Eureka LSSO10/C003-A 1 Pole RCBO 10A 10kA 30mA C Curve Type A Safety Switch
SKU: eurrcb110c
Product Image Gallery
Product Pricing
$62.73 (ex-GST)
$69.00 (inc-GST)
$69.00
$62.73
Stock and Availability
- ⚫︎ Ships in 2-5 days
Eureka LSSO10/C003-A 1 Pole Safety Switch RCBO 10 Amp 10kA RCD/MCB
Electrotraders USPs
Description
Eureka LSSO10/C003-A. 1 Pole RCBO. 10 Amp. 10kA. 30mA. C Curve. Type A. Safety Switch.
The Eureka LSSO10/C003-A is a 1 pole RCBO (Residual Current Breaker with Overcurrent protection) — combining earth leakage (RCD) and overcurrent (MCB) protection in a single 18mm DIN rail module. 10A rated current. 10kA breaking capacity. 30mA residual current sensitivity. C tripping curve. Type A earth leakage detection. Conforms to AS/NZS 61009. For installation in Eureka distribution boards and standard DIN rail switchboards. Must be installed by a licensed electrician.
- LSSO10/C003-A — 1 Pole RCBO, 10A, 10kA, 30mA, C Curve, Type A
- Rated current: 10A
- Tripping curve: C curve — suits resistive and general load circuits
- Breaking capacity: 10kA
- Residual current sensitivity: 30mA — personnel protection
- Earth leakage detection: Type A — detects sinusoidal AC and pulsating DC residual currents
- Poles: 1 pole
- Rated voltage: 240V AC
- Frequency: 50Hz
- Module width: 18mm — 1 DIN module
- Mounting: DIN rail
- Standard: AS/NZS 61009
- Suits Eureka distribution boards and standard DIN rail switchboards
- Provides combined protection against earth leakage, overload, and short circuit
- Must be installed by a licensed electrician
- Sold individually
Order online now — fast dispatch Australia-wide.
About RCBOs — Combined Safety Switch and Circuit Breaker
An RCBO (Residual Current Breaker with Overcurrent protection) combines the functions of a safety switch (RCD) and a circuit breaker (MCB) into a single device — providing protection against earth leakage faults, overload currents, and short circuits in a single DIN rail module. This makes the RCBO the preferred choice for individual circuit protection in modern distribution boards, replacing the need for a separate RCD and MCB for each protected circuit.
The 30mA residual current sensitivity is the standard level required for personnel protection in Australian electrical installations under AS/NZS 3000 — tripping within a defined time when earth leakage current reaches 30mA, before it can cause serious injury. Type A detection covers both sinusoidal AC residual currents and pulsating DC residual currents, providing broader protection than Type AC devices — suited to circuits supplying modern electronic equipment, variable speed drives, and switch-mode power supplies.
The C tripping curve suits general resistive and inductive load circuits in residential, commercial, and light industrial applications. The LSSO10/C003-A is part of the Eureka LSSO range — 10kA rated, 18mm wide, DIN rail mounted — and is compatible with the Eureka distribution board and enclosure system. Conforms to AS/NZS 61009 and must be installed by a licensed electrician in accordance with AS/NZS 3000.
Q: What is an RCBO and how does it differ from an RCD or MCB?
A: An RCBO combines an RCD (safety switch) and an MCB (circuit breaker) in one device — providing earth leakage, overload, and short circuit protection in a single 18mm DIN module. An RCD alone provides earth leakage protection only. An MCB alone provides overload and short circuit protection only.
Q: What does 30mA sensitivity mean?
A: The RCBO will trip when earth leakage current reaches 30mA — the standard sensitivity level required for personnel protection in Australian electrical installations per AS/NZS 3000.
Q: What is Type A earth leakage detection?
A: Type A detects both sinusoidal AC and pulsating DC residual currents — suitable for circuits supplying electronic equipment, computers, variable speed drives, and appliances with switch-mode power supplies. Type AC detects sinusoidal AC only.
Q: What is the C curve and what loads does it suit?
A: The C tripping curve suits general resistive and inductive load circuits — lighting, power points, appliances, and general wiring in residential and commercial installations.
Q: What is the breaking capacity of the LSSO10/C003-A?
A: The LSSO10/C003-A has a 10kA breaking capacity — suited to circuits where prospective fault current may reach up to 10,000A.
Q: Does the LSSO10/C003-A need to be installed by a licensed electrician?
A: Yes — installation of RCBOs in a distribution board must be carried out by a licensed electrician in accordance with AS/NZS 3000 Wiring Rules.
(eurrcb110c)
Specifications
| Product | |
| Part Number | LSSO10/C003-A |
| Brand | Eureka (LS Switchgear) |
| Type | RCBO — Residual Current Breaker with Overcurrent Protection |
| Electrical | |
| Rated Current (In) | 10A |
| Rated Voltage | 240V AC |
| Frequency | 50Hz |
| Breaking Capacity (Icn) | 10kA |
| Residual Current Sensitivity (IΔn) | 30mA |
| Tripping Curve | C curve |
| Earth Leakage Detection Type | Type A — AC sinusoidal and pulsating DC |
| Mechanical | |
| Poles | 1 Pole |
| Module Width | 18mm — 1 DIN module |
| Mounting | DIN rail |
| Compliance | |
| Standard | AS/NZS 61009 |
| Installation | |
| Installation Requirement | Must be installed by a licensed electrician — AS/NZS 3000 |
| Compatible With | Eureka distribution boards, standard DIN rail switchboards |
| Supply | |
| Supply | Sold individually |
| Country of Sale | Australia |
| SKU | eurrcb110c |
| Manfacturer Part Number | LSSO10/C003-A |
| Colour | Grey |
| Brand | Eureka |
Shipping Calculator
Others Also Bought
More From This Category