GEN3 RCD4-40A 4 Pole 40A Safety Switch RCD Only 30mA Type A

SKU: genrcd440

Product Image Gallery

Product image thumbnail for SKU genrcd440
Product image thumbnail for SKU genrcd440
 Download Data Sheet

Product Pricing

$36.18 (ex-GST)

$39.80 (inc-GST)

$39.80

$36.18

(inc-GST)
(ex-GST)

Bulk Carton size

 30

Stock and Availability

  • ⚫︎ Only 1 Left!

GEN3 4 Pole 40 Amp Safety Switch RCD/MCB 30mA

Electrotraders USPs

Fast Shipping, Trusted by Government, Easy Returns, Free Shipping over $200


Description

Three-phase earth-leakage protection for a switchboard.

The GEN3 RCD4-40A is a 4-pole, 40-amp residual current device (RCD) rated 415V, with a 30mA trip and Type A detection. It provides residual-current (earth-leakage) protection only, switching all three active conductors and the neutral when it detects a fault to earth. It is commonly used as a three-phase RCD main switch, protecting a group of downstream circuits, with each of those circuits fitted with its own circuit breaker (MCB) for overload and short-circuit protection.

Key Features

  • 4-pole, 40A residual current device (RCD)
  • 415V three-phase
  • 30mA residual-current trip, Type A
  • RCD only – provides earth-leakage protection, not overcurrent protection
  • Switches three actives and neutral on an earth fault
  • Four module wide (approximately 72mm)
  • Suited as a three-phase RCD main switch ahead of separate MCBs
  • Body approximately 82 × 72 × 75mm
  • Australian/NZ approval or compliance certificates held
  • Interchangeable with other major brands

Add to cart for fast dispatch across Australia.

 

RCD Only – What That Means

An RCD detects current leaking to earth, for example through a person or a fault, and disconnects the supply quickly to reduce the risk of electric shock. Being RCD only, the RCD4-40A does not provide overcurrent (overload or short-circuit) protection on its own, so it is paired with separate circuit breakers on the circuits it feeds. This differs from an RCBO, which combines RCD and MCB protection in a single device.

A Three-Phase RCD Main Switch

Rated 40A across four poles at 415V, the RCD4-40A is well suited to acting as a residual-current main switch for a three-phase sub-board or group of circuits. It switches all three active conductors and the neutral, and its Type A classification detects both AC and pulsating DC residual currents. The 30mA trip threshold is the standard level used for protection against electric shock on general-purpose circuits.

Q: Does the GEN3 RCD4-40A protect against overload?
A: No. It is an RCD only, providing earth-leakage (residual current) protection. It does not provide overcurrent protection, so it must be used with separate circuit breakers on the downstream circuits.

Q: Is the RCD4-40A for single-phase or three-phase?
A: Three-phase. It is a 4-pole, 415V device, switching three active conductors and the neutral. For single-phase, the 2-pole RCD2-40A is the equivalent.

Q: What does the RCD4-40A switch when it trips?
A: Being 4-pole, it disconnects all three active conductors and the neutral when it detects an earth-leakage fault.

(genrcd440)

Specifications

Product Specifications
SKU genrcd440
Supplier Code RCD4-40A
Product Type Safety Switch RCD/MCB
Amps 40Amp
Poles 4 Pole
Voltage 415 Volt
Dimensions
Length (mm) 82
Width (mm) 72
Depth (mm) 75
Packaging Details
Box Length (cm) 8.5
Box Width (cm) 9
Box Height (cm) 7.2
Box Qty 1
Box Weight (kg) 0.37
Materials
Plastics PCA18 virgin grade (No regrind)
Springs and Screw 327 Stainless Steel
Brass Components Brass internal components are greater than 85% copper.
Compliance and Approvals
Approvals Products have Australian/NZ Approval Certificates.
Compatibility
Compatibility Products are interchangeable with other major brands.
SKU genrcd440
Manfacturer Part Number RCD4-40A
Brand GEN3