Hager MSN320 Miniature Circuit Breaker MCB 20A 3 Pole C Curve 6kA 3 Module DIN Rail 415V
SKU: hagmcb3206k
Product Image Gallery
Product Pricing
$42.00 (ex-GST)
$46.20 (inc-GST)
$46.20
$42.00
Stock and Availability
- ⚫︎ Only 1 Left!
Hager MSN320 20A three-pole miniature circuit breaker (MCB) with C tripping curve and 6kA breaking capacity. 3-module DIN rail design protects three-phase circuits against overload and short circuit. AS/NZS 60898 compliant.
Electrotraders USPs
Description
Three-phase 20A protection.
The Hager MSN320 is a 20A three-pole miniature circuit breaker (MCB) with a C tripping curve and 6kA breaking capacity, protecting three-phase residential and light commercial circuits against overload and short circuit from a 3-module DIN rail body.
Key Features
- Rated current: 20A, three-phase (3P)
- C tripping curve (5–10x In)
- 6kA breaking capacity (Icn) to IEC 60898-1
- Rated voltage 415V AC, insulation voltage 500V
- 3-module width (52.5mm) DIN rail mount
- Accepts conductors 1–35mm² rigid, 1–25mm² flexible
- Energy limiting class 3; IP20; 360° mounting
- Compliant with AS/NZS 60898.1
Shop now – fast dispatch on Hager circuit protection Australia-wide.
Why it Matters
Protects all three phases together.
The MSN320 is a 20A three-pole miniature circuit breaker, protecting a three-phase circuit against both overload and short circuit and tripping automatically when either occurs. Its three linked poles switch and protect all three phases as one, a common choice for larger three-phase power sub-circuits, motors and distribution feeds in homes and light commercial boards, with a 6kA breaking capacity for the fault levels found in those switchboards.
C curve for motor and mixed loads.
The C tripping characteristic trips on short circuit at 5 to 10 times rated current, the general-purpose curve suited to mixed resistive and inductive loads including the inrush of three-phase motors. Backed by a 6kA short-circuit breaking capacity to IEC 60898-1 and energy limiting class 3, the MSN320 limits let-through energy during a fault to help protect downstream cabling.
Built for Australian switchboards.
At three modules (52.5mm) wide, 83mm high and 70mm deep, the MSN320 clips onto standard 35mm DIN rail with 360° mounting flexibility, and its terminals take rigid conductors up to 35mm² at 2.8Nm. It is compliant with AS/NZS 60898.1, rated IP20, and operates from -25°C to 70°C to suit distribution boards and homes across Australian conditions. Hager auxiliaries including the MZ201 auxiliary contact, MZ202 alarm contact and MZ203/MZ204 shunt trips are available.
Q: Is the Hager MSN320 a three-phase breaker?
Yes. It is a 3-pole (3P) MCB that switches and protects all three phases of a 415V circuit together; it does not include a separate neutral pole.
Q: What does the C curve mean on the MSN320?
The C curve trips on short circuit at 5 to 10 times the rated current, making it the general-purpose characteristic for mixed resistive and inductive loads including motors.
Q: What is the difference between the MSN320 (6kA) and a 10kA MCB?
6kA is the rated short-circuit breaking capacity, suited to residential and light commercial boards; a 10kA breaker such as Hager's NT range is specified where fault levels are higher, typically in commercial and industrial installations.
(hagmcb3206k)
Specifications
| Electric current | |
| Rated current | 20 A |
| Rated current -15DegC | 24,4 A |
| Rated current -10DegC | 24 A |
| Rated current -5DegC | 23,5 A |
| Rated current at 0DegC | 23,1 A |
| Rated current 5DegC | 22,6 A |
| Rated current 10DegC | 22,1 A |
| Rated current 15DegC | 21,6 A |
| Rated current at 20DegC | 21,1 A |
| Rated current 25DegC | 20,5 A |
| Rated current 30DegC | 20 A |
| Rated current 35DegC | 19,4 A |
| Rated current at 40DegC | 18,7 A |
| Rated current at 45DegC | 18 A |
| Rated current at 50DegC | 17,3 A |
| Rated current 55DegC | 16,6 A |
| Rated current 60DegC | 15,8 A |
| Rated current 65DegC | 15 A |
| Rated current 70DegC | 14,1 A |
| Architecture | |
| Type of pole | 3P |
| Curve | C |
| Capacity | |
| Number of modules | 3 |
| Installation, mounting | |
| Nominal tightening torque top terminal | 2,80 - 2,80 Nm |
| Nominal tightening torque down terminal | 2,80 - 2,80 Nm |
| Nominal tightening torque | 2,80 - 2,80 Nm |
| Type of bottom connection for modular devices | biconnect |
| Type of top connection for modular devices | Screw terminal |
| 360?ø mounting position possible | Yes |
| Main electrical attributes | |
| Rated short-circuit breaking capacity Icn AC according to IEC 60898-1 | 6 kA |
| Voltage | |
| Rated operational voltage Ue | 415 - 415 V |
| Type voltage supply | AC |
| Rated insulation voltage Ui | 500 V |
| Rated impulse withstand voltage Uimp | 4000 V |
| Frequency | |
| Frequency | 50 - 60 Hz |
| Connection | |
| Cross-section of input and output with screws, for massive conductors | 1 - 35 mm^2 |
| Cross-section of input and output with screws, for flexible conductors | 1 - 25 mm^2 |
| Cross-section of input with screws, for flexible conductors | 1 - 25 mm^2 |
| Cross-section of input with screws, for massive conductors | 1 - 35 mm^2 |
| Cross-section flexible conductor | 1 - 25 mm^2 |
| Cross-section rigid conductor | 1 - 35 mm^2 |
| Safety | |
| Ingress Protection (IP) class | IP20 |
| Use conditions | |
| Degree of pollution according to IEC 60664 / IEC 60947-2 | 2 |
| Class of energy limitation I^2t | 3 |
| Air humidity protection | For all climates |
| Operating temperature | -25 - 70 DegC |
| Power | |
| Total power loss under IN | 8,9 W |
| Connectivity | |
| Type of connection | Screw terminal |
| Top connection alignment for modular devices | Aligned terminal |
| Down connection alignment for modular devices | Aligned terminal |
| Dimensions | |
| Height | 83 mm |
| Width | 52,50 mm |
| Depth | 70 mm |
| SKU | hagmcb3206k |
| Manfacturer Part Number | MSN320 |
| Barcode # | 3250614324031 |
| Brand | Hager |
Shipping Calculator