PPO10T Transco Portable Power Outlet IP53 4 Way 10 Amp Outlet MCB/RCD WHS Approved
SKU: trappo10
Product Image Gallery
Product Pricing
$75.00 (ex-GST)
$82.50 (inc-GST)
$82.50
$75.00
Stock and Availability
- ⚫︎ Only 4 Left!
Transco Portable Power Board IP53 4 Way 10 Amp Outlet MCB/RCD WHS Approved
Electrotraders USPs
Description
4 Way. RCBO Protected. IP53 Weatherproof. Class H Approved. Built for the Site.
The Transco PPO10T is an IP53 rated 4 way portable power outlet with built-in 10A RCBO protection — the Australian Industrial Class H approved safety power board designed specifically for construction sites, demolition sites, and industrial environments where electrical safety and weatherproof performance are mandatory requirements. Four recessed outlets, neon indicators, patented inlet membrane protection, neoprene rocker seal, gasket sealed housing, and a heavy-duty 1.8m power cord that winds fully onto the unit. Orange polycarbonate construction. Sold individually.
- Transco — IP53 4 way portable power outlet with built-in RCBO
- Orange impact-resistant polycarbonate construction
- Rated 10A at 240V AC — 2400W maximum load
- Built-in RCBO — current leakage, short circuit, and overload protection
- 4 x recessed double pole outlets — recessed for added protection
- Patented inlet membrane protection on each outlet
- Neon power indicator on each outlet
- Neoprene boot protected rocker switch — weatherproof and insulated
- Gasket sealed housing
- Clear cover over RCD/MCB for protection and easy access
- IP53 ingress protection — NATA lab tested
- Australian Industrial Class H approved
- Heavy duty 1.8m power cord — fully winds onto unit
- Large sturdy base with anchor holes for stability
- Flat earth pin configuration
- Single phase AC, 240V, 50Hz
- Dimensions: W174 mm x D150 mm x H180 mm
- Compliant with AS/NZS 3190, AS/NZS 3012
- PSOA suitable for building and demolition sites
- Also available in 15A (PPO1530 — 3600W maximum)
Order online now for fast dispatch Australia-wide.
Why the PPO10T Is the Standard Portable Power Outlet for Australian Construction Sites
WHS legislation in Australia mandates RCD protection for all portable electrical equipment used on construction and demolition sites. The PPO10T meets that requirement with a built-in 10A RCBO that provides simultaneous protection against current leakage (residual current), short circuit, and overload — three independent protection functions in a single device. The Class H industrial approval and compliance with AS/NZS 3012 (Electrical Installations — Construction and Demolition Sites) confirm the PPO10T is specifically assessed and approved for the site environment, not just rated for general purpose use.
The IP53 weatherproof rating — NATA lab tested — provides dust protection and resistance to water spray, covering the typical outdoor site exposure conditions of construction and demolition environments. The patented inlet membrane technology on each outlet maintains weatherproofing at the socket entry point, the neoprene rocker seal protects the switch, and the gasket sealed housing prevents moisture ingress at the enclosure joints — three layers of weatherproof protection working together. The neon indicators on each outlet give an instant visual status check for power on/off, and the clear cover over the RCBO allows the protection status to be verified without opening the unit.
The recessed outlet positions, large base with anchor holes for stability, and heavy-duty 1.8m cord that winds fully onto the unit are all features developed in direct response to real site use — the PPO10T is not an office power board with an IP rating; it is a purpose-designed site power distribution unit. Also available in 15A (PPO1530) for higher-draw site equipment and tools that exceed the 10A rating.
Q: What does RCBO protection mean in the Transco PPO10T?
A: The built-in RCBO (Residual Current Circuit Breaker with Overcurrent protection) in the PPO10T provides three simultaneous protection functions — residual current (earth leakage) protection that trips when current leaks to earth (protecting the user against electrocution), short circuit protection that trips in a fault condition, and overload protection that trips when the connected load exceeds the 10A rating. This combined protection is what makes the PPO10T compliant with AS/NZS 3190 and suitable for construction site use under WHS requirements.
Q: What does Australian Industrial Class H approval mean for the PPO10T?
A: Class H is the Australian standard for industrial electrical equipment approved for use on construction and demolition sites. It indicates the PPO10T has been tested and approved as suitable for the demanding conditions of building and demolition sites — including exposure to dust, moisture, mechanical impact, and the electrical fault environments typical of site use. The Class H approval is required for RCD-protected portable power outlets used on construction sites under AS/NZS 3012.
Q: What is the difference between the PPO10T and the PPO1530?
A: The PPO10T is rated at 10A (2400W maximum load) and the PPO1530 is rated at 15A (3600W maximum load). Both are IP53, Class H approved, 4 way portable power outlets with built-in RCBO protection and the same patented membrane, neoprene seal, and gasket sealed housing features. Choose the PPO1530 where site tools or equipment draw sustained current beyond the 10A rating.
(trappo10)
Specifications
| Product | |
| Brand | Transco |
| Model / Product Code | PPO10T |
| Description | IP53 4 Way Portable Power Outlet with Built-in RCBO 10A — Class H Approved |
| Colour | Orange |
| Electrical | |
| Current Rating | 10A |
| Voltage | 240V |
| Maximum Load | 2400W |
| Current Type | AC |
| Phase | Single |
| Number of Outlets | 4 |
| Earth Pin | Flat |
| Protection | |
| Built-in Protection | RCBO — residual current, short circuit, and overload |
| Outlet Protection | Patented inlet membrane technology |
| Switch Protection | Neoprene boot protected rocker switch |
| Housing Seal | Gasket sealed |
| RCBO Cover | Clear cover — protected and accessible |
| Ingress Protection | |
| IP Rating | IP53 — NATA lab tested |
| Dust Protection | Dust protected (IP5x) |
| Water Protection | Protected against water spray (IPx3) |
| Indicators | |
| Neon Indicators | Yes — one per outlet |
| Physical | |
| Width | 174 mm |
| Depth | 150 mm |
| Height | 180 mm |
| Lead Length | 1.8 metres — winds fully onto unit |
| Base | Large sturdy base with anchor holes |
| Materials & Construction | |
| Material | Impact-resistant polycarbonate |
| Variants Available | |
| PPO10T | 10A — 2400W maximum (this product) |
| PPO1530 | 15A — 3600W maximum |
| Compliance & Standards | |
| Standards | AS/NZS 3190, AS/NZS 3012 |
| Industrial Approval | Australian Industrial Class H |
| Site Suitability | PSOA — building and demolition sites |
| IP Testing | NATA lab tested |
| Country of Sale | Australia |
| SKU | trappo10 |
| Colour | Orange |
| Brand | Transco |