GEN3 RCD2-40A 2 Pole 40A Safety Switch RCD Only 30mA Type A
SKU: genrcd240
Product Image Gallery
Product Pricing
$26.82 (ex-GST)
$29.50 (inc-GST)
$29.50
$26.82
Bulk Carton size
60Stock and Availability
- ⚫︎ Only 1 Left!
GEN3 2 Pole 40 Amp Safety Switch RCD/MCB 30mA
Electrotraders USPs
Description
Earth-leakage protection for a group of circuits.
The GEN3 RCD2-40A is a 2-pole, 40-amp residual current device (RCD) with a 30mA trip and Type A detection. It provides residual-current (earth-leakage) protection only, switching both the active and neutral conductors when it detects a fault to earth. It is commonly used as an RCD main switch, protecting a group of downstream circuits, with each of those circuits fitted with its own circuit breaker (MCB) for overload and short-circuit protection.
Key Features
- 2-pole, 40A residual current device (RCD)
- 30mA residual-current trip, Type A
- RCD only – provides earth-leakage protection, not overcurrent protection
- Switches both active and neutral on an earth fault
- Two module wide (approximately 36mm)
- Suited as an RCD main switch ahead of separate MCBs
- Body approximately 82 × 36 × 75mm
- Australian/NZ approval or compliance certificates held
- Interchangeable with other major brands
Buy now for fast dispatch across Australia.
RCD Only – What That Means
An RCD detects current leaking to earth, for example through a person or a fault, and disconnects the supply quickly to reduce the risk of electric shock. Being RCD only, the RCD2-40A does not provide overcurrent (overload or short-circuit) protection on its own, so it is paired with separate circuit breakers on the circuits it feeds. This differs from an RCBO, which combines RCD and MCB protection in a single device for one circuit.
A Practical RCD Main Switch
Rated 40A across two poles, the RCD2-40A is well suited to acting as a residual-current main switch for a sub-board or group of circuits. It switches both active and neutral, and its Type A classification detects both AC and pulsating DC residual currents. The 30mA trip threshold is the standard level used for protection against electric shock on general-purpose circuits.
Q: Does the GEN3 RCD2-40A protect against overload?
A: No. It is an RCD only, providing earth-leakage (residual current) protection. It does not provide overcurrent protection, so it must be used with separate circuit breakers on the downstream circuits.
Q: What is the difference between this RCD and an RCBO?
A: An RCBO combines RCD and MCB protection in one device for a single circuit. The RCD2-40A is RCD only, typically used as a main switch protecting a group of circuits that each have their own MCB.
Q: What does the RCD2-40A switch when it trips?
A: Being 2-pole, it disconnects both the active and neutral conductors when it detects an earth-leakage fault.
(genrcd240)
Specifications
| Product Specifications | |
| SKU | genrcd240 |
| Supplier Code | RCD2-40A |
| Product Type | Safety Switch RCD/MCB |
| Amps | 40Amp |
| Poles | 2 Pole |
| Voltage | 240 Volt |
| Dimensions | |
| Length (mm) | 82 |
| Width (mm) | 36 |
| Depth (mm) | 75 |
| Packaging Details | |
| Box Length (cm) | 8.5 |
| Box Width (cm) | 9 |
| Box Height (cm) | 4 |
| Box Qty | 1 |
| Box Weight (kg) | 0.24 |
| Materials | |
| Plastics | PCA18 virgin grade (No regrind) |
| Springs and Screw | 326 Stainless Steel |
| Brass Components | Brass internal components are greater than 85% copper. |
| Compliance and Approvals | |
| Approvals | Products have Australian/NZ Approval Certificates. |
| Compatibility | |
| Compatibility | Products are interchangeable with other major brands. |
| SKU | genrcd240 |
| Manfacturer Part Number | RCD2-40A |
| Colour | Grey |
| Brand | GEN3 |