Hager MSN140 Miniature Circuit Breaker MCB 40A 1 Pole C Curve 6kA 1 Module DIN Rail 240-415V

SKU: hagmcb1406k

Product Image Gallery

Product image thumbnail for SKU hagmcb1406k

Product Pricing

$5.19 (ex-GST)

$5.71 (inc-GST)

$5.71

$5.19

(inc-GST)
(ex-GST)

Stock and Availability

  • ⚫︎ Only 2 Left!

Hager MSN140 40A single-pole miniature circuit breaker (MCB) with C tripping curve and 6kA breaking capacity. Compact 1-module DIN rail design protects circuits against overload and short circuit. AS/NZS 60898 compliant.

Electrotraders USPs

Fast Shipping, Trusted by Government, Easy Returns, Free Shipping over $200


Description

40A protection for sub-mains.

The Hager MSN140 is a 40A single-pole miniature circuit breaker (MCB) with a C tripping curve and 6kA breaking capacity, protecting residential and light commercial circuits against overload and short circuit from a compact 1-module DIN rail body.

Key Features

  • Rated current: 40A, single pole (1P)
  • C tripping curve (5–10x In)
  • 6kA breaking capacity (Icn) to IEC 60898-1
  • Rated voltage 240–415V AC, insulation voltage 500V
  • Compact 1-module width (17.5mm) DIN rail mount
  • Accepts conductors 1–35mm² rigid, 1–25mm² flexible
  • Energy limiting class 3; IP20; 360° mounting
  • Compliant with AS/NZS 60898.1

Get yours today – fast dispatch on Hager circuit protection Australia-wide.

 

Why it Matters

For heavier household circuits.
The MSN140 is a 40A miniature circuit breaker, protecting a circuit against both overload and short circuit and tripping automatically when either occurs. A 40A rating suits sub-mains and the heaviest single final circuits – sub-boards, large appliances and high-demand feeds – and its 6kA breaking capacity suits the fault levels found in residential and light commercial switchboards.

C curve for motor and general loads.
The C tripping characteristic trips on short circuit at 5 to 10 times rated current, the general-purpose curve suited to mixed resistive and moderately inductive loads such as motor and general-purpose circuits. Backed by a 6kA short-circuit breaking capacity to IEC 60898-1 and energy limiting class 3, the MSN140 limits let-through energy during a fault to help protect downstream cabling.

Built for Australian switchboards.
At one module (17.5mm) wide, 83mm high and 70mm deep, the MSN140 clips onto standard 35mm DIN rail with 360° mounting flexibility, and its terminals take rigid conductors up to 35mm² at 2.8Nm. It is compliant with AS/NZS 60898.1, rated IP20, and operates from -25°C to 70°C to suit meter boxes, distribution boards and homes across Australian conditions. Hager auxiliaries including the MZ201 auxiliary contact, MZ202 alarm contact and MZ203/MZ204 shunt trips are available.

Q: What is the Hager MSN140 used for?
It is a 40A single-pole MCB, a common size for protecting sub-mains and heavy single circuits – such as sub-boards and large appliance feeds – against overload and short circuit in residential and light commercial boards.

Q: What does the C curve mean on the MSN140?
The C curve trips on short circuit at 5 to 10 times the rated current, making it the general-purpose characteristic for mixed resistive and moderately inductive loads.

Q: What is the difference between the MSN140 (6kA) and a 10kA MCB?
6kA is the rated short-circuit breaking capacity, suited to residential and light commercial boards; a 10kA breaker such as Hager's NT range is specified where fault levels are higher, typically in commercial and industrial installations.

(hagmcb1406k)

Specifications

Electric current
Rated current 40 A
Rated short-circuit breaking capacity Icn under 230 V AC according to IEC 60898-1 6 kA
Rated current -15DegC 51,25 A
Rated current -10DegC 50,19 A
Rated current -5DegC 49,18 A
Rated current at 0DegC 48,14 A
Rated current 5DegC 47,10 A
Rated current 10DegC 46,07 A
Rated current 15DegC 45,03 A
Rated current at 20DegC 43,99 A
Rated current 25DegC 42,95 A
Rated current 30DegC 41,92 A
Rated current 35DegC 40,88 A
Rated current at 40DegC 40 A
Rated current at 45DegC 38,80 A
Rated current at 50DegC 37,63 A
Rated current 55DegC 36,73 A
Rated current 60DegC 35,69 A
Rated current 65DegC 34,65 A
Rated current 70DegC 33,62 A
Architecture
Type of pole 1P
Curve C
Capacity
Number of modules 1
Installation, mounting
Nominal tightening torque top terminal 2,80 - 2,80 Nm
Nominal tightening torque down terminal 2,80 - 2,80 Nm
Nominal tightening torque 2,80 - 2,80 Nm
Type of bottom connection for modular devices biconnect
Type of top connection for modular devices Screw terminal
360?ø mounting position possible Yes
Main electrical attributes
Rated short-circuit breaking capacity Icn AC according to IEC 60898-1 6 kA
Voltage
Rated operational voltage Ue 240 - 415 V
Type voltage supply AC
Rated insulation voltage Ui 500 V
Rated impulse withstand voltage Uimp 4000 V
Frequency
Frequency 50 - 60 Hz
Connection
Cross-section of input and output with screws, for massive conductors 1 - 35 mm^2
Cross-section of input and output with screws, for flexible conductors 1 - 25 mm^2
Cross-section of input with screws, for flexible conductors 1 - 25 mm^2
Cross-section of input with screws, for massive conductors 1 - 35 mm^2
Cross-section flexible conductor 1 - 25 mm^2
Cross-section rigid conductor 1 - 35 mm^2
Safety
Ingress Protection (IP) class IP20
Use conditions
Degree of pollution according to IEC 60664 / IEC 60947-2 2
Class of energy limitation I^2t 3
Air humidity protection For all climates
Operating temperature -25 - 70 DegC
Power
Total power loss under IN 4,8 W
Connectivity
Type of connection Screw terminal
Top connection alignment for modular devices Aligned terminal
Down connection alignment for modular devices Aligned terminal
Dimensions
Height 83 mm
Width 17,50 mm
Depth 70 mm