Eureka LSSO25/C003-A 1 Pole Safety Switch RCBO 25 Amp 10kA RCD/MCB

Electrotraders USPs

Fast Shipping, Trusted by Government, Easy Returns, Free Shipping over $200


Description

Eureka LSSO25/C003-A. 1 Pole RCBO. 25 Amp. 10kA. 30mA. C Curve. Type A. Safety Switch.

The Eureka LSSO25/C003-A is a 1 pole RCBO (Residual Current Breaker with Overcurrent protection) — combining earth leakage (RCD) and overcurrent (MCB) protection in a single 18mm DIN rail module. 25A rated current. 10kA breaking capacity. 30mA residual current sensitivity. C tripping curve. Type A earth leakage detection. Conforms to AS/NZS 61009. For installation in Eureka distribution boards and standard DIN rail switchboards. Must be installed by a licensed electrician.

  • LSSO25/C003-A — 1 Pole RCBO, 25A, 10kA, 30mA, C Curve, Type A
  • Rated current: 25A
  • Tripping curve: C curve — suits resistive and general load circuits
  • Breaking capacity: 10kA
  • Residual current sensitivity: 30mA — personnel protection
  • Earth leakage detection: Type A — detects sinusoidal AC and pulsating DC residual currents
  • Poles: 1 pole
  • Rated voltage: 240V AC
  • Frequency: 50Hz
  • Module width: 18mm — 1 DIN module
  • Mounting: DIN rail
  • Standard: AS/NZS 61009
  • Suits Eureka distribution boards and standard DIN rail switchboards
  • Provides combined protection against earth leakage, overload, and short circuit
  • Must be installed by a licensed electrician
  • Sold individually

Order online now — fast dispatch Australia-wide.

 

About RCBOs — Combined Safety Switch and Circuit Breaker

An RCBO (Residual Current Breaker with Overcurrent protection) combines the functions of a safety switch (RCD) and a circuit breaker (MCB) into a single device — providing protection against earth leakage faults, overload currents, and short circuits in a single DIN rail module. This makes the RCBO the preferred choice for individual circuit protection in modern distribution boards, replacing the need for a separate RCD and MCB for each protected circuit.

The 30mA residual current sensitivity is the standard level required for personnel protection in Australian electrical installations under AS/NZS 3000 — tripping within a defined time when earth leakage current reaches 30mA, before it can cause serious injury. Type A detection covers both sinusoidal AC residual currents and pulsating DC residual currents, providing broader protection than Type AC devices — suited to circuits supplying modern electronic equipment, variable speed drives, and switch-mode power supplies.

The C tripping curve suits general resistive and inductive load circuits in residential, commercial, and light industrial applications. At 25A, the LSSO25/C003-A suits higher-load circuits such as electric ovens, hot water systems, air conditioning units, and dedicated sub-circuit feeds. The LSSO25/C003-A is part of the Eureka LSSO range — 10kA rated, 18mm wide, DIN rail mounted — and is compatible with the Eureka distribution board and enclosure system. Conforms to AS/NZS 61009 and must be installed by a licensed electrician in accordance with AS/NZS 3000.

Q: What is an RCBO and how does it differ from an RCD or MCB?
A: An RCBO combines an RCD (safety switch) and an MCB (circuit breaker) in one device — providing earth leakage, overload, and short circuit protection in a single 18mm DIN module. An RCD alone provides earth leakage protection only. An MCB alone provides overload and short circuit protection only.

Q: What does 30mA sensitivity mean?
A: The RCBO will trip when earth leakage current reaches 30mA — the standard sensitivity level required for personnel protection in Australian electrical installations per AS/NZS 3000.

Q: What is Type A earth leakage detection?
A: Type A detects both sinusoidal AC and pulsating DC residual currents — suitable for circuits supplying electronic equipment, computers, variable speed drives, and appliances with switch-mode power supplies.

Q: What is the C curve and what loads does it suit?
A: The C tripping curve suits general resistive and inductive load circuits — ovens, hot water systems, air conditioning, and dedicated appliance circuits in residential and commercial installations.

Q: What is the breaking capacity of the LSSO25/C003-A?
A: The LSSO25/C003-A has a 10kA breaking capacity — suited to circuits where prospective fault current may reach up to 10,000A.

Q: Does the LSSO25/C003-A need to be installed by a licensed electrician?
A: Yes — installation of RCBOs in a distribution board must be carried out by a licensed electrician in accordance with AS/NZS 3000 Wiring Rules.

(eurrcb125c)

Specifications

Product
Part Number LSSO25/C003-A
Brand Eureka (LS Switchgear)
Type RCBO — Residual Current Breaker with Overcurrent Protection
Electrical
Rated Current (In) 25A
Rated Voltage 240V AC
Frequency 50Hz
Breaking Capacity (Icn) 10kA
Residual Current Sensitivity (IΔn) 30mA
Tripping Curve C curve
Earth Leakage Detection Type Type A — AC sinusoidal and pulsating DC
Mechanical
Poles 1 Pole
Module Width 18mm — 1 DIN module
Mounting DIN rail
Compliance
Standard AS/NZS 61009
Installation
Installation Requirement Must be installed by a licensed electrician — AS/NZS 3000
Compatible With Eureka distribution boards, standard DIN rail switchboards
Supply
Supply Sold individually
Country of Sale Australia
SKU eurrcb125c
Manfacturer Part Number LSSO25/C003-A
Colour Grey
Brand Eureka