Red Smoke RFMDUAL Flush Mount 240V Photoelectric Smoke Alarm Dual Power
SKU: rerpfmdual
Product Image Gallery
Product Pricing
$59.00 (ex-GST)
$64.90 (inc-GST)
$64.90
$59.00
Bulk Carton size
10Stock and Availability
- ⚫︎ 12 In Stock
Approved for QLD Government Housing Installation
Electrotraders USPs
Description
Dual-power protection, flush to the ceiling.
The Red Smoke RFMDUAL is a flush-mount photoelectric smoke alarm with dual power: run it on 240V mains with a sealed 10-year lithium battery backup, or as a standalone 10-year lithium battery alarm. Recessed into a 90mm cut-out, it sits level with the ceiling for a discreet, architectural finish.
Key Features
- Flush-mount design, recesses into a 90mm ceiling cut-out
- Dual power: 240V mains with sealed 10-year lithium backup, or battery-only operation
- Type A photoelectric sensor – detects smouldering and open fires
- Hardwired interconnect, or wireless with the optional RFMOD module (up to 40 combined)
- Sealed 10-year lithium battery (CR123A / CR17335) – no battery changes
- 85 dB alarm at 3m (ISO 8201 pattern), approximately 8-second response
- Test and hush button, with LED status indication
- Certified to AS 3786:2014+A1:2015+A2:2018 (CSIRO ActivFire, cert. afp-3837)
- Approved for QLD Government Housing installation
Add one to your cart for fast dispatch nationwide.
Discreet Flush-Mount Finish
Unlike a surface alarm that sits proud of the ceiling, the RFMDUAL recesses into a 90mm cut-out so the alarm finishes level with the ceiling line. The alarm body is around 110mm in diameter and extends roughly 62mm into the ceiling cavity, so check you have the clearance above the plasterboard before cutting. The result is a clean, low-profile look that suits feature ceilings and quality fitouts. The unit ships in a plastic dust cover – keep it covered through construction and remove it at commissioning.
Dual Power, Flexible Install
Wire the RFMDUAL to 240V mains for continuous operation, with the sealed lithium battery providing standby if mains power is lost. Where there is no mains, it runs on the 10-year battery alone (note there is no separate standby source in battery-only mode). The photoelectric sensor responds well to slow, smouldering fires, and a hush function quietens nuisance alarms for around 10 minutes.
Interconnect a Whole Home
Hardwire the alarms together so that when one detects smoke, they all sound. Where running interconnect cable is not practical, the optional RFMOD wireless module links alarms by radio at 433.92 MHz. Up to 40 alarms can be interconnected in total across wired and wireless. Note the interconnect terminal is for hardwiring directly to other smoke and heat alarms; do not combine RF modules and hardwired interconnect on the same unit.
Q: How is the Red Smoke RFMDUAL powered?
A: By 240V mains with a sealed 10-year lithium battery as standby, or on the lithium battery alone where there is no mains. The battery is not replaceable, so the whole alarm is replaced at end of life.
Q: What size cut-out does the RFMDUAL need?
A: A 90mm ceiling cut-out. The alarm body is about 110mm in diameter and recesses roughly 62mm into the cavity, finishing level with the ceiling.
Q: Is the Red Smoke RFMDUAL compliant for Queensland homes?
A: It is a photoelectric, interconnectable alarm certified to AS 3786:2014 and approved for QLD Government Housing installation. Always confirm placement and interconnection meet current requirements.
Warranty

Red Smoke Alarms – Manufacturer Warranty
Red Smoke Alarms are built to last and backed by a 10-year warranty for both residential and commercial use. Faults are rare, but if something does go wrong, support is just a call or click away.
To submit a warranty claim, you can either:
-
Call Red Smoke Alarms on 1300 316 552, or
-
Submit a claim online at: redsmokealarms.com.au/warranty
Red Smoke Alarms are supported by a national network of service agents ready to assist in the unlikely event of a fault.
Note: For the fastest resolution, contact Red Smoke Alarms directly. Warranty claims and repairs are handled exclusively by their team—not through Electrotraders.
(rerpfmdual)
Specifications
| Product Specifications | |
| Device Application | Early detection of smouldering fires and open fires |
| Sensor Type | Type A photoelectric sensor |
| Mounting Style | Flush mount (recessed) |
| Colour | White |
| Quantity | 1 |
| Packaging Type | Carton |
| Electrical Specifications | |
| Power Supply | 240V mains or 3V lithium battery |
| Rated Supply Voltage | 220–240Vac (230Vac nominal) |
| Backup Type | 3V lithium battery (standby when on AC mains; no standby source in battery-only mode) |
| Battery | CR123A / CR17335 3V lithium, sealed (non-replaceable, non-rechargeable) |
| Battery Life | 10 years |
| Functional Features | |
| Detection Type | Smoke |
| Function | Hush function |
| Control Type | Button for test / hush function |
| Local Alarm | Yes |
| Response Time | Approx. 8 seconds |
| Noise Level | 85 dB at 3m minimum (ISO 8201 alarm pattern) |
| Time Delay Range | 10 min: hush |
| Interconnection Capabilities | |
| Interconnect Method | Hardwired, or wireless with optional RFMOD module |
| Maximum Interconnected (Combined) | 40 alarms total (wired and wireless combined) |
| Transmission Frequency (with RFMOD) | Radio frequency 433.92 MHz |
| Operating Distance (Hard Wired) | 150m in free field |
| Installation & Dimensions | |
| Ceiling Cut-Out | 90 mm diameter |
| Alarm Diameter | 110 mm |
| Alarm Depth (into cavity) | 62 mm |
| Fixing Method | Flush mount, clamp screws onto ceiling |
| Environmental Conditions | |
| Ambient Air Temperature | 0–45°C |
| Relative Humidity | 5–95% |
| Certifications | |
| Product Certifications | CSIRO ActivFire (cert. afp-3837) |
| Standards | AS 3786:2014+A1:2015+A2:2018 |
| SKU | rerpfmdual |
| Brand | Red Smoke |
Shipping Calculator