Hager MSN163 Miniature Circuit Breaker MCB 63A 1 Pole C Curve 6kA 1 Module DIN Rail 240-415V

SKU: hagmcb1636k

Product Image Gallery

Product image thumbnail for SKU hagmcb1636k

Product Pricing

Was $9.01
Now
$7.00 (ex-GST)
$7.70 (inc-GST)

$7.70

Now

$7.00

(inc-GST)
(ex-GST)

Stock and Availability

  • ⚫︎ Only 2 Left!

Hager MSN163 63A single-pole miniature circuit breaker (MCB) with C tripping curve and 6kA breaking capacity. Compact 1-module DIN rail design protects circuits against overload and short circuit. AS/NZS 60898 compliant.

Electrotraders USPs

Fast Shipping, Trusted by Government, Easy Returns, Free Shipping over $200


Description

Top of the range at 63A.

The Hager MSN163 is a 63A single-pole miniature circuit breaker (MCB) with a C tripping curve and 6kA breaking capacity, the top of the MSN range, protecting residential and light commercial circuits against overload and short circuit from a 1-module DIN rail body.

Key Features

  • Rated current: 63A, single pole (1P)
  • C tripping curve (5–10x In)
  • 6kA breaking capacity (Icn) to IEC 60898-1
  • Rated voltage 240–415V AC, insulation voltage 500V
  • Compact 1-module width (17.5mm) DIN rail mount
  • Accepts conductors 1–35mm² rigid, 1–25mm² flexible
  • Energy limiting class 3; IP20; 360° mounting
  • Compliant with AS/NZS 60898.1

Order online today – fast dispatch on Hager circuit protection Australia-wide.

 

Why it Matters

The highest-current MSN breaker.
The MSN163 is a 63A miniature circuit breaker, the top of Hager's 1-pole MSN range, protecting a circuit against both overload and short circuit and tripping automatically when either occurs. A 63A rating is the choice for main-switch and heavy sub-main duty in homes and light commercial boards – sub-boards, large appliances and high-demand feeds – and its 6kA breaking capacity suits the fault levels found in those switchboards.

C curve for high-inrush loads.
The C tripping characteristic trips on short circuit at 5 to 10 times rated current, the general-purpose curve suited to mixed resistive and moderately inductive loads and high-inrush circuits. Backed by a 6kA short-circuit breaking capacity to IEC 60898-1 and energy limiting class 3, the MSN163 limits let-through energy during a fault to help protect downstream cabling.

Built for Australian switchboards.
At one module (17.5mm) wide, 83mm high and 70mm deep, the MSN163 clips onto standard 35mm DIN rail with 360° mounting flexibility, and its terminals take rigid conductors up to 35mm² at 2.8Nm. It is compliant with AS/NZS 60898.1, rated IP20, and operates from -25°C to 70°C to suit meter boxes, distribution boards and homes across Australian conditions. With 7.4W dissipation at full load, allow for heat in tightly packed boards. Hager auxiliaries including the MZ201 auxiliary contact, MZ202 alarm contact and MZ203/MZ204 shunt trips are available.

Q: What is the Hager MSN163 used for?
It is a 63A single-pole MCB, the highest rating in the 1-pole MSN range, for protecting main-switch and heavy sub-main circuits against overload and short circuit in residential and light commercial boards.

Q: What does the C curve mean on the MSN163?
The C curve trips on short circuit at 5 to 10 times the rated current, making it the general-purpose characteristic for mixed resistive and moderately inductive loads.

Q: What is the difference between the MSN163 (6kA) and a 10kA MCB?
6kA is the rated short-circuit breaking capacity, suited to residential and light commercial boards; a 10kA breaker such as Hager's NT range is specified where fault levels are higher, typically in commercial and industrial installations.

(hagmcb1636k)

Specifications

Electric current
Rated current 63 A
Rated short-circuit breaking capacity Icn under 230 V AC according to IEC 60898-1 6 kA
Rated current -15DegC 79,87 A
Rated current -10DegC 78,28 A
Rated current -5DegC 76,76 A
Rated current at 0DegC 75,21 A
Rated current 5DegC 73,66 A
Rated current 10DegC 72,10 A
Rated current 15DegC 70,55 A
Rated current at 20DegC 68,99 A
Rated current 25DegC 67,44 A
Rated current 30DegC 65,89 A
Rated current 35DegC 64,33 A
Rated current at 40DegC 63 A
Rated current at 45DegC 61,22 A
Rated current at 50DegC 59,48 A
Rated current 55DegC 58,12 A
Rated current 60DegC 56,56 A
Rated current 65DegC 55,01 A
Rated current 70DegC 53,45 A
Architecture
Type of pole 1P
Curve C
Capacity
Number of modules 1
Installation, mounting
Nominal tightening torque top terminal 2,80 - 2,80 Nm
Nominal tightening torque down terminal 2,80 - 2,80 Nm
Nominal tightening torque 2,80 - 2,80 Nm
Type of bottom connection for modular devices biconnect
Type of top connection for modular devices Screw terminal
360?ø mounting position possible Yes
Main electrical attributes
Rated short-circuit breaking capacity Icn AC according to IEC 60898-1 6 kA
Voltage
Rated operational voltage Ue 240 - 415 V
Type voltage supply AC
Rated insulation voltage Ui 500 V
Rated impulse withstand voltage Uimp 4000 V
Frequency
Frequency 50 - 60 Hz
Connection
Cross-section of input and output with screws, for massive conductors 1 - 35 mm^2
Cross-section of input and output with screws, for flexible conductors 1 - 25 mm^2
Cross-section of input with screws, for flexible conductors 1 - 25 mm^2
Cross-section of input with screws, for massive conductors 1 - 35 mm^2
Cross-section flexible conductor 1 - 25 mm^2
Cross-section rigid conductor 1 - 35 mm^2
Safety
Ingress Protection (IP) class IP20
Use conditions
Degree of pollution according to IEC 60664 / IEC 60947-2 2
Class of energy limitation I^2t 3
Air humidity protection For all climates
Operating temperature -25 - 70 DegC
Power
Total power loss under IN 7,4 W
Connectivity
Type of connection Screw terminal
Top connection alignment for modular devices Aligned terminal
Down connection alignment for modular devices Aligned terminal
Dimensions
Height 83 mm
Width 17,50 mm
Depth 70 mm
SKU hagmcb1636k
Manfacturer Part Number MSN163
Barcode # 3250613810146
Brand Hager

Shipping Calculator


Others Also Bought