Hager MSN110 10A single-pole miniature circuit breaker (MCB) with C tripping curve and 6kA breaking capacity. Compact 1-module DIN rail design protects circuits against overload and short circuit. AS/NZS 60898 compliant.

Electrotraders USPs

Fast Shipping, Trusted by Government, Easy Returns, Free Shipping over $200


Description

Dependable 10A circuit protection.

The Hager MSN110 is a 10A single-pole miniature circuit breaker (MCB) with a C tripping curve and 6kA breaking capacity, protecting residential and light commercial circuits against overload and short circuit from a compact 1-module DIN rail body.

Key Features

  • Rated current: 10A, single pole (1P)
  • C tripping curve (5–10x In)
  • 6kA breaking capacity (Icn) to IEC 60898-1
  • Rated voltage 240–415V AC, insulation voltage 500V
  • Compact 1-module width (17.5mm) DIN rail mount
  • Accepts conductors 1–35mm² rigid, 1–25mm² flexible
  • Energy limiting class 3; IP20; 360° mounting
  • Compliant with AS/NZS 60898.1

Buy online now – fast dispatch on Hager circuit protection Australia-wide.

 

Why it Matters

A workhorse lighting and sub-circuit breaker.
The MSN110 is a 10A miniature circuit breaker, protecting a circuit against both overload and short circuit and tripping automatically when either occurs. A 10A rating is one of the most common sizes on final sub-circuits – lighting and small power runs – and its 6kA breaking capacity suits the fault levels found in residential and light commercial switchboards.

C curve for general-purpose loads.
The C tripping characteristic trips on short circuit at 5 to 10 times rated current, the general-purpose curve suited to mixed resistive and moderately inductive loads such as lighting and power circuits. Backed by a 6kA short-circuit breaking capacity to IEC 60898-1 and energy limiting class 3, the MSN110 limits let-through energy during a fault to help protect downstream cabling.

Built for Australian switchboards.
At one module (17.5mm) wide, 83mm high and 70mm deep, the MSN110 clips onto standard 35mm DIN rail with 360° mounting flexibility, and its terminals take rigid conductors up to 35mm² at 2.8Nm. It is compliant with AS/NZS 60898.1, rated IP20, and operates from -25°C to 70°C to suit meter boxes, distribution boards and homes across Australian conditions. Hager auxiliaries including the MZ201 auxiliary contact, MZ202 alarm contact and MZ203/MZ204 shunt trips are available.

Q: What is the Hager MSN110 used for?
It is a 10A single-pole MCB, a common size for protecting lighting and small power sub-circuits against overload and short circuit in residential and light commercial boards.

Q: What does the C curve mean on the MSN110?
The C curve trips on short circuit at 5 to 10 times the rated current, making it the general-purpose characteristic for mixed resistive and moderately inductive loads.

Q: What is the difference between the MSN110 (6kA) and a 10kA MCB?
6kA is the rated short-circuit breaking capacity, suited to residential and light commercial boards; a 10kA breaker such as Hager's NT range is specified where fault levels are higher, typically in commercial and industrial installations.

(hagmcb1106k)

Specifications

Electric current
Rated current 10 A
Rated short-circuit breaking capacity Icn under 230 V AC according to IEC 60898-1 6 kA
Rated current -15DegC 12,8 A
Rated current -10DegC 12,5 A
Rated current -5DegC 12,2 A
Rated current at 0DegC 11,9 A
Rated current 5DegC 11,6 A
Rated current 10DegC 11,3 A
Rated current 15DegC 11 A
Rated current at 20DegC 10,7 A
Rated current 25DegC 10,4 A
Rated current 30DegC 10 A
Rated current 35DegC 9,8 A
Rated current at 40DegC 9,5 A
Rated current at 45DegC 9,2 A
Rated current at 50DegC 9 A
Rated current 55DegC 8,6 A
Rated current 60DegC 8,3 A
Rated current 65DegC 8 A
Rated current 70DegC 7,7 A
Architecture
Type of pole 1P
Curve C
Capacity
Number of modules 1
Installation, mounting
Nominal tightening torque top terminal 2,80 - 2,80 Nm
Nominal tightening torque down terminal 2,80 - 2,80 Nm
Nominal tightening torque 2,80 - 2,80 Nm
Type of bottom connection for modular devices biconnect
Type of top connection for modular devices Screw terminal
360?ø mounting position possible Yes
Main electrical attributes
Rated short-circuit breaking capacity Icn AC according to IEC 60898-1 6 kA
Voltage
Rated operational voltage Ue 240 - 415 V
Type voltage supply AC
Rated insulation voltage Ui 500 V
Rated impulse withstand voltage Uimp 4000 V
Frequency
Frequency 50 - 60 Hz
Connection
Cross-section of input and output with screws, for massive conductors 1 - 35 mm^2
Cross-section of input and output with screws, for flexible conductors 1 - 25 mm^2
Cross-section of input with screws, for flexible conductors 1 - 25 mm^2
Cross-section of input with screws, for massive conductors 1 - 35 mm^2
Cross-section flexible conductor 1 - 25 mm^2
Cross-section rigid conductor 1 - 35 mm^2
Safety
Ingress Protection (IP) class IP20
Use conditions
Degree of pollution according to IEC 60664 / IEC 60947-2 2
Class of energy limitation I^2t 3
Air humidity protection For all climates
Operating temperature -25 - 70 DegC
Power
Total power loss under IN 1,6 W
Connectivity
Type of connection Screw terminal
Top connection alignment for modular devices Aligned terminal
Down connection alignment for modular devices Aligned terminal
Dimensions
Height 83 mm
Width 17,50 mm
Depth 70 mm