Red Smoke RHA240SL 240V Heat Alarm Rechargeable Lithium Backup
SKU: rerha240
Product Image Gallery
Product Pricing
$68.84 (ex-GST)
$75.72 (inc-GST)
$75.72
$68.84
Stock and Availability
- ⚫︎ Ships in 2-5 days
240V mains heat alarm with 3V rechargeable 10 year backup. Thermistor activates at 55-59C, ideal for kitchens and garages. 85dB alarm, hardwired interconnect up to 40 devices. AS1603.3 certified.
Electrotraders USPs
Description
240V mains heat alarm with rechargeable backup.
The Red Smoke RHA240SL is a 240V AC mains-powered heat alarm with a 3V rechargeable lithium backup battery rated for 10 years, so it continues to operate during a power failure. It uses a thermistor that activates at 55–59°C, making it suitable for kitchens, garages and other areas where smoke alarms are prone to nuisance alarms. It sounds an 85dB local alarm, can be hardwired and interconnected with up to 40 devices, and is certified to the Australian Standard AS1603.3:2018.
Key Features
- 240V AC mains powered with 3V rechargeable lithium backup
- 10 year backup battery life
- Thermistor heat sensor – activates at 55–59°C
- Fast response time of approximately 1 second
- Hardwired interconnect – up to 40 devices
- Interconnect operating distance up to 150m in free field
- 85dB minimum local alarm at 3 metres
- Hush function and test button
- LED indicators – green for power, red for warning and low battery
- Certified to AS1603.3:2018, CSIRO approved
- Indoor use, white finish
Shop now for fast dispatch across Australia.
Heat Detection for Nuisance-Prone Areas
Unlike a smoke alarm, the RHA240SL responds to heat rather than smoke, using a thermistor that activates when the temperature reaches 55–59°C. This makes it the right choice for kitchens, garages, laundries and similar spaces where cooking fumes, dust or steam would cause a smoke alarm to false-trigger. Its response time is approximately 1 second once the activation temperature is reached.
Mains Power with Rechargeable Backup
Running on 220–240V AC mains, the alarm maintains continuous monitoring, while its 3V rechargeable lithium battery provides backup during a mains failure. The backup is rated for 10 years, with a low-battery signal at 2.7V and an interconnect voltage of 9V.
Interconnect up to 40 Devices
The RHA240SL can be hardwired and interconnected with up to 40 compatible devices over a distance of up to 150m in free field. It can be interconnected with Red Smoke R240 and R240RC smoke alarms, and with RF-capable units when fitted with the appropriate RF module, so heat and smoke detection can be combined in a single interconnected system.
Q: How is a heat alarm different from a smoke alarm?
A: A heat alarm responds to temperature rather than smoke, activating at 55–59°C. This makes it suitable for kitchens, garages and other areas where a smoke alarm would be prone to nuisance alarms.
Q: Can it be interconnected with smoke alarms?
A: Yes. It can be hardwired and interconnected with up to 40 devices, including Red Smoke R240 and R240RC smoke alarms, so heat and smoke detection work together.
Q: Is it certified for use in Australia?
A: Yes. It is certified to the Australian Standard AS1603.3:2018 and is CSIRO approved.
Warranty

Red Smoke Alarms – Manufacturer Warranty
Red Smoke Alarms are built to last and backed by a 10-year warranty for both residential and commercial use. Faults are rare, but if something does go wrong, support is just a call or click away.
To submit a warranty claim, you can either:
-
Call Red Smoke Alarms on 1300 316 552, or
-
Submit a claim online at: redsmokealarms.com.au/warranty
Red Smoke Alarms are supported by a national network of service agents ready to assist in the unlikely event of a fault.
Note: For the fastest resolution, contact Red Smoke Alarms directly. Warranty claims and repairs are handled exclusively by their team—not through Electrotraders.
(rerha240)
Specifications
| General Specifications | |
| SKU | rerha240-in |
| Model | RHA240SL |
| Product Type | Heat alarm (detector) |
| Device Application | Activates at 55–59°C |
| Sensor Type | Thermistor sensor |
| Colour | White |
| Power | |
| Rated Supply Voltage | 220–240V AC |
| Power Supply | AC mains |
| Backup Type | 3V lithium battery |
| Battery Life | 10 years |
| Output Voltage Limits | Interconnected 9V / Low battery 2.7V |
| Detection & Alarm | |
| Detection Type | Thermistor, activates at 55–59°C |
| Response Time | Approx. 1 second |
| Function | Heat detection, local alarm, hush function, test button |
| Noise Level | 85dB at 3m minimum |
| Time Delay Range | 10 min (hush), 10 hr (silence) |
| Interconnect | |
| Control Type | Hardwired interconnected |
| Number of Devices | Up to 40 |
| Operating Distance | 150m in free field |
| Compatible Devices | R240, R240RC; RF units with RFMOD |
| Indicators | |
| Power (On) Status | Green LED |
| Warning / Low Battery | Red LED |
| Physical & Environmental | |
| Alarm Diameter | 123mm |
| Protrusion from Ceiling | 66mm |
| Installation | Indoor, surface, wall or ceiling mount by screws |
| Operating Temperature | -10°C to 40°C |
| Relative Humidity | 5–95% |
| Compliance | |
| Standards | AS1603.3:2018 |
| Certification | CSIRO |
| SKU | rerha240 |
| Manfacturer Part Number | RHA240SL |
| Brand | Red Smoke |
| Assembled Length | 0.123m |
| Assembled Height | 0.066m |
| Assembled Width | 0.123m |
Shipping Calculator