Hager NT332C 32A three-pole miniature circuit breaker (MCB) with C tripping curve and 10kA breaking capacity. 3-module DIN rail design protects three-phase circuits against overload and short circuit. AS/NZS 60898 compliant.

Electrotraders USPs

Fast Shipping, Trusted by Government, Easy Returns, Free Shipping over $200


Description

Three-phase 32A protection, 10kA breaking.

The Hager NT332C is a 32A three-pole miniature circuit breaker (MCB) with a C tripping curve and 10kA breaking capacity, protecting three-phase circuits against overload and short circuit from a compact 3-module DIN rail body.

Key Features

  • Rated current: 32A, three-phase (3P)
  • C tripping curve (5–10x In)
  • 10kA breaking capacity (Icn) to IEC 60898-1
  • Rated voltage 415V AC, insulation voltage 500V
  • 3-module width (52.5mm) DIN rail mount
  • Accepts conductors 1–35mm² rigid, 1–25mm² flexible
  • Energy limiting class 3; IP20; 360° mounting
  • Compliant with AS/NZS 60898.1

Order now – fast dispatch on Hager circuit protection Australia-wide.

 

Why it Matters

Protects all three phases together.
The NT332C is a 32A three-pole miniature circuit breaker, protecting a three-phase circuit against both overload and short circuit and tripping automatically when either occurs. Its three linked poles switch and protect all three phases as one, a common choice for high-demand three-phase loads – motors, air-conditioning plant and machinery feeds – with a high 10kA breaking capacity for the fault levels found in commercial and industrial switchboards.

C curve for motor and mixed loads.
The C tripping characteristic trips on short circuit at 5 to 10 times rated current, the general-purpose curve suited to mixed resistive and inductive loads including the inrush of three-phase motors. Backed by a 10kA short-circuit breaking capacity to IEC 60898-1 and energy limiting class 3, the NT332C limits let-through energy during a fault to help protect downstream cabling and equipment.

Built for Australian switchboards.
At three modules (52.5mm) wide, 83mm high and 70mm deep, the NT332C clips onto standard 35mm DIN rail with 360° mounting flexibility, and its terminals take rigid conductors up to 35mm² at 2.8Nm. It is compliant with AS/NZS 60898.1, rated IP20, and operates from -25°C to 70°C to suit distribution boards and plant rooms across Australian conditions. Hager auxiliaries including the MZ201 auxiliary contact, MZ202 alarm contact and MZ203/MZ204 shunt trips are available.

Q: Is the Hager NT332C a three-phase breaker?
Yes. It is a 3-pole (3P) MCB that switches and protects all three phases of a 415V circuit together; it does not include a separate neutral pole.

Q: What does the C curve mean on the NT332C?
The C curve trips on short circuit at 5 to 10 times the rated current, making it the general-purpose characteristic for mixed resistive and inductive loads including motors.

Q: What is the difference between the NT332C (10kA) and a 6kA MCB?
10kA is the rated short-circuit breaking capacity, suited to higher-fault commercial and industrial boards; a 6kA breaker such as Hager's MSN range is used where fault levels are lower, typically residential and light commercial.

(hagmcb33210k)

Specifications

Electric current
Rated current32 A
Architecture
Type of pole3P
CurveC
Capacity
Number of modules3
Installation, mounting
Nominal tightening torque top terminal2,80 - 2,80 Nm
Nominal tightening torque down terminal2,80 - 2,80 Nm
Nominal tightening torque2,80 - 2,80 Nm
Type of bottom connection for modular devicesbiconnect
Type of top connection for modular devicesScrew terminal
360?ø mounting position possibleYes
Main electrical attributes
Rated short-circuit breaking capacity Icn AC according to IEC 60898-110 kA
Voltage
Rated operational voltage Ue415 - 415 V
Type voltage supplyAC
Rated insulation voltage Ui500 V
Rated impulse withstand voltage Uimp4000 V
Frequency
Frequency50 - 60 Hz
Safety
Ingress Protection (IP) classIP20
Use conditions
Degree of pollution according to IEC 60664 / IEC 60947-22
Class of energy limitation I^2t3
Air humidity protectionFor all climates
Operating temperature-25 - 70 DegC
Power
Total power loss under IN12,30 W
Connectivity
Type of connectionScrew terminal
Top connection alignment for modular devicesAligned terminal
Down connection alignment for modular devicesAligned terminal
Dimensions
Height83 mm
Width52,50 mm
Depth70 mm
Connection
Cross-section of input and output with screws, for massive conductors1 - 35 mm^2
Cross-section of input and output with screws, for flexible conductors1 - 25 mm^2
Cross-section of input with screws, for flexible conductors1 - 25 mm^2
Cross-section of input with screws, for massive conductors1 - 35 mm^2
SKU hagmcb33210k
Manfacturer Part Number NT332C
Barcode # 3250614807237
Brand Hager