ANDELI ADM100TC 3 Phase 100 Amp Kilowatt Hour Meter DIN Rail Digital

SKU: anddigtim100tc

Product Image Gallery

Product image thumbnail for SKU anddigtim100tc
Product image thumbnail for SKU anddigtim100tc
Product image thumbnail for SKU anddigtim100tc

Product Pricing

$179.85 (ex-GST)

$197.83 (inc-GST)

$197.83

$179.85

(inc-GST)
(ex-GST)

Stock and Availability

  • ⚫︎ Ships in 2-5 days

Electrotraders USPs

Fast Shipping, Trusted by Government, Easy Returns, Free Shipping over $200


Description

Three Phase. Digital LCD. DIN Rail. 7 Module. CT Input. 100A Energy Monitoring.

The Andeli ADM100TC is a three phase digital LCD kilowatt hour meter — a DIN rail mounted energy meter for accurately measuring and displaying active energy consumption in three phase electrical installations. Rated for use with current transformers (CT) up to 100A at 230/400V AC and 50/60Hz, Class 1.0 accuracy, compliant with EN62053-21. Seven DIN rail module width at 125mm. Sold individually.

  • Andeli ADM series — three phase digital LCD kilowatt hour (kWh) energy meter
  • CT input rated — for use with current transformers up to 100A
  • CT input variants: 1.5(6)A CT and 3(6)A CT secondary input
  • 230/400V AC, 50/60Hz
  • Class 1.0 accuracy — compliant with EN62053-21
  • LCD display — direct reading of active energy consumption in kWh
  • Analog type impulse register output with pulse output (terminals 7 and 8 — passive)
  • DIN rail mounting — 35mm symmetrical DIN rail
  • 7 module DIN rail width — 125mm body width
  • Three phase 4-wire (L1, L2, L3, N)
  • Rated impulse voltage: Uimp 10kV-1.2/50S
  • Power consumption: ≤2W/10VA per phase
  • Operating temperature: -10°C to +50°C
  • Note: some stock may be branded as Tesla — electrically identical product
  • Wiring instructions included

Order online now for fast dispatch Australia-wide.

 

Where the ADM100TC Fits — Three Phase CT Energy Monitoring for Commercial and Industrial Installations

A three phase kilowatt hour meter measures the total active energy consumed across all three phases of a three phase electrical installation — the fundamental measurement used for sub-metering of commercial tenancies, monitoring of three phase equipment such as motors, compressors, and HVAC systems, energy management reporting, and billing verification in commercial and industrial applications. The ADM100TC delivers that measurement in a 7-module DIN rail format, making it straightforward to install inside a standard three phase switchboard alongside the circuit protection devices serving the installation being metered.

The ADM100TC is a CT input meter — it is used in conjunction with external current transformers (CTs) sized to the circuit's full load current, with the CT secondary output feeding the meter. The meter accepts 1.5(6)A CT or 3(6)A CT secondary inputs. This CT input configuration allows the ADM100TC to accurately meter circuits operating at up to 100A — well beyond the range of direct connect meters — making it the correct specification for larger commercial and industrial three phase loads including main switchboard metering, larger motor circuits, HVAC plant metering, and commercial tenancy sub-metering on higher current three phase feeds.

The seven module 125mm width fits standard three phase switchboard DIN rail allocations without requiring a custom enclosure. The Class 1.0 accuracy rating and EN62053-21 compliance confirm the ADM100TC meets the technical requirements for commercial energy metering in Australian three phase installations. The passive pulse output on terminals 7 and 8 allows connection to an energy management system or data logger for remote monitoring where required — making the ADM100TC suitable for both standalone display applications and integrated energy management installations.

Q: What current transformers are required for the ADM100TC?
A: The ADM100TC accepts CT secondary inputs of 1.5(6)A CT or 3(6)A CT. External current transformers must be sized to match the full load current of the circuit being metered, with the CT secondary wired to the meter input terminals. Confirm the correct CT ratio with your electrical designer or installer before ordering.

Q: What is the difference between the ADM100TC and the ADM100TCR?
A: The ADM100TC is the LCD display CT input meter without remote communication. The ADM100TCR adds RS485 communication for remote data integration with energy management systems. Both are Class 1.0, EN62053-21 compliant, 7 module DIN rail CT input three phase meters.

Q: Is the Andeli ADM100TC suitable for Australian three phase commercial installations?
A: Yes. The ADM100TC is rated at 230/400V AC and 50/60Hz, complies with EN62053-21 at Class 1.0 accuracy, and mounts on a standard 35mm DIN rail in 7 module widths — compatible with standard Australian three phase commercial switchboard installations. External current transformers sized to the metered circuit current are required for installation.

Warranty

This product is backed by an extended manufacturer warranty - click here for details.

(anddigtim100tc)

Specifications

SKU anddigtim100tc
Brand Andeli

Shipping Calculator


Others Also Bought


More From This Category

GEN3 240V 25A Modular Contactor
$31.82 (ex-GST)
$35.00 (inc-GST)
GEN3 24V 25A Modular Contactor
$31.82 (ex-GST)
$35.00 (inc-GST)
Hager EHN010 Time Switch Daily Cycle
$89.37 (ex-GST)
$98.31 (inc-GST)
Hager EHN011 Time Switch Daily Cycle with reserve
$103.56 (ex-GST)
$113.92 (inc-GST)
Hager ESC125 25A 1 Pole 1NO Contactor
$47.50 (ex-GST)
$52.25 (inc-GST)
Hager ESC225 25A 2 Pole 2NO Contactor
$58.50 (ex-GST)
$64.35 (inc-GST)