Hager ADC216B RCBO Safety Switch 16A 1 Pole C Curve 10kA 30mA Type A 1 Module DIN Rail 230V

SKU: hagrcb11610k

Product Image Gallery

Product image thumbnail for SKU hagrcb11610k

Product Pricing

$107.06 (ex-GST)

$117.77 (inc-GST)

$117.77

$107.06

(inc-GST)
(ex-GST)

Stock and Availability

  • ⚫︎ Ships in 24 hours

Hager ADC216B 16A single-pole RCBO safety switch combining MCB and RCD protection: C-curve overcurrent, 10kA breaking, 30mA Type A earth leakage. Compact 1-module DIN rail device. AS/NZS 61009 compliant.

Electrotraders USPs

Fast Shipping, Trusted by Government, Easy Returns, Free Shipping over $200


Description

Overcurrent and earth-leakage protection in one module.

The Hager ADC216B is a 16A single-pole RCBO (residual current breaker with overcurrent protection) combining C-curve overload and short-circuit protection with 30mA Type A earth-leakage protection in a compact 1-module DIN rail device.

Key Features

  • Rated current: 16A, single pole (1P)
  • C tripping curve (5–10x In)
  • 10kA breaking capacity (Icn) to IEC 60898-1
  • 30mA residual current, Type A (detects AC and pulsating DC)
  • Rated voltage 230–240V AC; insulation voltage 250V
  • Compact 1-module width (17.8mm) DIN rail mount
  • Accepts conductors 1–25mm² rigid, 1–16mm² flexible
  • IP20; rated impulse withstand 4000V; energy limiting class 3

Buy online now – fast dispatch on Hager safety switches Australia-wide.

 

Why it Matters

Two protections in a single device.
The ADC216B is an RCBO – a residual current breaker with overcurrent protection – combining the functions of an MCB and an RCD in one module. It protects a circuit against overload and short circuit and, at the same time, disconnects on an earth-leakage fault of 30mA or more, guarding against electric shock. Combining both roles in one 1-module device saves board space compared with separate MCB and RCD components.

C curve and Type A leakage detection.
The C tripping characteristic trips on short circuit at 5 to 10 times rated current, the general-purpose curve suited to the mixed resistive and moderately inductive loads on most power-point and appliance circuits – where a 16A rating is one of the most common sizes. Its Type A residual sensing detects both AC and pulsating DC earth-leakage currents, covering modern electronic loads, and its 10kA breaking capacity handles the fault levels found in commercial and industrial switchboards.

Built for Australian switchboards.
At one module (17.8mm) wide, 115mm high and 70mm deep, the ADC216B clips onto standard 35mm DIN rail. Terminals take rigid conductors up to 25mm², and it is rated IP20 with a 4kV impulse withstand and energy limiting class 3. It complies with AS/NZS 61009 for RCBOs and suits final circuits – power points, appliance and equipment feeds – requiring combined overcurrent and earth-leakage protection.

Q: What is an RCBO and how is the ADC216B different from an MCB?
An RCBO combines an MCB and an RCD in one device: it protects against overload and short circuit like an MCB, and also trips on earth leakage (30mA here) to guard against electric shock – protection a plain MCB does not provide.

Q: What is the difference between the ADC216B (10kA) and a 6kA RCBO?
10kA is the rated short-circuit breaking capacity, suited to higher-fault commercial and industrial boards; a 6kA RCBO such as the Hager ADC216T is used where fault levels are lower.

Q: What does Type A mean on the ADC216B?
Type A residual current detection responds to both AC and pulsating DC earth-leakage currents, covering electronic loads that a basic Type AC device may not detect.

(hagrcb11610k)

Specifications

Architecture
Type of pole1P
CurveC
Electric current
Rated current16 A
Rated residual operating current Idn30 mA
Rated current -25DegC20,81 A
Rated current at -20DegC20,38 A
Rated current -15DegC19,94 A
Rated current -10DegC19,50 A
Rated current -5DegC19,06 A
Rated current at 0DegC18,63 A
Rated current 5DegC18,19 A
Rated current 10DegC17,75 A
Rated current 15DegC17,31 A
Rated current at 20DegC16,88 A
Rated current 25DegC16,44 A
Rated current 30DegC16 A
Rated current 35DegC15,70 A
Rated current at 40DegC15,40 A
Rated current at 50DegC14,80 A
Rated current 55DegC14,50 A
Rated current 60DegC14,20 A
Min./max. threshold value of the AC thermal operation1,13 - 1,45 A
Safety
Residual current typeA
Ingress Protection (IP) classIP20
Main electrical attributes
Rated short-circuit breaking capacity Icn AC according to IEC 60898-110 kA
Voltage
Rated insulation voltage Ui250 V
Rated impulse withstand voltage Uimp4000 V
Rated operational voltage Ue230 - 240 V
Overvoltage category according to IEC 60947-13
Power
Total power loss under IN4,90 W
Frequency
Frequency50 - 60 Hz
Use conditions
Max. Altitude2000 m
Class of energy limitation I^2t3
Operating temperature-5 - 40 DegC
Storage/transport temperature-40 - 70 DegC
Endurance
Electric endurance in number of cycles2000
Number of mechanical operations10000
Connection
Cross-section of input with screws, for flexible conductors1 - 10 mm^2
Cross-section of input with screws, for massive conductors1 - 16 mm^2
Cross-section of input and output with screws, for flexible conductors1 - 16 mm^2
Cross-section of input and output with screws, for massive conductors1 - 25 mm^2
Installation, mounting
Type of top connection for modular devicesScrew terminal
Type of bottom connection for modular devicesbiconnect
Capacity
Number of modules1
Dimensions
Height115 mm
Width17,80 mm
Depth70 mm
Compatibility
Suitable for DIN RailYes
SKU hagrcb11610k
Manfacturer Part Number ADC216B
Barcode # 3250611035527
Brand Hager