in a compact 1-module DIN rail device.

Key Features

  • Rated current: 16A, single pole (1P)
  • D tripping curve (10–20x In) for high-inrush loads
  • 10kA breaking capacity (Icn) to IEC 60898-1
  • 30mA residual current, Type A (detects AC and pulsating DC)
  • Rated voltage 230–240V AC; insulation voltage 250V
  • Compact 1-module width (17.8mm) DIN rail mount
  • Accepts conductors 1–25mm² rigid, 1–16mm² flexible
  • IP20; rated impulse withstand 4000V; energy limiting class 3

Order online today – fast dispatch on Hager safety switches Australia-wide.

 

Why it Matters

Two protections in a single device.
The ADD216B is an RCBO – a residual current breaker with overcurrent protection – combining the functions of an MCB and an RCD in one module. It protects a circuit against overload and short circuit and, at the same time, disconnects on an earth-leakage fault of 30mA or more, guarding against electric shock. Combining both roles in one 1-module device saves board space compared with separate MCB and RCD components.

D curve and Type A leakage detection.
The D tripping characteristic trips on short circuit at 10 to 20 times rated current, suited to circuits with high inrush – transformers, motors and switch-mode supplies – that would nuisance-trip a standard C-curve device. Its Type A residual sensing detects both AC and pulsating DC earth-leakage currents, covering modern electronic loads, and its 10kA breaking capacity handles the fault levels found in commercial and industrial switchboards.

Built for Australian switchboards.
At one module (17.8mm) wide, 115mm high and 70mm deep, the ADD216B clips onto standard 35mm DIN rail. Terminals take rigid conductors up to 25mm², and it is rated IP20 with a 4kV impulse withstand and energy limiting class 3. It complies with AS/NZS 61009 for RCBOs and suits high-inrush final circuits requiring combined overcurrent and earth-leakage protection.

Q: What is an RCBO and how is the ADD216B different from an MCB?
An RCBO combines an MCB and an RCD in one device: it protects against overload and short circuit like an MCB, and also trips on earth leakage (30mA here) to guard against electric shock – protection a plain MCB does not provide.

Q: What does the D curve mean on the ADD216B?
The D curve trips on short circuit at 10 to 20 times the rated current, suited to high-inrush loads such as transformers and motors that would nuisance-trip a lower B or C curve.

Q: What is the difference between the ADD216B and the C-curve ADC216B?
Both are 16A 10kA RCBOs; the ADD216B has a D curve for high-inrush loads, while the ADC216B has a C curve for general-purpose circuits.

(hagrcb11610kd)

Specifications

Architecture
Type of pole1P
CurveD
Electric current
Rated current16 A
Rated residual operating current Idn30 mA
Rated current -25DegC20,81 A
Rated current at -20DegC20,38 A
Rated current -15DegC19,94 A
Rated current -10DegC19,50 A
Rated current -5DegC19,06 A
Rated current at 0DegC18,63 A
Rated current 5DegC18,19 A
Rated current 10DegC17,75 A
Rated current 15DegC17,31 A
Rated current at 20DegC16,88 A
Rated current 25DegC16,44 A
Rated current 30DegC16 A
Rated current 35DegC15,70 A
Rated current at 40DegC15,40 A
Rated current at 50DegC14,80 A
Rated current 55DegC14,50 A
Rated current 60DegC14,20 A
Min./max. threshold value of the AC thermal operation1,13 - 1,45 A
Safety
Residual current typeA
Ingress Protection (IP) classIP20
Main electrical attributes
Rated short-circuit breaking capacity Icn AC according to IEC 60898-110 kA
Voltage
Rated insulation voltage Ui250 V
Rated impulse withstand voltage Uimp4000 V
Rated operational voltage Ue230 - 240 V
Overvoltage category according to IEC 60947-13
Power
Total power loss under IN4,90 W
Frequency
Frequency50 - 60 Hz
Use conditions
Max. Altitude2000 m
Operating temperature-5 - 40 DegC
Storage/transport temperature-40 - 70 DegC
Endurance
Electric endurance in number of cycles2000
Number of mechanical operations10000
Connection
Cross-section of input with screws, for flexible conductors1 - 10 mm^2
Cross-section of input with screws, for massive conductors1 - 16 mm^2
Cross-section of input and output with screws, for flexible conductors1 - 16 mm^2
Cross-section of input and output with screws, for massive conductors1 - 25 mm^2
Installation, mounting
Type of top connection for modular devicesScrew terminal
Type of bottom connection for modular devicesbiconnect
Capacity
Number of modules1
Dimensions
Height115 mm
Width17,80 mm
Depth70 mm
Compatibility
Suitable for DIN RailYes
SKU hagrcb11610kd
Manfacturer Part Number ADD216B
Barcode # 3250611036029
Brand Hager