4mm Twin and Earth TPS Electrical Cable White 2C+E 450/750V - 10m Cut
SKU: cabtwiear4.10m
Product Image Gallery
Product Pricing
$51.63 (ex-GST)
$56.79 (inc-GST)
$56.79
$51.63
Stock and Availability
- ⚫︎ 24 In Stock
4mm² twin and earth flat TPS cable, 2C+E 450/750V, V-90 PVC with white easy-tear sheath. AS/NZS 5000.2. Supplied as a single continuous 10m cut.
Electrotraders USPs
Description
Heavy-duty circuits, cut to the exact metre.
This 4mm² twin and earth TPS cable covers the higher-load runs that 2.5mm can't, without forcing you to buy a full drum. Order a single continuous cut in the length your job needs, or take the complete 100m roll.
Key Features
- 4 mm² twin and earth (2C+E) flat TPS construction with 7/0.85mm plain annealed copper conductors and a 2.5 mm² earth
- 450/750V rated with V-90 PVC insulation and a 3V-90 easy-tear white sheath for fast, clean stripping
- 90°C maximum conductor temperature and 30mm minimum bend radius
- Manufactured to AS/NZS 5000.2 for Australian fixed-wiring installations
- Cut lengths supplied as one continuous run — 10m, 20m, 25m, 30m, 40m or 50m — plus full 100m rolls
- Suitable for general wiring unenclosed, in conduit, or in underground ducts where not subject to mechanical damage
- Please choose cable type and length carefully — there are no refunds or exchanges on this product
- This product may attract a delivery surcharge to non-metropolitan areas
Add to cart and have it cut, coiled and on its way.
Why it Matters
Sized for the bigger loads
When hot water units, air conditioners and other higher-current final subcircuits push past what 2.5mm can carry — or voltage drop over a long run becomes the limiting factor — 4mm twin and earth is the step up Australian electricians reach for. Final conductor sizing should always be confirmed against AS/NZS 3008 for your installation method and run length.
Buy the run, not the drum
A full 100m roll makes no sense when the job needs 30m. Every cut length is supplied as one continuous piece, so there are no hidden joins — just the metres you ordered, ready to pull in.
Built to Australian standards
Manufactured to AS/NZS 5000.2 with plain annealed copper conductors, V-90 PVC insulation and a white easy-tear 3V-90 sheath that strips quickly on the tools.
What is 4mm twin and earth cable used for?
It's commonly run for higher-load final subcircuits such as hot water systems and air conditioners, where 2.5mm cable won't meet the current or voltage-drop requirements. Confirm sizing to AS/NZS 3008 for the installation method and run length.
Are the cut lengths supplied as one continuous piece?
Yes. Every cut length from 10m through to 50m is supplied as a single continuous run with no joins, and the 100m option comes as a complete roll.
Can I install this cable myself?
No. In Australia, fixed electrical wiring must be installed by a licensed electrician. This cable is sold for installation by qualified trades in accordance with AS/NZS 3000.
(cabtwiear4_p)
Specifications
| Product Details | |
| Product Type | Flat TPS Cable (Twin and Earth) |
| Configuration | 2 Core + Earth |
| Conductor Size (CSA) | 4 mm² |
| Earth Conductor Size | 2.5 mm² |
| Stranding | 7/0.85 mm |
| Nominal Conductor Diameter | 2.6 mm |
| Overall Dimensions | 14.1 mm x 6.5 mm |
| Electrical Properties | |
| Voltage Rating | 450/750 V |
| Conductor Resistance (DC) | 4.61 Ω/km |
| Maximum Conductor Temperature | 90°C |
| Construction | |
| Conductor | Plain annealed copper |
| Insulation | V-90 PVC, 0.8 mm thickness |
| Sheath | 3V-90 PVC, easy-tear |
| Sheath Colour | White |
| Core Colours | Red, Black, Green/Yellow (earth) |
| Minimum Bend Radius | 30 mm |
| Standards & Supply | |
| Standard | AS/NZS 5000.2 |
| UNSPSC Class | 26121600 |
| Cut Lengths | 10m, 20m, 25m, 30m, 40m, 50m (single continuous cut) |
| Roll Length | 100m |
| SKU | cabtwiear4_p |
| Brand | Generic |