Transco ENC02 2 Way DIN Rail Enclosure MCB RCD RCBO Timer IP30
SKU: tracircov2
Product Image Gallery
Product Pricing
$3.00 (ex-GST)
$3.30 (inc-GST)
$3.30
$3.00
Stock and Availability
- ⚫︎ 41 In Stock
2 Pole Enclosure for Circuit Breakers, RCDs, RCBOs, Timers, Contactors, DIN
Electrotraders USPs
Description
2 Way DIN Rail Enclosure. Compact. Circuit Protection Ready.
The Transco ENC02 is a 2 way DIN rail enclosure — housing for two DIN rail mounted circuit protection or control devices including circuit breakers, RCDs, RCBOs, timers, and contactors. Rated up to 63A at 240/415V AC, with a UV and fire resistant ABS body. A compact two-position solution for applications where a pair of protection or control devices need a dedicated, clean housing without requiring a full multi-way switchboard. Sold as enclosure only — devices sold separately.
- Transco — 2 way DIN rail enclosure for circuit breakers, RCDs, RCBOs, timers, contactors
- UV and fire resistant ABS construction
- 2 DIN rail module capacity
- Suits MCBs, RCBOs, RCDs, timers, contactors, and standard DIN rail mounted devices
- Rated up to 63A at 240/415V AC, 50/60Hz
- IP30 ingress protection
- Dimensions: L52 mm x W130 mm x H60 mm
- Standard: IEC60439-3
- Also available in 1, 4, 6, 8, 12, and 18 way configurations
- Enclosure only — devices sold separately
Order online now for fast dispatch Australia-wide.
Where the ENC02 Fits — Two Device Circuit Protection in a Clean Enclosure
The ENC02 provides two DIN rail module positions in a compact L52mm enclosure — the right specification for applications where a pair of circuit protection or control devices need dedicated housing. Common configurations include a main switch plus a single circuit breaker, a double pole MCB, an RCBO plus a timer, or a contactor paired with a control device. The two-position format gives enough capacity for a simple but complete control or protection circuit without the bulk of a larger switchboard.
The Neto product name for this enclosure specifically references timers and contactors alongside the standard circuit protection devices — the ENC02's two positions make it particularly well suited to small timer and contactor control circuits where the enclosure needs to house both the switching device and a control element. The UV and fire resistant ABS body provides the structural integrity and material safety required for electrical enclosures, and the IP30 rating makes it suitable for indoor and sheltered installations. For outdoor or exposed installations, the weatherproof SB range is the appropriate specification.
The ENC02 is the 2 way option in the Transco enclosure range — the step up from the single position ENC01. The same enclosure is available in 4 way (ENC04), 6 way (ENC06), 8 way (ENC08), 12 way (ENC12), and 18 way (ENC18) for installations requiring more module positions. All variants share the same 130mm width, 60mm height, UV and fire resistant ABS construction, and IEC60439-3 standard compliance.
Q: What devices are compatible with the Transco ENC02 enclosure?
A: The ENC02 accommodates any standard DIN rail mounted devices up to 2 module widths total — including MCBs, RCBOs, RCDs, timers, contactors, main switches, and other standard DIN rail devices. Devices are sold separately. Confirm the module width of specific devices before ordering to ensure they fit within the 2 way capacity.
Q: Can timers and contactors be installed in the Transco ENC02?
A: Yes. The ENC02 accepts any standard DIN rail mounted device including timers and contactors, provided the total module width of all installed devices does not exceed 2 modules. This makes it suitable for simple timer-controlled lighting circuits and small contactor control applications.
Q: What is the IP30 rating of the Transco ENC02 enclosure?
A: IP30 means the ENC02 provides protection against solid objects greater than 2.5mm in diameter. It is not rated for water ingress and is suitable for indoor and sheltered installations only. For outdoor or exposed locations, the Transco weatherproof switchboard range (IP55) is the appropriate specification.
(tracircov2)
Specifications
| Product | |||||||||||||||||||||||||
| Brand | Transco | ||||||||||||||||||||||||
| Model / Product Code | ENC02 | ||||||||||||||||||||||||
| Description | 2 Way DIN Rail Enclosure for Circuit Breakers, RCDs, RCBOs, Timers, Contactors | ||||||||||||||||||||||||
| Electrical Ratings | |||||||||||||||||||||||||
| Maximum Current Rating | 63A | ||||||||||||||||||||||||
| Voltage | 240/415V | ||||||||||||||||||||||||
| Frequency | 50/60Hz | ||||||||||||||||||||||||
| Current Type | AC | ||||||||||||||||||||||||
| DIN Rail Module Capacity | 2 modules | ||||||||||||||||||||||||
| Compatible Devices | MCBs, RCBOs, RCDs, timers, contactors, standard DIN rail devices | ||||||||||||||||||||||||
| Ingress Protection | |||||||||||||||||||||||||
| IP Rating | IP30 | ||||||||||||||||||||||||
| Suitable For | Indoor and sheltered installations only | ||||||||||||||||||||||||
| Physical — ENC02 | |||||||||||||||||||||||||
| Length | 52 mm | ||||||||||||||||||||||||
| Width | 130 mm | ||||||||||||||||||||||||
| Height | 60 mm | ||||||||||||||||||||||||
| Materials & Construction | |||||||||||||||||||||||||
| Body Material | ABS — UV and fire resistant | ||||||||||||||||||||||||
| Installation | |||||||||||||||||||||||||
| Contents | Enclosure only — devices sold separately | ||||||||||||||||||||||||
| Variants Available | |||||||||||||||||||||||||
|
|||||||||||||||||||||||||
| Compliance & Standards | |||||||||||||||||||||||||
| Standard | IEC60439-3 | ||||||||||||||||||||||||
| Country of Sale | Australia | ||||||||||||||||||||||||
| SKU | tracircov2 |